Assessing MR-linac radiotherapy robustness for anatomical changes in head and neck cancer

被引:22
作者
Chuter, Robert W. [1 ,2 ]
Pollitt, Andrew [1 ]
Whitehurst, Philip [1 ]
MacKay, Ranald I. [1 ,2 ]
van Herk, Marcel [2 ,3 ]
McWilliam, Alan [2 ]
机构
[1] Christie NHS Fdn Trust, CMPE, Wilmslow Rd, Manchester M20 4BX, Lancs, England
[2] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester M13 9PL, Lancs, England
[3] Cent Manchester Univ Hosp NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, NIHR Manchester Biomed Res Ctr, Manchester, Lancs, England
关键词
MR-linac; treatment planning; sinus filling; weight-loss; TRANSVERSE MAGNETIC-FIELD; MODULATED RADIATION-THERAPY; GEOMETRIC CHANGES; DOSE CALCULATION; ACCELERATOR; IMPACT; SCANNER; IMRT; CARCINOMA; VOLUME;
D O I
10.1088/1361-6560/aac749
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The MR-Linac will provide excellent soft tissue contrast for on-treatment imaging. It is well known that the electron return effect (ERE) results in areas of increased and decreased dose at air/tissue boundaries, which can be compensated for in plan optimisation. However, anatomical changes may affect the quality of this compensation. In this paper we aim to quantify the interaction of anatomical changes with ERE in head and neck (H&N) cancer patients. Twenty patients treated with either 66 Gy or 60 Gy in 30 fractions were selected. Ten had significant weight-loss during treatment requiring repeat CT (rCT) and ten had PTVs close to the sinus cavity. Plans were optimised using Monaco to meet the departmental dose constraints and copied to the rCT and re-calculated. For the sinus patients, we optimised plans with full and empty sinus at both 0 T and 1.5 T. The effect of the opposite filling state was next evaluated. No clinically relevant difference between the doses in the PTV and OARs were observed related to weight-loss in 0 T or 1.5 T fields. Variable sinus filling caused greater dosimetric differences near the walls of the sinus for plans optimised with a full cavity in 1.5 T, indicating that optimising with an empty sinus makes the plan more robust to changes in filling. These findings indicate that current off-line strategies for adaptive planning for H&N patients are also valid on an MR-linac, if care is taken with sinus filling.
引用
收藏
页数:12
相关论文
共 25 条
[1]   Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4 [J].
Ahmad, Syed Bilal ;
Sarfehnia, Arman ;
Paudel, Moti Raj ;
Kim, Anthony ;
Hissoiny, Sami ;
Sahgal, Arjun ;
Keller, Brian .
MEDICAL PHYSICS, 2016, 43 (02) :894-907
[2]   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[3]   Factors affecting survival in maxillary sinus cancer [J].
Bhattacharyya, N .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (09) :1016-1021
[4]   WEEKLY VOLUME AND DOSIMETRIC CHANGES DURING CHEMORADIOTHERAPY WITH INTENSITY-MODULATED RADIATION THERAPY FOR HEAD AND NECK CANCER: A PROSPECTIVE OBSERVATIONAL STUDY [J].
Bhide, Shreerang A. ;
Davies, Mark ;
Burke, Kevin ;
McNair, Helen A. ;
Hansen, Vibeke ;
Barbachano, Y. ;
El-Hariry, I. A. ;
Newbold, Kate ;
Harrington, Kevin J. ;
Nutting, Christopher M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05) :1360-1368
[5]   Compensating for the impact of non-stationary spherical air cavities on IMRT dose delivery in transverse magnetic fields [J].
Bol, G. H. ;
Lagendijk, J. J. W. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) :755-768
[6]   Developing an Adaptive Radiotherapy Technique for Virally Mediated Head and Neck Cancer [J].
Brown, Elizabeth ;
Porceddu, Sandro ;
Owen, Rebecca ;
Harden, Fiona .
JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2013, 44 (03) :134-140
[7]   Impact of head and neck cancer adaptive radiotherapy to spare the parotid glands and decrease the risk of xerostomia [J].
Castelli, Joel ;
Simon, Antoine ;
Louvel, Guillaume ;
Henry, Olivier ;
Chajon, Enrique ;
Nassef, Mohamed ;
Haigron, Pascal ;
Cazoulat, Guillaume ;
Ospina, Juan David ;
Jegoux, Franck ;
Benezery, Karen ;
de Crevoisier, Renaud .
RADIATION ONCOLOGY, 2015, 10
[8]  
Gordon AR, 2004, AM J NEURORADIOL, V25, P1092
[9]   Fast dose calculation in magnetic fields with GPUMCD [J].
Hissoiny, S. ;
Raaijmakers, A. J. E. ;
Ozell, B. ;
Despres, P. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) :5119-5129
[10]   Monitoring Dosimetric Impact of Weight Loss With Kilovoltage (KV) Cone Beam CT (CBCT) During Parotid-Sparing IMRT and Concurrent Chemotherapy [J].
Ho, Kean Fatt ;
Marchant, Tom ;
Moore, Chris ;
Webster, Gareth ;
Rowbottom, Carl ;
Penington, Hazel ;
Lee, Lip ;
Yap, Beng ;
Sykes, Andrew ;
Slevin, Nick .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (03) :E375-E382