A confirmatory method for the determination of tetracyclines in muscle using high-performance liquid chromatography with diode-array detection

被引:45
|
作者
Cristofani, Elisa [1 ]
Antonini, Chiara [1 ]
Tovo, Gloria [1 ]
Fioroni, Laura [1 ]
Piersanti, Arianna [1 ]
Galarini, Roberta [1 ]
机构
[1] Ist Zooprofilattico Sperimentale Umbria & Marche, I-06126 Perugia, Italy
关键词
Tetracyclines; 4-Epimers; Muscle; High-performance liquid chromatography-diode-array detection; Validation; Commission Decision 2002/657/EC; CHELATE AFFINITY-CHROMATOGRAPHY; ANIMAL-TISSUES; MASS-SPECTROMETRY; RESIDUE ANALYSIS; MILK; CHLORTETRACYCLINE; OXYTETRACYCLINE; ANTIBIOTICS; VALIDATION; HPLC;
D O I
10.1016/j.aca.2008.10.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using high-performance liquid chromatography with diode-array detection (HPLC-DAD) technique, a confirmatory method for the determination of trace levels of tetracyclines (oxytetracycline, tetracycline, chlortetracycline and doxycycline) and their 4-epimers (4-epioxytetracycline, 4-epitetracycline and 4-epichlortetracycline) in animal tissues (muscle) was developed. The samples are extracted with a mixture of succinic acid 0.1 M (pH 4) and methanol after the addition of metacycline as internal standard. The clean-up is carried out by metal chelate affinity chromatography with a following concentration step on an OASIS HLB polymeric reversed phase column. The chromatographic separation of the seven analytes is achieved in 10 min on a short monolithic column (50 mm x 4.6 mm i.d.) using a gradient elution. The method was validated in bovine muscle following the Commission Decision 2002/657/EC criteria: samples spiked at four concentration levels (0.25, 0.5, 1 and 1.5 times the maximum residue limit) were analysed. Method trueness and precision (repeatability and intra-laboratory reproducibility) as well as decision limits (CC alpha) and detection capabilities (CC beta) are reported. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 50 条
  • [1] Screening method for the determination of selected tetracyclines in water by liquid chromatography with diode array detector
    Patyra, Ewelina
    Kowalczyk, Ewelina
    Kwiatek, Krzysztof
    BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2014, 58 (01) : 65 - 70
  • [2] TETRACYCLINES AND THEIR EPIMERS IN ANIMAL TISSUES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Gajda, Anna
    Posyniak, Andrzej
    BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2009, 53 (02) : 263 - 267
  • [3] Determination of imidocarb in animal biosamples using simple high-performance liquid chromatography with diode-array detection
    Park, Jin-A.
    Cho, Hee-Jung
    Cho, Soo-Min
    Kim, Na-Hyun
    Kim, Dong-Soon
    Zhang, Dan
    Kim, Seong-Kwan
    Yi, Hee
    Shin, Ho-Chul
    BIOMEDICAL REPORTS, 2014, 2 (01) : 89 - 92
  • [4] Dispersive solid-phase microextraction method for sample extraction in the analysis of four tetracyclines in water and milk samples by high-performance liquid chromatography with diode-array detection
    Tsai, Wen-Hsien
    Huang, Tzou-Chi
    Huang, Joh-Jong
    Hsue, Yi-Huu
    Chuang, Hung-Yi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (12) : 2263 - 2269
  • [5] Determination of enrofloxacin and its metabolite ciprofloxacin in goat milk by high-performance liquid chromatography with diode-array detection - Optimization and validation
    Cinquina, AL
    Roberti, P
    Giannetti, L
    Longo, F
    Draisci, R
    Fagiolo, A
    Brizioli, NR
    JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) : 221 - 226
  • [6] Determination of formaldehyde in spirits by high-performance liquid chromatography with diode-array detection after derivatization
    Burini, G
    Coli, R
    ANALYTICA CHIMICA ACTA, 2004, 511 (01) : 155 - 158
  • [7] High-performance liquid chromatography using pressurized liquid extraction for the determination of seven tetracyclines in egg, fish and shrimp
    Liu, Yu
    Yang, Hailan
    Yang, Sheng
    Hu, Qiwei
    Cheng, Hongbo
    Liu, Huiyu
    Qiu, Yinsheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 917 : 11 - 17
  • [8] Determination of acetamiprid, imidacloprid, and nitenpyram residues in vegetables and fruits by high-performance liquid chromatography with diode-array detection
    Obana, H
    Okihashi, M
    Akutsu, K
    Kitagawa, Y
    Hori, S
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (16) : 4464 - 4467
  • [9] Simultaneous determination of imidacloprid, thiacloprid, and thiamethoxam in soil and water by high-performance liquid chromatography with diode-array detection
    Ying, GG
    Kookana, RS
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2004, 39 (5-6) : 737 - 746
  • [10] DETERMINATION AND COMPARISON OF MAJOR POLYPHENOL OF FOUR RED FRUITS USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) WITH DIODE-ARRAY DETECTION
    Khorsandi, Khatereh
    Hosseinzadeh, Reza
    JOURNAL OF MICROBIOLOGY BIOTECHNOLOGY AND FOOD SCIENCES, 2013, 3 (03): : 250 - 252