CFD analysis on heat transfer characteristics and fluid flow structure in a square duct with modified wavy baffles

被引:19
作者
Boonloi, Amnart [1 ]
Jedsadaratanachai, Withada [2 ]
机构
[1] King Mongkuts Univ Technol North Bangkok, Coll Ind Technol, Dept Mech Engn Technol, Bangkok 10800, Thailand
[2] King Mongkuts Inst Technol Ladkrabang, Sch Engn, Dept Mech Engn, Bangkok 10520, Thailand
关键词
Finite volume method; Numerical study; Square duct; Thermal performance; Wavy baffles; SOLAR AIR HEATER; V-SHAPED RIBS; THERMOHYDRAULIC PERFORMANCE; FRICTION FACTOR; NUSSELT NUMBER; DOWN RIB; ROUGHNESS; GAP;
D O I
10.1016/j.csite.2021.101660
中图分类号
O414.1 [热力学];
学科分类号
摘要
Performance assessments, and flow and heat transfer patterns of a square duct attached with different six types of modified wavy baffles are presented. The influences of fluid blockage ratios or baffle heights (b = 0.05H-0.30H), flow directions (+x and -x) and baffle shapes (A - F) on augmented Nusselt number and fluid flow mechanisms are numerically studied for the laminar flow of the Reynolds number in a range of 100-2000. The simulated problem is solved with the finite volume method (commercial program) using the Semi-Implicit Method for Pressure-Linked Equations (SIMPLE algorithm). The mechanisms (streamlines across the cross-sectional planes, temperature contours, Nusselt number contours) of the tested duct are focused. From the simulated results, the vortex flows are observed to be the main point for the heat transfer increment for all investigated cases. Over the investigated range, the greatest Nusselt number is found to be around 20.10 times higher than that of the plain duct. The maximum TEF of 3.70 is shown at b = 0.10H of the type D modified wavy baffle with the +x flow direction.
引用
收藏
页数:14
相关论文
共 26 条
[1]   Employing V-shaped ribs and nanofluid as two passive methods to improve second law characteristics of flow within a square channel: A two-phase approach [J].
Bahiraei, Mehdi ;
Mazaheri, Nima ;
Moayedi, Hossein .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 151
[2]   A two-phase simulation for analyzing thermohydraulic performance of Cu-water nanofluid within a square channel enhanced with 90° V-shaped ribs [J].
Bahiraei, Mehdi ;
Mazaheri, Nima ;
Hosseini, Yaghoub ;
Moayedi, Hossein .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 145
[3]   Evaluation of turbulent forced convection of non-Newtonian aqueous solution of CMC/CuO nanofluid in a tube with twisted tape inserts [J].
Bazdidi-Tehrani, Farzad ;
Khanmohamadi, Seyed Mehdi ;
Vasefi, Seyed Iman .
ADVANCED POWDER TECHNOLOGY, 2020, 31 (03) :1100-1113
[4]   Influence of perforated triple twisted tape on thermal performance characteristics of a tube heat exchanger [J].
Bhuiya, Muhammad Mostafa Kamal ;
Roshid, Md Mamunur ;
Talukder, Md Mehdi Masud ;
Rasul, Mohammad Golam ;
Das, Prasanjit .
APPLIED THERMAL ENGINEERING, 2020, 167
[5]   Numerical assessments of flow pattern and heat transfer profile for the round tube equipped with different configurations of the dual-inclined baffle [J].
Boonloi, Amnart ;
Jedsadaratanachai, Withada .
CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
[6]   Experimental investigation of impinging jet array heat transfer from a surface with V-shaped and convergent-divergent ribs [J].
Caliskan, S. ;
Baskaya, S. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 59 :234-246
[7]  
Cengel Y.A., 2010, Heat and mass transfer: fundamentals and applications, V4th
[8]   Performance analysis of solar air heater duct roughened with multigap V-down ribs combined with staggered ribs [J].
Deo, Narinderpal Singh ;
Chander, Subhash ;
Saini, J. S. .
RENEWABLE ENERGY, 2016, 91 :484-500
[9]   Overview of V-RIB geometries in solar air heater and performance evaluation of a new V-RIB geometry [J].
Jain, Piyush Kumar ;
Lanjewar, Atul .
RENEWABLE ENERGY, 2019, 133 :77-90
[10]   Thermohydraulic performance of solar air heater with staggered multiple V-shaped ribs on the absorber plate [J].
Jin, Dongxu ;
Zuo, Jianguo ;
Quan, Shenglin ;
Xu, Shiming ;
Gao, Hao .
ENERGY, 2017, 127 :68-77