Development, validation, and assessment of a high fidelity chilled water plant model

被引:11
作者
Baillie, Brian P. [1 ]
Bollas, George M. [1 ]
机构
[1] Univ Connecticut, Dept Biomol & Chem Engn, 191 Auditorium Rd,Unit 3222, Storrs, CT 06269 USA
关键词
Process simulation; HVAC; Chiller; Model fidelity; OPTIMIZING DESIGN; FAULT-DETECTION; DYNAMIC SIMULATION; BUILDING SYSTEMS; MOVING-BOUNDARY; DIAGNOSTICS; OPTIMIZATION; PROGNOSTICS;
D O I
10.1016/j.applthermaleng.2016.09.125
中图分类号
O414.1 [热力学];
学科分类号
摘要
Effective simulation models of complex systems must achieve an appropriate balance between computational complexity and model fidelity. This work assesses that compromise, in the context of chiller plant modeling, simulation, and optimization. A high-fidelity, equation-based model of a water-cooled chiller is developed and evaluated in comparison to the DOE-2 semi-empirical model, as well as operating data from a real plant. The developed model is found to be realistic in a broader operating range, but computationally expensive for use in real-time optimization, taking approximately 10x computational time compared to the empirical model. The value of this high-fidelity model is demonstrated in simulation case studies that expand beyond the scope of the empirical model and through its suitability as a basis for the development of advanced control architectures. This work identifies the value proposition of the high-fidelity model and illustrates the advantages and disadvantages of each modeling approach, concluding with an outlook of the need for custom, reduced-order models for advanced analysis of chiller plants, targeted to specific uses, such as efficiency optimization and fault detection and accommodation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:477 / 488
页数:12
相关论文
共 43 条
  • [1] Ahn BC, 1999, ELEC SOC S, V98, P1
  • [2] [Anonymous], 2002, INT REFR AIR COND C
  • [3] [Anonymous], 2014, MOD STAND LIB VERS 3
  • [4] Bendapudi S., 2002, TECH REP
  • [5] A comparison of moving-boundary and finite-volume formulations for transients in centrifugal chillers
    Bendapudi, Satyam
    Braun, James E.
    Groll, Eckhard A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (08): : 1437 - 1452
  • [6] Automated fault detection and diagnostics for vapor compression cooling equipment
    Braun, JE
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03): : 266 - 274
  • [7] Braun JE., 1988, Methodologies for the design and control of central cooling plants
  • [8] Chandan V, 2012, P AMER CONTR CONF, P3069
  • [9] Fault diagnosis in HVAC chillers
    Choi, K
    Namburu, SM
    Azam, MS
    Luo, JH
    Pattipati, KR
    Patterson-Hine, A
    [J]. IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2005, 8 (03) : 24 - 32
  • [10] The sensitivity of chiller performance to common faults
    Comstock, MC
    Braun, JE
    Groll, EA
    [J]. HVAC&R RESEARCH, 2001, 7 (03): : 263 - 279