Objectives: Severe right ventricular failure often is considered a contraindication for left ventricular assist device (LVAD) therapy and necessitates use of biventricular assist devices (BiVADs). Available options for BiVADs are limited, and comparative outcomes are largely unknown. Methods: Heart transplant candidates who were registered on the United Network for Organ Sharing waitlist and underwent long-term contemporary LVAD (n = 3195) or BiVAD (n = 408) implantation, from January 2010 through June 2014, were retrospectively analyzed. We evaluated clinical characteristics and outcomes of patients requiring a BiVAD, as well as regional differences in utilization of this technology. Results: Patients requiring a BiVAD were younger (48.9 vs 53.3 years), had a higher proportion of nonischemic disease (69.1% vs 58.2%), a higher bilirubin level (0.9 vs 0.7 mg/dL), and a lower 6-month survival rate (68.1% vs 92.7%) after device implantation (all P<.05). Postimplantation and posttransplantation survival was comparable for commonly used BiVAD configurations, including total artificial heart, continuous flow BiVAD, a continuous-flow LVAD coupled with a right-sided device, and pulsatile flow. Significant variation was found in regional utilization of these devices, regardless of differences in transplantation waitlist times. A large body surface area was an independent predictor of mortality on a BiVAD (hazard ratio = 2.12, P=.017). Conclusions: Outcomes of patients requiring a BiVAD remain poor in the contemporary device era, regardless of the configuration used. Among other clinical factors, body surface area should be incorporated into decision making for device selection in these patients.
引用
收藏
页码:530 / U367
页数:8
相关论文
共 50 条
  • [21] Indications and Outcomes for Temporary Mechanical Circulatory Support in Pediatric Patients with Cardiac Failure
    Bearl, David W.
    Jaquiss, Robert D. B.
    Vesel, Travis P.
    ASAIO JOURNAL, 2019, 65 (04) : 389 - 394
  • [22] BIVENTRICULAR SUPPORT IS SUPERIOR TO UNIVENTRICULAR SUPPORT FOR MECHANICAL CIRCULATORY ASSISTANCE IN PATIENTS AFTER CARDIOTOMY
    YOUNG, JN
    IVERSON, LIG
    ENNIX, CL
    ECKER, RR
    MAY, IA
    JOURNAL OF HEART TRANSPLANTATION, 1987, 6 (05): : 313 - 314
  • [23] Mechanical circulatory support for severe heart failure after operation
    Koyanagi, H
    Kitamura, M
    Aomi, S
    Hachida, M
    Nishida, H
    Endo, M
    ARTIFICIAL ORGANS, 1998, 22 (01) : 82 - 84
  • [24] Mechanical circulatory support bridge for restrictive cardiomyopathy with biventricular and pulmonary failure to cardiac transplantation
    Sainathan, Sandeep
    Mulinari, Leonardo
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, : 578 - 581
  • [25] Contemporary Mechanical Circulatory Support With Continuous-Flow Biventricular Assist Devices: A Systematic Review
    Meece, Lauren E.
    Yu, Julia
    Jeng, Eric, I
    Ahmed, Mustafa M.
    CARDIOLOGY IN REVIEW, 2022, 30 (04) : 197 - 205
  • [26] Factors associated with the need of biventricular mechanical circulatory support in children with advanced heart failure
    Fan, Ye
    Zhang, An-Mei
    Weng, Yu-Guo
    Huebler, Michael
    Miera, Oliver
    Franz, Norbert
    Qian, Gui-Sheng
    Hetzer, Roland
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (05) : 1028 - 1035
  • [27] Cerebrovascular Hemodynamics of Mechanical Circulatory Support Device Patients
    Melmed, Kara R.
    Shlick, Konrad H.
    Rinsky, Brenda
    Song, Shlee S.
    Lyden, Patrick D.
    STROKE, 2017, 48
  • [28] Acute Biventricular Mechanical Circulatory Support for Cardiogenic Shock
    Kuchibhotla, Sudeep
    Esposito, Michele L.
    Breton, Catalina
    Pedicini, Robert
    Mullin, Andrew
    O'Kelly, Ryan
    Anderson, Mark
    Morris, Dennis L.
    Batsides, George
    Ramzy, Danny
    Grise, Mark
    Duc Thinh Pham
    Kapur, Navin K.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (10):
  • [29] LONGITUDINAL AND CONTEMPORARY OUTCOMES OF TEMPORARY MECHANICAL CIRCULATORY SUPPORT IN CARDIAC TRANSPLANTATION
    Clark, Katherine
    Chouiari, Fouad
    Fuery, Michael
    Miller, Paul
    Mullan, Clancy
    Reinhardt, Samuel
    Guha, Avirup
    Desai, Nihar
    Ahmad, Tariq
    Sen, Sounok
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 822 - 822
  • [30] Outcomes of bridge to cardiac retransplantation in the contemporary mechanical circulatory support era
    Sanchez, Joseph E.
    Takayama, Hiroo
    Ando, Masahiko
    Han, Jiho
    Kurlansky, Paul
    Garan, Arthur R.
    Topkara, Veli K.
    Farr, Maryjane
    Colombo, Paolo C.
    Naka, Yoshifumi
    Takeda, Koji
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (01): : 171 - 180