Optimization Design for Receiving Coil with Novel Structure Based on Mutual Coupling Model in Wireless Power Transmission for Capsule Endoscope

被引:8
作者
Kuang, Shuai [1 ,2 ]
Yan, Guozheng [1 ,2 ]
Wang, Zhiwu [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Precise Med Engn & Intelligent Elect Microsy, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Inst Med Robot, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
biomedical micro devices; gastrointestinal diseases; noninvasive endoscope; wireless capsule endoscope (WCE); wireless power transmission; TRANSFER SYSTEM; ANTENNA;
D O I
10.3390/en13236460
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wireless capsule endoscope (WCE) is a promising technology for noninvasive and painless imaging detection on gastrointestinal (GI) diseases. On the other hand, conventional endoscopes with wires could discomfort patients and cause them to vomit and aerosolize coronavirus if the patients are infected with COVID-19. However, there stands a technical bottleneck on power supply for the WCE. With the help of wireless power transmission technology, a hollow receiving coil (RC) is proposed to supply sufficient power and also minimize the size of WCE. A model on mutual inductance between transmitting and receiving coils is proposed to evaluate receiving power when the RC is in a different position and direction of patient's GI tract. Based on the model, an optimal RC is built to obtain sufficient and stable power. Measurement of mutual inductance with the optimal RC validates high accuracy of the proposed model. The standard deviation of receiving power is very low. WCE with optimum RC gets sufficient power and captures images stably in live pig's intestine tract. Additionally, the model is little affected by biological tissues. It ensures reliable performance of WCE and makes popular clinical application of WCE possible, which is also a relief to reduce epidemics like COVID-19.
引用
收藏
页数:14
相关论文
共 28 条
[1]   An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope [J].
Basar, Md. Rubel ;
Ahmad, Mohd Yazed ;
Cho, Jongman ;
Ibrahim, Fatimah .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (10) :7772-7781
[2]   An improved resonant wireless power transfer system with optimum coil configuration for capsule endoscopy [J].
Basar, Md. Rubel ;
Ahmad, Mohd Yazed ;
Cho, Jongman ;
Ibrahim, Fatimah .
SENSORS AND ACTUATORS A-PHYSICAL, 2016, 249 :207-216
[3]   Multiplexed Supply of a MISO Wireless Power Transfer System for Battery-Free Wireless Sensors [J].
Bouattour, Ghada ;
Elhawy, Mohamed ;
Naifar, Slim ;
Viehweger, Christian ;
Derbel, Houda Ben Jmaa ;
Kanoun, Olfa .
ENERGIES, 2020, 13 (05)
[4]   Determining the Position and Orientation of In-Body Medical Instruments Using Near-Field Magnetic Field Mapping [J].
Cavlu, Vedat ;
Brennan, Paul .
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2020, 4 (01) :10-16
[5]   Numerical Calculation and Experimental Verification of Inductance and Critical Current Characteristics in a Solenoidal SMES Magnet [J].
Feng, Ying Jun ;
Chen, Xiao Yuan ;
Chen, Yu ;
Li, Meng Yao ;
Zeng, Lei ;
Xie, Qi .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
[6]   Design and Implementation of a Clamper-Based and Motor-Driven Capsule Robot Powered by Wireless Power Transmission [J].
Gao, Jinyang ;
Yan, Guozheng .
IEEE ACCESS, 2019, 7 :138151-138161
[7]   A Novel Power Management Circuit Using a Super-Capacitor Array for Wireless Powered Capsule Robot [J].
Gao, Jinyang ;
Yan, Guozheng .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2017, 22 (03) :1444-1455
[8]   Design, Implementation, and Fundamental Limits of Image and RF Based Wireless Capsule Endoscopy Hybrid Localization [J].
Geng, Yishuang ;
Pahlavan, Kaveh .
IEEE TRANSACTIONS ON MOBILE COMPUTING, 2016, 15 (08) :1951-1964
[9]   Dual-Side Independent Switched Capacitor Control for Wireless Power Transfer with Coplanar Coils [J].
Han, Chong ;
Zhang, Bo ;
Fang, Zanfeng ;
Qiu, Dongyuan ;
Chen, Yanfeng ;
Xiao, Wenxun .
ENERGIES, 2018, 11 (06)
[10]   A wirelessly powered expanding-extending robotic capsule endoscope for human intestine [J].
He, Shu ;
Yan, Guo-Zheng ;
Ke, Quan ;
Wang, Zhi-Wu ;
Chen, Wen-Wen .
INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (06) :1075-1084