Characterization of aqueous solution of cresol red as food irradiation dosimeter

被引:8
作者
Khan, H. M. [1 ]
Tabassum, S. [1 ]
Wahid, M. S. [1 ]
机构
[1] Univ Peshawar, Natl Ctr Excellence Phys Chem, Radiat Chem Lab, Peshawar 25120, Pakistan
关键词
COUMARIN DOSIMETER; METHYLENE-BLUE; DYE SOLUTIONS; RADIATION;
D O I
10.1007/s10967-009-7487-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dilute aqueous solution of cresol red has been evaluated spectrophotometrically as possible gamma rays dosimeter. A 0.10 mM solution of cresol red was irradiated by gamma rays using a cobalt-60 radiation source. The absorbance spectra of the unirradiated and irradiated solutions were recorded using double beam scanning spectrophotometer. The absorbance of the solution before and after irradiation was measured at 434 nm (lambda(max)) as well as at other wavelengths (415, 448 and 470 nm). Various parameters, such as Absorbance (A), Delta A, %A, -log A and log A(o)/A(i) were plotted against radiation dose, in order to check the response of cresol red solution and its possible use as chemical dosimeter. The response plots of A, Delta A, and %A versus absorbed dose showed that the solution can be used as a radiation dosimeter in a dose range up to 0.82 kGy. Using response plots of -log A and log A(o)/A(i), the useful dose range can be extended up to 1.65 kGy; which are useful dose ranges for food irradiation applications. Stability studies of cresol red solution at different light and temperature conditions for pre- and post-irradiated storage of the dosimetric solutions suggested that aqueous solution of cresol red is highly stable in dark, under fluorescence light and at room temperature up to 150 days.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 14 条
[1]   Usability of aqueous solutions of methyl red as high-dose dosimeter for gamma radiation [J].
Ajji, Z .
RADIATION MEASUREMENTS, 2006, 41 (04) :438-442
[2]   Formyl violet cyanide liquid dosimetry system [J].
Ebraheem, S. ;
Abdel-Fattah, A. A. ;
Beshir, W. B. ;
Hassan, H. M. ;
Kovacs, A. ;
Wojnarovits, L. .
RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (07) :1218-1221
[3]   ANIONIC TRIPHENYLMETHANE DYE SOLUTIONS FOR LOW-DOSE FOOD IRRADIATION DOSIMETRY [J].
ELASSY, NB ;
YUNDONG, C ;
WALKER, ML ;
ALSHEIKHLY, M ;
MCLAUGHLIN, WL .
RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6) :1189-1197
[4]   HYDROXYANTHRAQUINONE DYE SOLUTIONS FOR RADIATION-DOSIMETRY [J].
ELASSY, NB ;
ALIAN, A ;
RAHIM, FA ;
ROUSHDY, H .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (06) :433-438
[5]   Aqueous solution of basic fuchsin as food irradiation dosimeter [J].
Khan, Hasan M. ;
Naz, Shagufta .
NUCLEAR SCIENCE AND TECHNIQUES, 2007, 18 (03) :141-144
[6]   POSTIRRADIATION STABILITY OF RESPONSE OF AN AQUEOUS COUMARIN DOSIMETER [J].
KHAN, HM ;
ANWAR, M .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1993, 175 (03) :191-198
[7]   Dosimetric characterisation of aqueous solution of brilliant green for low-dose food irradiation dosimetry [J].
Khan, HM ;
Anwer, M ;
Chaudhry, ZS .
RADIATION PHYSICS AND CHEMISTRY, 2002, 63 (3-6) :713-717
[8]   EFFECT OF TEMPERATURE AND LIGHT ON THE RESPONSE OF AN AQUEOUS COUMARIN DOSIMETER [J].
KHAN, HM ;
ANWAR, M ;
AHMAD, G .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1995, 200 (06) :521-527
[9]   Large-scale dosimetry using dilute methylene blue dye in aqueous solution [J].
Kovacs, A ;
Wojnarovits, L ;
Kurucz, C ;
Al-Sheikhly, M ;
McLaughlin, WL .
RADIATION PHYSICS AND CHEMISTRY, 1998, 52 (1-6) :539-542
[10]   Heavy ion radiolysis of methylene blue [J].
LaVerne, JA ;
Tandon, L ;
Knippel, BC ;
Montoya, VN .
RADIATION PHYSICS AND CHEMISTRY, 2005, 72 (2-3) :143-147