HIGH-ACCURACY PHOTOGRAMMETRIC TECHNIQUE FOR HUMAN SPINE MEASUREMENT

被引:7
作者
Chong, Albert K. [1 ]
Milburn, Peter [2 ]
Newsham-West, Richard [2 ]
ter Voert, Marieke [3 ]
机构
[1] Univ So Queensland, Toowoomba, Qld 4350, Australia
[2] Griffith Univ, Gold Coast, Qld, Australia
[3] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
关键词
anthropometric landmark; field camera calibration; spine measurement; BACK SHAPE; SHRINKAGE; STATURE; MOTION; SYSTEM; RANGE; AGE;
D O I
10.1111/j.1477-9730.2009.00540.x
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
Close range photogrammetry has been recognised as an essential tool for the capture of high-accuracy spatial data for medical applications, in particular work involving dynamic human body parts such as limbs. Offline and online photogrammetric systems are readily available for a number of common applications. However, off-the-shelf systems are not always appropriate because of project site conditions. To achieve high measurement accuracy in a field environment, a modified field camera calibration technique was introduced. The technique is particularly important where each camera is limited to one captured image during calibration, as the camera and the calibration testfield are in fixed positions. In this paper a custom-built imaging system designed for the study of the human spine in an outdoor environment is introduced. The discussion addresses: (1) imaging system design; (2) modified field calibration techniques; and (3) a case study on human spines. Two field camera calibration techniques were evaluated, both of which improved the accuracy of the prototype system, the use of a detachable target board offering the best results. This modified camera calibration procedure has improved the 3D measurement accuracy from 1.25 +/- 0.3mm to 0.43 +/- 0.1 mm. The improvement is at a level achievable in the laboratory. The technique is considered to provide accurate and reliable anthropometric landmark measurement at low cost. This was evaluated in a clinical setting where diurnal changes in spine length and contour were measured in a cohort of 30 university students. The capability of the technique to measure sagittal and frontal angular changes provides a novel way of examining changes in spine shape.
引用
收藏
页码:264 / 279
页数:16
相关论文
共 38 条
[1]   A new system for measuring three-dimensional back shape in scoliosis [J].
Berryman, Fiona ;
Pynsent, Paul ;
Fairbank, Jeremy ;
Disney, Simon .
EUROPEAN SPINE JOURNAL, 2008, 17 (05) :663-672
[2]  
BEYER HA, 1992, 51 ETH I GEOD PHOT
[3]   AN ANALYSIS OF NORMAL BACK SHAPE MEASURED BY ISIS SCANNING [J].
CARR, AJ ;
JEFFERSON, RJ ;
TURNERSMITH, AR ;
BEAVIS, A .
SPINE, 1991, 16 (06) :656-659
[4]   Metric capabilities of low-cost digital cameras for close range surface measurement [J].
Chandler, JH ;
Fryer, JG ;
Jack, A .
PHOTOGRAMMETRIC RECORD, 2005, 20 (109) :12-26
[5]   An approach of dynamically forming an acceptable transcoding path by a search algorithm based on a context-free grammar in a MPEG21 DIA [J].
Chon, SM ;
Lim, YH .
SIGNAL PROCESSING-IMAGE COMMUNICATION, 2006, 21 (02) :113-129
[6]  
Chong A.K., 2008, The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, VXXXVII, P921
[7]  
Chong AK, 2002, PHOTOGRAMM ENG REM S, V68, P745
[8]   The development of camera calibration methods and models [J].
Clarke, TA ;
Fryer, JG .
PHOTOGRAMMETRIC RECORD, 1998, 16 (91) :51-66
[9]  
Cooper M.A.R., 1996, CLOSE RANGE PHOTOGRA, P9
[10]  
DURDLE NG, 1997, SURG TREATMENT SPINA, V1, P407