Incident analysis of Bucheon LPG filling station pool fire and BLEVE

被引:36
作者
Park, Kyoshik
Mannan, M. Sam [1 ]
Jo, Young-Do
Kim, Ji-Yoon
Keren, Nir
Wang, Yanjun
机构
[1] Texas A&M Univ, Dept Chem Engn, Mary Kay Oconnor Proc Safety Ctr, College Stn, TX 77843 USA
[2] Korea Gas Safety Corp, Inst Gas Safety R&D, Gyeonggi, South Korea
关键词
LPG filling station; cause of incident; LPG unloading; pool fire; BLEVE;
D O I
10.1016/j.jhazmat.2006.01.070
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An LPG filling station incident in Korea has been studied. The direct cause of the incident was concluded to be faulty joining of the couplings of the hoses during the butane unloading process from a tank lorry into an underground storage tank. The faulty connection of a hose to the tank lorry resulted in a massive leak of gas followed by catastrophic explosions. The leaking source was verified by calculating the amount of released LPG and by analyzing captured photos recorded by the television news service. Two BLEVEs were also studied. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 8 条
[1]  
*AM GAS ASS, 1973, LNG INF BOOK
[2]  
CROWL DA, 1990, CHEM PROCESS SAFETY, P121
[3]  
*KOR GAS SAF CORP, 2003, STAT HIGH PRESS GAS, P7
[4]  
*KOR GAS SAF CORP, 2003, ANN REP KOR GAS ACC, P35
[5]  
Lees F, 1996, Loss Prevention in the Process Industry. Hazard Identification, Assessment and Control
[6]  
LEES FP, 1996, LOSS PREVENTION PROC, P16
[7]  
MANNAN MS, 2004, P HAZ 18 I CHEM ENG
[8]  
OConnor M.K., 2003, PROPANE IND INCIDENT