Effect of a Cast on Short-Term Reproducibility and Bone Parameters Obtained from HR-pQCT Measurements at the Distal End of the Radius

被引:15
作者
de Jong, Joost J. A. [1 ,2 ,4 ]
Arts, Jacobus J. [1 ,3 ,5 ]
Meyer, Ursina [1 ,2 ,4 ,6 ]
Willems, Paul C. [1 ,3 ,5 ]
Geusens, Piet P. [1 ,3 ,4 ]
van den Bergh, Joop P. W. [1 ,2 ,4 ,7 ,8 ]
van Rietbergen, Bert [1 ]
机构
[1] Eindhoven Univ Technol, Fac Biomed Engn, POB 513, NL-5600 MB Eindhoven, Netherlands
[2] Maastricht Univ, Res Sch NUTRIM, NL-6200 MD Maastricht, Netherlands
[3] Maastricht Univ, CAPHRI, NL-6200 MD Maastricht, Netherlands
[4] Maastricht Univ, Med Ctr, Dept Rheumatol, NL-6200 MD Maastricht, Netherlands
[5] Maastricht Univ, Med Ctr, Dept Orthopaed Surg, NL-6200 MD Maastricht, Netherlands
[6] Maastricht Univ, Med Ctr, Dept Human Movement Sci, NL-6200 MD Maastricht, Netherlands
[7] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium
[8] VieCuri Med Ctr, Dept Internal Med, Venlo, Netherlands
关键词
QUANTITATIVE COMPUTED-TOMOGRAPHY; MICROARCHITECTURE; FRACTURES; PRECISION; QUALITY; DENSITY;
D O I
10.2106/JBJS.O.00127
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: High-resolution peripheral quantitative computed tomography (HR-pQCT) is a promising tool to assess the fracture-healing process at the microscale in vivo. Since casts are often used during fracture treatment, they might affect the assessment of bone density, microarchitectural, and biomechanical parameters and the short-term reproducibility of those parameters, e.g., as a result of beam-hardening. The aim of this study was to assess the effect of a plaster-of-Paris and/or fiberglass cast on bone parameters and on the short-term reproducibility of the HR-pQCT measurements of those parameters. Methods: The effects of a cast on HR-pQCT-derived bone parameters were evaluated by comparing HR-pQCT scans of fifteen human cadaveric distal radial specimens from one male and fourteen female donors (median age, eighty-four years [ range, sixty-two to ninety years] at the time of death) in three conditions: with a plaster-of-Paris cast, with a fiberglass cast, or without a cast. Short-term reproducibility was assessed using duplicate scans of the distal end of the radius in sixteen healthy volunteers without a fracture (nine men and seven women with a median age of twenty-six years; range, twenty-two to thirty-nine years) while wearing and not wearing a fiberglass cast. Results: Compared with measurements made with no cast, the plaster-of-Paris cast introduced a systematic error in the bone parameters ranging from -2.6% in trabecular separation to -9.8% in cortical thickness. Bone parameters were affected only marginally by fiberglass, with errors between -0.6% and -1.6% in trabecular separation and cortical thickness, respectively. Short-term reproducibility with a fiberglass cast was similar to that with no cast: approximately 1% for bone density parameters, 4% to 5% for microarchitectural parameters, and 3% to 4% for biomechanical parameters. Conclusions: A plaster-of-Paris cast has a considerable effect on HR-pQCT measurements. A fiberglass cast only marginally affects the bone parameters, and the short-term reproducibility of HR-pQCT measurements in patients with a fiberglass cast is comparable with that in patients without a cast. In studies on fracture-healing using HR-pQCT, a fiberglass cast is desirable if immobilization is indicated. The use of a plaster-of-Paris cast should be avoided if possible; however, if not avoidable, corrections after the scan are desirable to adjust for the error introduced in the bone parameters.
引用
收藏
页码:356 / 362
页数:7
相关论文
共 22 条
  • [1] BONNICK S.L., 2004, BONE DENSITOMETRY CL
  • [2] In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
    Boutroy, S
    Bouxsein, ML
    Munoz, F
    Delmas, PD
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (12) : 6508 - 6515
  • [3] Bone micro-architecture and determinants of strength in the radius and tibia: age-related changes in a population-based study of normal adults measured with high-resolution pQCT
    Dalzell, N.
    Kaptoge, S.
    Morris, N.
    Berthier, A.
    Koller, B.
    Braak, L.
    van Rietbergen, B.
    Reeve, J.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2009, 20 (10) : 1683 - 1694
  • [4] Assessment of the healing process in distal radius fractures by high resolution peripheral quantitative computed tomography
    de Jong, Joost J. A.
    Willems, Paul C.
    Arts, Jacobus J.
    Bours, Sandrine G. P.
    Brink, Peter R. G.
    van Geel, Tineke A. C. M.
    Poeze, Martijn
    Geusens, Piet P.
    van Rietbergen, Bert
    van den Bergh, Joop P. W.
    [J]. BONE, 2014, 64 : 65 - 74
  • [5] Short-term in vivo precision of BMD and parameters of trabecular architecture at the distal forearm and tibia
    Engelke, K.
    Stampa, B.
    Timm, W.
    Dardzinski, B.
    de Papp, A. E.
    Genant, H. K.
    Fuerst, T.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2012, 23 (08) : 2151 - 2158
  • [6] ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES
    GLUER, CC
    BLAKE, G
    LU, Y
    BLUNT, BA
    JERGAS, M
    GENANT, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) : 262 - 270
  • [7] Implications for Fracture Healing of Current and New Osteoporosis Treatments: An ESCEO Consensus Paper
    Goldhahn, J.
    Feron, J. -M.
    Kanis, J.
    Papapoulos, S.
    Reginster, J. -Y.
    Rizzoli, R.
    Dere, W.
    Mitlak, B.
    Tsouderos, Y.
    Boonen, S.
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2012, 90 (05) : 343 - 353
  • [8] Changes of microstructure and mineralized tissue in the middle and late phase of osteoporotic fracture healing in rats
    Hao, Yingjie
    Zhang, Ge
    Wang, Yisheng
    Qin, Ling
    Hung, W. Y.
    Kwoksui, Leung
    Pei, Fuxing
    [J]. BONE, 2007, 41 (04) : 631 - 638
  • [9] Direct three-dimensional morphometric analysis of human cancellous bone:: Microstructural data from spine, femur, iliac crest, and calcaneus
    Hildebrand, T
    Laib, A
    Müller, R
    Dequeker, J
    Rüegsegger, P
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (07) : 1167 - 1174
  • [10] Hubbell J.H., 2009, Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients from 1 kev to 20 mev for elements z = 1 to 92 and 48 additional substances of dosimetric interest