Long-term follow-up of cataract surgery in eyes filled with silicone oil

被引:2
作者
Kanclerz, Piotr [1 ]
Leisser, Christoph [2 ,3 ]
Grzybowski, Andrzej [4 ,5 ]
Lipowski, Pawel [6 ]
机构
[1] Hygeia Clin, PL-80286 Gdansk, Poland
[2] Karl Landsteiner Inst, VIROS Vienna Inst Res Ocular Surg, A-1140 Vienna, Austria
[3] Hanusch Hosp, A-1140 Vienna, Austria
[4] Univ Warmia & Mazury, Dept Ophthalmol, PL-10082 Olsztyn, Poland
[5] Fdn Ophthalmol Dev, Inst Res Ophthalmol, PL-60554 Poznan, Poland
[6] Med Univ Gdansk, Dept Ophthalmol, PL-80952 Gdansk, Poland
关键词
biometry; cataract surgery; intraocular lens; outcomes; phacoemulsification; refraction; silicone oil; INTRAOCULAR-LENS IMPLANTATION; PARS-PLANA VITRECTOMY; REFRACTIVE OUTCOMES; AXIAL LENGTH; TAMPONADE; BIOMETRY; PHACOEMULSIFICATION; REMOVAL;
D O I
10.18240/ijo.2021.01.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To evaluate the refractive and long-term outcome of eyes filled with silicone oil (SO) undergoing phacoemulsification cataract surgery (PCS). METHODS: This retrospective study evaluated patients with SO tamponade who were scheduled for PCS. RESULTS: Subjects (n=26) were followed for 29.5 +/- 13.9mo after cataract surgery. The median spherical equivalent refraction (SER) was +5.3 D [interquartile range (IQR) +2.9 to +6.7] before PCS, and +3.4 D (IQR +2.0 to +4.4) after PCS. Within the follow-up period retinal reattachment after SO removal was achieved in 15 out of 26 eyes (57.7%). In 13 eyes assessment of refraction after SO-removal was possible, and showed a myopic shift of -4.6 D (IQR -2.9 to -7.3) in the SER. After SO removal, 5 of the 13 eyes (38.5%) were within +/- 1.0 D of the target refraction, while 9 out of the 13 eyes (69.2%) were within +/- 2.0 D. CONCLUSION: In our study, the refraction after PCS for eyes filled with SO manifested low predictability, as did the myopic shift following SO removal. A significant percentage of the eyes that underwent SO administration required a long-term tamponade.
引用
收藏
页码:72 / 75
页数:4
相关论文
共 21 条
  • [1] IMMERSION B-GUIDED VERSUS CONTACT A-MODE BIOMETRY FOR ACCURATE MEASUREMENT OF AXIAL LENGTH AND INTRAOCULAR LENS POWER CALCULATION IN SILICONIZED EYES
    Abu El Einen, Khaled G.
    Shalaby, Mervat H.
    El Shiwy, Hoda T.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (02): : 262 - 265
  • [2] Visual Outcomes and Refractive Status after Combined Silicone Oil Removal/Cataract Surgery with Intraocular Lens Implantation
    Al-Habboubi, Hussain F.
    Al-Zamil, Waseem
    Al-Habboubi, Ali A.
    Khandekar, Rajiv
    [J]. JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (01) : 17 - 22
  • [3] Silicone Oil: Different Physical Proprieties and Clinical Applications
    Barca, Francesco
    Caporossi, Tomaso
    Rizzo, Stanislao
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [4] Combined surgery and sequential surgery comprising phacoemulsification, pars plana vitrectomy, and intraocular lens implantation - Comparison of clinical outcomes
    Chung, TY
    Chung, H
    Lee, JH
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (11) : 2001 - 2005
  • [5] Partial coherence interferometry: A novel approach to biometry in cataract surgery
    Drexler, W
    Findl, O
    Menapace, R
    Rainer, G
    Vass, C
    Hitzenberger, CK
    Fercher, AF
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) : 524 - 534
  • [6] Refractive shift of silicone oil tamponade in pseudophakic eye
    Fang, Wei
    Li, Jiuke
    Jin, Xiaohong
    Zhai, Jing
    Dai, Yuanmin
    Li, Yumin
    [J]. BMC OPHTHALMOLOGY, 2016, 16
  • [8] Visual acuity measurements
    Holladay, JT
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) : 287 - 290
  • [9] Accuracy of Intraocular Lens Power Calculation in Eyes Filled with Silicone Oil
    Kanclerz, Piotr
    Grzybowski, Andrzej
    [J]. SEMINARS IN OPHTHALMOLOGY, 2019, 34 (05) : 392 - 397
  • [10] Complications of cataract surgery in eyes filled with silicone oil
    Kanclerz, Piotr
    Grzybowski, Andrzej
    Schwartz, Stephen G.
    Lipowski, Pawel
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (04) : 465 - 468