A confirmatory method for the determination of tetracyclines in muscle using high-performance liquid chromatography with diode-array detection

被引:45
作者
Cristofani, Elisa [1 ]
Antonini, Chiara [1 ]
Tovo, Gloria [1 ]
Fioroni, Laura [1 ]
Piersanti, Arianna [1 ]
Galarini, Roberta [1 ]
机构
[1] Ist Zooprofilattico Sperimentale Umbria & Marche, I-06126 Perugia, Italy
关键词
Tetracyclines; 4-Epimers; Muscle; High-performance liquid chromatography-diode-array detection; Validation; Commission Decision 2002/657/EC; CHELATE AFFINITY-CHROMATOGRAPHY; ANIMAL-TISSUES; MASS-SPECTROMETRY; RESIDUE ANALYSIS; MILK; CHLORTETRACYCLINE; OXYTETRACYCLINE; ANTIBIOTICS; VALIDATION; HPLC;
D O I
10.1016/j.aca.2008.10.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using high-performance liquid chromatography with diode-array detection (HPLC-DAD) technique, a confirmatory method for the determination of trace levels of tetracyclines (oxytetracycline, tetracycline, chlortetracycline and doxycycline) and their 4-epimers (4-epioxytetracycline, 4-epitetracycline and 4-epichlortetracycline) in animal tissues (muscle) was developed. The samples are extracted with a mixture of succinic acid 0.1 M (pH 4) and methanol after the addition of metacycline as internal standard. The clean-up is carried out by metal chelate affinity chromatography with a following concentration step on an OASIS HLB polymeric reversed phase column. The chromatographic separation of the seven analytes is achieved in 10 min on a short monolithic column (50 mm x 4.6 mm i.d.) using a gradient elution. The method was validated in bovine muscle following the Commission Decision 2002/657/EC criteria: samples spiked at four concentration levels (0.25, 0.5, 1 and 1.5 times the maximum residue limit) were analysed. Method trueness and precision (repeatability and intra-laboratory reproducibility) as well as decision limits (CC alpha) and detection capabilities (CC beta) are reported. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 50 条
  • [41] Determination of Polycyclic Aromatic Hydrocarbons in Commercial Parenteral Formulations and Medications Using High-Performance Liquid Chromatography with Diode Array Detection
    Barichello, Marcia M.
    Bohrer, Denise
    Viana, Carine
    Carvalho, Leandro M.
    Nascimento, Paulo C.
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (04) : 1070 - 1076
  • [42] Determination of metoprolol in human plasma and urine by high-performance liquid chromatography with fluorescence detection
    Yilmaz, Bilal
    Asci, Ali
    Arslan, Sakir
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (13) : 1904 - 1908
  • [43] Determination of tetracyclines residues in milk using high performance liquid chromatography with chemiluminescence detection
    Zhang Yan-Tu
    Zhang Zhu-Jun
    Sun Yong-Hua
    ACTA CHIMICA SINICA, 2006, 64 (24) : 2461 - 2466
  • [44] Determination of low levels of polycyclic aromatic hydrocarbons in soil by high performance liquid chromatography with tandem fluorescence and diode-array detectors
    Huang, Yujuan
    Wei, Jing
    Song, Jing
    Chen, Mengfang
    Luo, Yongming
    CHEMOSPHERE, 2013, 92 (08) : 1010 - 1016
  • [45] ISOLATION AND DETERMINATION OF PASPALITREM-TYPE TREMORGENIC MYCOTOXINS USING LIQUID-CHROMATOGRAPHY WITH DIODE-ARRAY DETECTION
    SELALA, MI
    MUSUKU, A
    SCHEPENS, PJC
    ANALYTICA CHIMICA ACTA, 1991, 244 (01) : 1 - 8
  • [46] Determination of trace tetracyclines in surface water by aluminum hydroxide coprecipitation coupled with high-performance liquid chromatography
    Li, Zhenzhen
    Xu, Kailin
    Liang, Bing
    Li, Yanfang
    ANALYTICAL METHODS, 2013, 5 (14) : 3516 - 3522
  • [47] High-performance liquid chromatography with fluorescence detection for the determination of nitrofuran metabolites in pork muscle
    Sheng, Liang-Quan
    Chen, Ming-Ming
    Chen, Shui-Sheng
    Du, Na-Na
    Liu, Zhao-Di
    Song, Chong-Fu
    Qiao, Rui
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (12): : 2114 - 2122
  • [48] Fluoroquinolone antibiotic determination in bovine milk using capillary liquid chromatography with diode array and mass spectrometry detection
    Ruiz-Viceo, J. A.
    Rosales-Conrado, N.
    Guillen-Casla, V.
    Perez-Arribas, L. V.
    Leon-Gonzalez, M. E.
    Polo-Diez, L. M.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2012, 28 (02) : 99 - 106
  • [49] A novel method using high-performance liquid chromatography with fluorescence detection for the determination of betaxanthins
    Gandía-Herrero, F
    García-Carmona, F
    Escribano, J
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1078 (1-2) : 83 - 89
  • [50] Simultaneous determination of selected ionophoric coccidiostats and amino acids in feed premixes using high-performance liquid chromatography-ultraviolet detection method
    Zayed, Sahar
    Belal, Fathalla
    Barghash, Sona
    Fouad, Fatma
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (04)