Remote probe microphone measurement to verify hearing aid performance

被引:23
|
作者
Ferrari, Deborah Viviane [1 ]
Alvarez Bernardez-Braga, Gabriela Rosito [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Bauru, Dept Speech Language Pathol & Audiol, Bauru, SP, Brazil
关键词
RELIABILITY;
D O I
10.1258/jtt.2009.003005
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
We assessed the feasibility of obtaining probe microphone measurements of hearing aids at a distance. Face-to-face and remote probe microphone measurements were carried out in 60 hearing aid users (mean age 67 yrs) with uni- or bilateral hearing losses (105 ears tested). The participant and a facilitator were located in a room equipped with a probe microphone system interfaced to a PC. Desktop videoconferencing and application sharing was used to allow an audiologist in another room to instruct the facilitator and control the equipment via the LAN. There were significant correlations between face-to-face and remote real ear unaided response (REUR), aided response (REAR) and insertion gain (REIG) at seven discrete frequencies from 250 to 6000 Hz. Differences between face-to-face and remote responses were within the reported variability for probe microphone measurements themselves. The results show that remote probe microphone measurements are feasible and might improve the quality of public hearing aid services and professional training in Brazil.
引用
收藏
页码:122 / 124
页数:3
相关论文
共 50 条
  • [41] Measurement of hearing aid internal noise
    Lewis, James D.
    Goodman, Shawn S.
    Bentler, Ruth A.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 127 (04): : 2521 - 2528
  • [42] Development of the Hearing Aid Measurement System
    Homton, A.
    Umchid, S.
    Leeudomwong, S.
    Thongboon, A.
    Kongthavorn, P.
    Juntarapaso, Y.
    Plangsaengmas, V.
    6TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2013), 2013,
  • [43] MICROPHONE PROBE FOR SOUND MEASUREMENT IN FLAMES AND INACCESSIBLE PLACES
    KNEZEK, RA
    FAULKNER, LL
    MORAN, MJ
    APPLIED ACOUSTICS, 1977, 10 (02) : 79 - 83
  • [44] Impact of compression and hearing aid style on directional hearing aid benefit and performance
    Ricketts, T
    Lindley, G
    Henry, P
    EAR AND HEARING, 2001, 22 (04): : 348 - 361
  • [45] DIFFERENCES IN HEARING AID PERFORMANCE - ARSENIC RELATED TO CLINICAL HEARING AID EVALUATIONS
    HAUG, O
    BACCARO, P
    GUILFORD, FR
    ARCHIVES OF OTOLARYNGOLOGY, 1971, 93 (02): : 183 - &
  • [46] Use of forward pressure level to minimize the influence of acoustic standing waves during probe-microphone hearing-aid verification
    McCreery, Ryan W.
    Pittman, Andrea
    Lewis, James
    Neely, Stephen T.
    Stelmachowicz, Patricia G.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2009, 126 (01): : 15 - 24
  • [47] BINAURAL HEARING-AID USE AND THE HEARING MEASUREMENT SCALE
    CHUNG, SM
    STEPHENS, SDG
    IRCS MEDICAL SCIENCE-BIOCHEMISTRY, 1983, 11 (08): : 721 - 722
  • [48] An objective measure for selecting microphone modes in OMNI/DIR hearing aid circuits
    Grant, Ken W.
    Elhilali, Mounya
    Shamma, Shihab A.
    Walden, Brian E.
    Surr, Rauna K.
    Cord, Mary T.
    Summers, Van
    EAR AND HEARING, 2008, 29 (02): : 199 - 213
  • [49] HEAD-BAFFLE EFFECT FOR DIFFERENT HEARING-AID MICROPHONE LOCATIONS
    LYBARGER, SF
    BARRON, FE
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1965, 38 (05): : 922 - &
  • [50] Speech Enhancement Algorithm Based on Microphone Array and Lightweight CRN for Hearing Aid
    Xi, Ji
    Xu, Zhe
    Zhang, Weiqi
    Zhao, Li
    Xie, Yue
    ELECTRONICS, 2024, 13 (22)