Physiology-Based MR Imaging Assessment of CSF Flow at the Foramen Magnum with a Valsalva Maneuver

被引:26
作者
Bhadelia, R. A. [1 ]
Madan, N. [2 ]
Zhao, Y. [4 ]
Wagshul, M. E. [5 ,6 ]
Heilman, C. [3 ]
Butler, J. P. [7 ,8 ]
Patz, S. [9 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02115 USA
[2] Tufts Med Ctr, Dept Radiol, Boston, MA USA
[3] Tufts Med Ctr, Dept Neurosurg, Boston, MA USA
[4] Phillips Med Syst, Boston, MA USA
[5] Albert Einstein Coll Med, Gruss MR Res Ctr, Bronx, NY 10467 USA
[6] Albert Einstein Coll Med, Dept Radiol & Biophys, Bronx, NY 10467 USA
[7] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
[8] Harvard Univ, Sch Med, Dept Med, Boston, MA USA
[9] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
CEREBROSPINAL-FLUID FLOW; CHIARI-I MALFORMATION; WAVE-FORMS; VELOCITY-MEASUREMENTS; PRESSURE RECORDINGS; BLOOD-FLOW; SYRINGOMYELIA; HEADACHE; PATHOPHYSIOLOGY; DISSOCIATION;
D O I
10.3174/ajnr.A3509
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: MR imaging is currently not used to evaluate CSF flow changes due to short-lasting physiological maneuvers. The purpose of this study was to evaluate the ability of MR imaging to assess the CSF flow response to a Valsalva maneuver in healthy participants. MATERIALS AND METHODS: A cardiac-gated fast cine-PC sequence with 15-second acquisition time was used to assess CSF flow in 8 healthy participants at the foramen magnum at rest, during, and immediately after a controlled Valsalva maneuver. CSF mean displacement volume V-CSF during the cardiac cycle and CSF flow waveform A(pp) were determined. A work-in-progress real-time pencil-beam imaging method with temporal resolution 56 ms was used to scan 2 participants for 90 seconds during which resting, Valsalva, and post-Valsalva CSF flow, respiration, and HR were continuously recorded. Results were qualitatively compared with invasive craniospinal differential pressure measurements from the literature. RESULTS: Both methods showed 1) a decrease from baseline in V-CSF and A(pp) during Valsalva and 2) an increase in V-CSF and A(pp) immediately after Valsalva compared with values measured both at rest and during Valsalva. Whereas fast cine-PC produced a single CSF flow waveform that is an average over many cardiac cycles, pencil-beam imaging depicted waveforms for each heartbeat and was able to capture many dynamic features of CSF flow, including transients synchronized with the Valsalva maneuver. CONCLUSIONS: Both fast cine-PC and pencil-beam imaging demonstrated expected changes in CSF flow with Valsalva maneuver in healthy participants. The real-time capability of pencil-beam imaging may be necessary to detect Valsalva-related transient CSF flow obstruction in patients with pathologic conditions such as Chiari I malformation.
引用
收藏
页码:1857 / 1862
页数:6
相关论文
共 27 条
[21]   SIGNIFICANCE OF POSITIVE QUECKENSTEDTS TEST IN PATIENTS WITH SYRINGOMYELIA ASSOCIATED WITH ARNOLD-CHIARI MALFORMATIONS [J].
TACHIBANA, S ;
IIDA, H ;
YADA, K .
JOURNAL OF NEUROSURGERY, 1992, 76 (01) :67-71
[22]   Institutional experience with 500 cases of surgically treated pediatric Chiari malformation Type I Clinical article [J].
Tubbs, R. Shane ;
Beckman, Joshua ;
Naftel, Robert P. ;
Chern, Joshua J. ;
Wellons, John C., III ;
Rozzelle, Curtis J. ;
Blount, Jeffrey P. ;
Oakes, W. Jerry .
JOURNAL OF NEUROSURGERY-PEDIATRICS, 2011, 7 (03) :248-256
[23]  
Wentland AL, 2006, P INT SOC MAG RESON, P1525
[24]   COUGH HEADACHE DUE TO CRANIOSPINAL PRESSURE DISSOCIATION [J].
WILLIAMS, B .
ARCHIVES OF NEUROLOGY, 1980, 37 (04) :226-230
[27]   ON THE PATHOGENESIS OF SYRINGOMYELIA - A REVIEW [J].
WILLIAMS, B .
JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1980, 73 (11) :798-806