Physiology-Based MR Imaging Assessment of CSF Flow at the Foramen Magnum with a Valsalva Maneuver

被引:26
作者
Bhadelia, R. A. [1 ]
Madan, N. [2 ]
Zhao, Y. [4 ]
Wagshul, M. E. [5 ,6 ]
Heilman, C. [3 ]
Butler, J. P. [7 ,8 ]
Patz, S. [9 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02115 USA
[2] Tufts Med Ctr, Dept Radiol, Boston, MA USA
[3] Tufts Med Ctr, Dept Neurosurg, Boston, MA USA
[4] Phillips Med Syst, Boston, MA USA
[5] Albert Einstein Coll Med, Gruss MR Res Ctr, Bronx, NY 10467 USA
[6] Albert Einstein Coll Med, Dept Radiol & Biophys, Bronx, NY 10467 USA
[7] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
[8] Harvard Univ, Sch Med, Dept Med, Boston, MA USA
[9] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
CEREBROSPINAL-FLUID FLOW; CHIARI-I MALFORMATION; WAVE-FORMS; VELOCITY-MEASUREMENTS; PRESSURE RECORDINGS; BLOOD-FLOW; SYRINGOMYELIA; HEADACHE; PATHOPHYSIOLOGY; DISSOCIATION;
D O I
10.3174/ajnr.A3509
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: MR imaging is currently not used to evaluate CSF flow changes due to short-lasting physiological maneuvers. The purpose of this study was to evaluate the ability of MR imaging to assess the CSF flow response to a Valsalva maneuver in healthy participants. MATERIALS AND METHODS: A cardiac-gated fast cine-PC sequence with 15-second acquisition time was used to assess CSF flow in 8 healthy participants at the foramen magnum at rest, during, and immediately after a controlled Valsalva maneuver. CSF mean displacement volume V-CSF during the cardiac cycle and CSF flow waveform A(pp) were determined. A work-in-progress real-time pencil-beam imaging method with temporal resolution 56 ms was used to scan 2 participants for 90 seconds during which resting, Valsalva, and post-Valsalva CSF flow, respiration, and HR were continuously recorded. Results were qualitatively compared with invasive craniospinal differential pressure measurements from the literature. RESULTS: Both methods showed 1) a decrease from baseline in V-CSF and A(pp) during Valsalva and 2) an increase in V-CSF and A(pp) immediately after Valsalva compared with values measured both at rest and during Valsalva. Whereas fast cine-PC produced a single CSF flow waveform that is an average over many cardiac cycles, pencil-beam imaging depicted waveforms for each heartbeat and was able to capture many dynamic features of CSF flow, including transients synchronized with the Valsalva maneuver. CONCLUSIONS: Both fast cine-PC and pencil-beam imaging demonstrated expected changes in CSF flow with Valsalva maneuver in healthy participants. The real-time capability of pencil-beam imaging may be necessary to detect Valsalva-related transient CSF flow obstruction in patients with pathologic conditions such as Chiari I malformation.
引用
收藏
页码:1857 / 1862
页数:6
相关论文
共 27 条
[1]   Magnetic resonance imaging-based measurements of cerebrospinal fluid and blood flow as indicators of intracranial compliance in patients with Chiari malformation [J].
Alperin, N ;
Sivaramakrishnan, A ;
Lichtor, T .
JOURNAL OF NEUROSURGERY, 2005, 103 (01) :46-52
[2]  
Alperin N, 2001, Neurosurg Focus, V11, pE6
[3]  
[Anonymous], 1994, NEUROSURGERY
[4]   QUANTITATIVE CINE-MODE MAGNETIC-RESONANCE-IMAGING OF CHIARI-I MALFORMATIONS - AN ANALYSIS OF CEREBROSPINAL-FLUID DYNAMICS [J].
ARMONDA, RA ;
CITRIN, CM ;
FOLEY, KT ;
ELLENBOGEN, RG .
NEUROSURGERY, 1994, 35 (02) :214-223
[5]   Cough-Associated Headache in Patients with Chiari I Malformation: CSF Flow Analysis by Means of Cine Phase-Contrast MR Imaging [J].
Bhadelia, R. A. ;
Frederick, E. ;
Patz, S. ;
Dubey, P. ;
Erbay, S. H. ;
Do-Dai, D. ;
Heilman, C. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (04) :739-742
[6]  
BHADELIA RA, 1995, AM J NEURORADIOL, V16, P389
[7]   Cerebrospinal fluid flow waveforms: effect of altered cranial venous outflow - A phase-contrast MR flow imaging study [J].
Bhadelia, RA ;
Bogdan, AR ;
Wolpert, SM .
NEURORADIOLOGY, 1998, 40 (05) :283-292
[8]   Cerebrospinal fluid pulsation amplitude and its quantitative relationship to cerebral blood flow pulsations: A phase-contrast MR flow imaging study [J].
Bhadelia, RA ;
Bogdan, AR ;
Kaplan, RF ;
Wolpert, SM .
NEURORADIOLOGY, 1997, 39 (04) :258-264
[9]   CEREBROSPINAL-FLUID FLOW WAVE-FORMS - ANALYSIS IN PATIENTS WITH CHIARI-I MALFORMATION BY MEANS OF GATED PHASE-CONTRAST MR-IMAGING VELOCITY-MEASUREMENTS [J].
BHADELIA, RA ;
BOGDAN, AR ;
WOLPERT, SM ;
LEV, S ;
APPIGNANI, BA ;
HEILMAN, CB .
RADIOLOGY, 1995, 196 (01) :195-202
[10]   NORMAL FLOW PATTERNS OF INTRACRANIAL AND SPINAL CEREBROSPINAL-FLUID DEFINED WITH PHASE-CONTRAST CINE MR IMAGING [J].
ENZMANN, DR ;
PELC, NJ .
RADIOLOGY, 1991, 178 (02) :467-474