Poly (deep eutectic solvents) as a new class of sustainable sorbents for solid phase extraction: application for preconcentration of Pb (II) from food and water samples

被引:19
作者
Abdolhosseini, Marzieh [1 ]
Shemirani, Farzaneh [1 ]
Yousefi, Seyedeh Mahboobeh [1 ]
机构
[1] Univ Tehran, Univ Coll Sci, Dept Analyt Chem, Fac Chem, POB 14155-6455, Tehran, Iran
关键词
Deep eutectic solvent; Lead determination; Flame atomic absorption spectroscopy; Photopolymerization; Preconcentration; CHOLINE CHLORIDE; PIPETTE-TIP; MICROEXTRACTION; LEAD(II); ADSORBENT; COPPER(II); GRAPHENE; CADMIUM;
D O I
10.1007/s00604-020-04564-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new class of polymeric sorbents based on deep eutectic solvents (DESs) is introduced. These materials are obtained from simple and inexpensive precursors via an energy-efficient process. The primary benefit of these sorbents is that they possess the unique characteristics of DESs and porous materials simultaneously. Moreover, the possibility of tailoring deep eutectic solvents allows designing a specific polymer for a desired analyte, based on its physical and chemical properties. In this work, the deep eutectic solvent of tetrabutylammonium bromide and acrylic acid (1:2 molar ratio) was prepared and then polymerized under solventless condition. The synthesized polymer was characterized by FT-IR spectroscopy, X-ray diffraction (XRD), field emission scanning electron microscopy (SEM), and Brunauer, Emmett and Teller analysis (BET) to evaluate the properties of the sorbent. The poly (TBAB-2AA DES) was applied as a selective sorbent for preconcentration of lead from food and water samples prior to its quantification by flame atomic absorption spectroscopy (FAAS). Variable factors affecting the extraction were optimized, and under the optimum conditions, the calibration plot was linear in the range 5.0-250.0 mu g L-1. The relative standard deviation was (for n=5) (RSD) <3%. The limit of detection (LOD) and the enhancement factor were found to be 2.0 mu g L-1 and 50, respectively. Finally, the accuracy of the method was assessed by comparison of the results with those obtained by direct determination of lead using inductively coupled plasma mass spectrometry (ICP-MS) and spiked real samples. The obtained recoveries were between 92 and 106%.
引用
收藏
页数:9
相关论文
共 35 条
[1]   Deep eutectic solvents formed between choline chloride and carboxylic acids: Versatile alternatives to ionic liquids [J].
Abbott, AP ;
Boothby, D ;
Capper, G ;
Davies, DL ;
Rasheed, RK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (29) :9142-9147
[2]   Lead preconcentration as rac-(E,E)-N,N'-bis(2-chlorobenzylidene)cyclohexane-1,2-diamine complexes from water and tobacco samples by dispersive liquid-liquid microextraction [J].
Alothman, Z. A. ;
Habila, M. A. ;
Yilmaz, E. ;
Warad, I. ;
Soylak, M. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (06) :691-695
[3]   DFT investigation of the reaction mechanism for the guanidine catalysed ring-opening of cyclic carbonates by aromatic and alkyl-amines [J].
Alves, M. ;
Mereau, R. ;
Grignard, B. ;
Detrembleur, C. ;
Jerome, C. ;
Tassaing, T. .
RSC ADVANCES, 2017, 7 (31) :18993-19001
[4]   Application of microwave-assisted dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry for ultra-trace determination of lead and cadmium in cereals and agricultural products [J].
Ataee, Mari ;
Ahmadi-Jouibari, Toraj ;
Fattahi, Nazir .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (03) :271-283
[5]   A magnetic MoS2-Fe3O4 nanocomposite as an effective adsorbent for dispersive solid-phase microextraction of lead(II) and copper(II) prior to their determination by FAAS [J].
Baghban, Neda ;
Yilmaz, Erkan ;
Soylak, Mustafa .
MICROCHIMICA ACTA, 2017, 184 (10) :3969-3976
[6]   Determination of carbamate pesticides using micro-solid-phase extraction combined with high-performance liquid chromatography [J].
Basheer, Chanbasha ;
Alnedhary, Anass Ali ;
Rao, B. S. Madhava ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (02) :211-216
[7]   Magnetic solid-phase extraction for the removal of mercury from water with ternary hydrosulphonyl-based deep eutectic solvent modified magnetic graphene oxide [J].
Chen, Jing ;
Wang, Yuzhi ;
Wei, Xiaoxiao ;
Xu, Panli ;
Xu, Wei ;
Ni, Rui ;
Meng, Jiaojiao .
TALANTA, 2018, 188 :454-462
[8]  
Duruibe JO, 2007, INT J PHYS SCI, V2, P112
[9]   Cyclic electrowinning/precipitation (CEP) system for the removal of heavy metal mixtures from aqueous solutions [J].
Grimshaw, Pengpeng ;
Calo, Joseph M. ;
Hradil, George .
CHEMICAL ENGINEERING JOURNAL, 2011, 175 :103-109
[10]   Activated carbon cloth filled pipette tip for solid phase extraction of nickel(II), lead(II), cadmium(II), copper(II) and cobalt(II) as 1,3,4-thiadiazole-2,5-dithiol chelates for ultra-trace detection by FAAS [J].
Habila, Mohamed A. ;
ALOthman, Zeid A. ;
Yilmaz, Erkan ;
Soylak, Mustafa .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (02) :171-181