Macrocyclic antibiotics as chiral selectors in the design of enantio selective, potentiometric membrane electrodes for the determination of L- and D-enantiomers of methotrexate

被引:14
作者
Rat'ko, AA
Stefan, RL [1 ]
van Staden, JF
Aboul-Enein, HY
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
[2] King Faisal Specialist Hosp & Res Ctr, Dept Biol & Med Res, Pharmaceut & Drug Dev Lab, Riyadh 11211, Saudi Arabia
关键词
enantioselective; potentiometric membrane electrode; macrocyclic antibiotics; vancomycin; teicoplanin; L(D)-methotrexate;
D O I
10.1016/j.talanta.2004.01.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three enantioselective, potentiometric membrane electrodes (EPMEs) based on macrocyclic glycopeptide antibiotics-vancomycin and teicoplanin (modified or not with acetonitrile)-were proposed for the determination of L- and D-enantiomers of methotrexate (Mtx). The linear concentration ranges for the proposed enantioselective membrane electrodes were between 10(-6) and 10(-3) Mol l(-1) for L- and D- methotrexate. The slopes of the electrodes were 58.00mV/pML-Mtx for vancomycin-based electrode; 57.60mV/PD-MtX for teicoplanin-based electrode and 55.40mV/PD-MtX for teicoplanin modified with acetonitrile-based electrode. The detection limits of the proposed electrodes were of 10(-8) mol l(-1) magnitude order. The surfaces of the electrodes are stable and easily renewable by polishing on alumina paper. All proposed electrodes proved to be successful for the determination of the enantiopurity of Mtx as raw material and of its pharmaceutical formulations (tablets and injections). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 38 条
  • [1] Determination of methotrexate in serum by high-performance liquid chromatography
    Aboleneen, H
    Simpson, J
    Backes, D
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (02): : 317 - 322
  • [2] ACKLAND SP, 1993, J CLIN ONCOL, V11, P2017
  • [3] SIMULTANEOUS QUANTITATION OF METHOTREXATE AND ITS 2 MAIN METABOLITES IN BIOLOGICAL-FLUIDS BY A NOVEL SOLID-PHASE EXTRACTION PROCEDURE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ALBERTIONI, F
    PETTERSSON, B
    BECK, O
    RASK, C
    SEIDEMAN, P
    PETERSON, C
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (01): : 163 - 170
  • [4] ALLEGRA CJ, 1985, J BIOL CHEM, V260, P9720
  • [5] WEEKLY PULSE METHOTREXATE IN RHEUMATOID-ARTHRITIS - CLINICAL AND IMMUNOLOGICAL EFFECTS IN A RANDOMIZED, DOUBLE-BLIND-STUDY
    ANDERSEN, PA
    WEST, SG
    ODELL, JR
    VIA, CS
    CLAYPOOL, RG
    KOTZIN, BL
    [J]. ANNALS OF INTERNAL MEDICINE, 1985, 103 (04) : 489 - 496
  • [6] MACROCYCLIC ANTIBIOTICS AS A NEW CLASS OF CHIRAL SELECTORS FOR LIQUID-CHROMATOGRAPHY
    ARMSTRONG, DW
    TANG, YB
    CHEN, SS
    ZHOU, YW
    BAGWILL, C
    CHEN, JR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (09) : 1473 - 1484
  • [7] COVALENTLY BONDED TEICOPLANIN CHIRAL STATIONARY-PHASE FOR HPLC ENANTIOSEPARATIONS
    ARMSTRONG, DW
    LIU, YB
    EKBORGOTT, KH
    [J]. CHIRALITY, 1995, 7 (06) : 474 - 497
  • [8] USE OF A MACROCYCLIC ANTIBIOTIC AS THE CHIRAL SELECTOR FOR ENANTIOMERIC SEPARATIONS BY TLC
    ARMSTRONG, DW
    ZHOU, YW
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (08): : 1695 - 1707
  • [9] EVALUATION OF THE MACROCYCLIC ANTIBIOTIC VANCOMYCIN AS A CHIRAL SELECTOR FOR CAPILLARY ELECTROPHORESIS
    ARMSTRONG, DW
    RUNDLETT, KL
    CHEN, JR
    [J]. CHIRALITY, 1994, 6 (06) : 496 - 509
  • [10] Facile liquid chromatographic enantioresolution of native amino acids and peptides using a teicoplanin chiral stationary phase
    Berthod, A
    Liu, YB
    Bagwill, C
    Armstrong, DW
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 731 (1-2) : 123 - 137