Development and Characterization of a Wireless Mouse-Based Spirometer

被引:7
作者
Bagchi, Surajit [1 ]
Sengupta, Subhabrata [2 ]
Mandal, Sanjoy [3 ]
机构
[1] Heritage Inst Technol, Appl Elect & Instrumentat Engn Dept, Kolkata, India
[2] Heritage Inst Technol, Dept Biotechnol, Kolkata, India
[3] Indian Sch Mines, Dhanbad, Jharkhand, India
关键词
COPD; CRPD; displacement sensor; predictor equations; respiratory indices; spirometer; LUNG-FUNCTION; PREDICTION EQUATIONS; PULMONARY-FUNCTION; REFERENCE VALUES; VOLUME;
D O I
10.1109/JSEN.2017.2664889
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
One of the biggest challenges, regarding the diagnosis and effective management of life-threatening respiratory diseases, is the inadequate access to diagnostic devices like spirometer. The available good-quality commercial spirometers are too expensive (typical spirometers cost $1000-$2500) to afford by the common people in most of the developing countries. This paper presents the development, metrological characteristics, performance evaluation of a cost-effective ($276), easy-to-operate, and electrical hazard-free spirometer using the wireless optical mouse as a novel displacement-sensing element. Computational algorithms generate graphical patterns and numerical values of various respiratory performance indices. The device obtained test results and statistical analysis using Bland-Altman technique show a reasonable match between the standard spirometer and established anthropometry and ethnicity-dependent predictor equations. The device can successfully discriminate the chronic obstructive and restrictive pulmonary diseases and confirms its prospect for clinical uses.
引用
收藏
页码:2065 / 2073
页数:9
相关论文
共 32 条
[1]  
Aggarwal AN, 2005, INDIAN J MED RES, V122, P153
[2]  
[Anonymous], 2015, PULMONARY FUNCTION T
[3]  
[Anonymous], 1988, 3 NATL HLTH NUTR EXA
[4]   Statistics in clinical research: Important considerations [J].
Barkan, Howard .
ANNALS OF CARDIAC ANAESTHESIA, 2015, 18 (01) :74-82
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Brown D., 2006, WASHINGTON POST
[7]   A differential pressure approach to spirometry [J].
Carta, R. ;
Turgis, D. ;
Hermans, B. ;
Jourand, P. ;
Onclin, R. ;
Puers, R. .
2007 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE, 2007, :5-8
[8]   SPIROMETRIC STANDARDS FOR NON-SMOKERS AND SMOKERS OF INDIA (EASTERN REGION) [J].
CHATTERJEE, S ;
NAG, SK ;
DEY, SK .
JAPANESE JOURNAL OF PHYSIOLOGY, 1988, 38 (03) :283-298
[9]   PULMONARY-FUNCTION STUDIES IN HEALTHY NONSMOKING WOMEN OF CALCUTTA [J].
CHATTERJEE, S ;
SAHA, D .
ANNALS OF HUMAN BIOLOGY, 1993, 20 (01) :31-38
[10]   THE DEVELOPING WORLD IS POORER THAN WE THOUGHT, BUT NO LESS SUCCESSFUL IN THE FIGHT AGAINST POVERTY [J].
Chen, Shaohua ;
Ravallion, Martin .
QUARTERLY JOURNAL OF ECONOMICS, 2010, 125 (04) :1577-1625