Transverse slot antennas for high field MRI

被引:24
作者
Alon, Leeor [1 ,2 ,3 ,4 ,5 ]
Lattanzi, Riccardo [1 ,2 ,3 ,4 ]
Lakshmanan, Karthik [1 ,2 ,3 ,4 ]
Brown, Ryan [1 ,2 ,3 ,4 ]
Deniz, Cem M. [1 ,2 ,3 ,4 ,5 ]
Sodickson, Daniel K. [1 ,2 ,3 ,4 ]
Collins, Christopher M. [1 ,2 ,3 ,4 ]
机构
[1] NYU, Sch Med, Ctr Adv Imaging Innovat & Res CAI2R, New York, NY 10016 USA
[2] NYU, Sch Med, Dept Radiol, Bernard & Irene Schwartz Ctr Biomed Imaging, New York, NY 10016 USA
[3] NYU, Sch Med, Sackler Inst Grad Biomed Sci, New York, NY 10016 USA
[4] NYU, Tandon Sch Engn, NYU WIRELESS, Brooklyn, NY USA
[5] RF Test Labs Inc, New York, NY USA
关键词
high field MRI; slot antenna; RF antennas; coil arrays; MAGNETIC-RESONANCE; 7; TESLA; ARRAY; COIL; HOMOGENEITY; DESIGN; POWER; SNR;
D O I
10.1002/mrm.27095
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeIntroduce a novel coil design using an electrically long transversely oriented slot in a conductive sheet. Theory and MethodsTheoretical considerations, numerical simulations, and experimental measurements are presented for transverse slot antennas as compared with electric dipole antennas. ResultsSimulations show improved central and average transmit and receive efficiency, as well as larger coverage in the transverse plane, for a single slot as compared to a single dipole element. Experiments on a body phantom confirm the simulation results for a slot antenna relative to a dipole, demonstrating a large region of relatively high sensitivity and homogeneity. Images in a human subject also show a large imaging volume for a single slot and six slot antenna array. High central transmit efficiency was observed for slot arrays relative to dipole arrays. ConclusionTransverse slots can exhibit improved sensitivity and larger field of view compared with traditional conductive dipoles. Simulations and experiments indicate high potential for slot antennas in high field MRI. Magn Reson Med 80:1233-1242, 2018. (c) 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
引用
收藏
页码:1233 / 1242
页数:10
相关论文
共 29 条
  • [1] Characterization and reduction of gradient-induced eddy currents in the RF shield of a TEM resonator
    Alecci, M
    Jezzard, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 404 - 407
  • [2] Baum C, 1975, ANT PROP SOC INT S U
  • [3] Breast MRI at 7 Tesla with a bilateral coil and robust fat suppression
    Brown, Ryan
    Storey, Pippa
    Geppert, Christian
    McGorty, KellyAnne
    Leite, Ana Paula Klautau
    Babb, James
    Sodickson, Daniel K.
    Wiggins, Graham C.
    Moy, Linda
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (03) : 540 - 549
  • [4] Travelling-wave nuclear magnetic resonance
    Brunner, David O.
    De Zanche, Nicola
    Froehlich, Juerg
    Paska, Jan
    Pruessmann, Klaas P.
    [J]. NATURE, 2009, 457 (7232) : 994 - U2
  • [5] Chen G., 2014, P 22 ANN M ISMRM MIL
  • [6] Design and Application of a Four-Channel Transmit/Receive Surface Coil for Functional Cardiac Imaging at 7T
    Dieringer, Matthias A.
    Renz, Wolfgang
    Lindel, Tomasz
    Seifert, Frank
    Frauenrath, Tobias
    von Knobelsdorff-Brenkenhoff, Florian
    Waiczies, Helmar
    Hoffmann, Werner
    Rieger, Jan
    Pfeiffer, Harald
    Ittermann, Bernd
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (03) : 736 - 741
  • [7] A 7T Spine Array Based on Electric Dipole Transmitters
    Duan, Qi
    Nair, Govind
    Gudino, Natalia
    de Zwart, Jacco A.
    van Gelderen, Peter
    Murphy-Boesch, Joe
    Reich, Daniel S.
    Duyn, Jeff H.
    Merkle, Hellmut
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 1189 - 1197
  • [8] A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI
    Erturk, M. Arcan
    Raaijmakers, Alexander J. E.
    Adriany, Gregor
    Ugurbil, Kamil
    Metzger, Gregory J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 884 - 894
  • [9] Fautz HP, 2008, P INT SOC MAGN RESON, V16, P1247
  • [10] Waist circumference of healthy men and women in the United States
    Flegal, K. M.
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 2007, 31 (07) : 1134 - 1139