The use of laser-induced breakdown spectroscopy for the determination of fluorine concentration in glass ionomer cement

被引:11
作者
Kratochvil, T. [1 ]
Pouzar, M. [1 ]
Novotny, K. [2 ]
Havranek, V. [3 ]
Cernohorsky, T. [1 ]
Zvolska, M. [1 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Pardubice 53210, Czech Republic
[2] Masaryk Univ, Fac Sci, Dept Chem, CS-61137 Brno, Czech Republic
[3] ASCR, Inst Nucl Phys, Vvi, Rez 25068, Czech Republic
关键词
Laser-induced breakdown spectroscopy; Fluorine; Quantitative analysis; GIC; CAPILLARY-ELECTROPHORESIS; ABSORPTION SPECTROMETRY; ION CHROMATOGRAPHY; CHLORINE; AIR; ISOTACHOPHORESIS; TOOTHPASTE; SAMPLES; WATER;
D O I
10.1016/j.sab.2013.08.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The influence of He atmosphere and gate width in laser-induced breakdown spectroscopy (LIBS) determination of fluorine concentration was investigated in detail. The measurements were realized on two double pulse LIBS devices featuring different parameters. Calibration curves, describing the relationship between the fluorine concentration and the corresponding intensity of the LIBS signal, were constructed for both LIBS devices, with and without He flow, respectively. Detection limits achieved were in the range 1.18-0.47 wt.%. The best LOD value was obtained in He atmosphere. The LIBS measurement of fluorine content is influenced by different gate widths and the atmosphere in the working chamber. The proposed method was successfully applied to the determination of fluorine concentration in glass ionomer cements. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 27 条
  • [11] Substances released from dental resin composites and glass ionomer cements
    Geurtsen, W
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (02) : 687 - 695
  • [12] A fast and accurate method for the determination of total and soluble fluorine in toothpaste using high-resolution graphite furnace molecular absorption spectrometry and its comparison with established techniques
    Gleisner, Heike
    Einax, Juergen W.
    Mores, Silvane
    Welz, Bernhard
    Carasek, Eduardo
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (05) : 1040 - 1046
  • [13] Comparison of fluorine determination in biological and environmental samples by NAA, PAA and PIXE
    Havránek, V
    Kucera, J
    Randa, Z
    Vosecek, V
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 259 (02) : 325 - 329
  • [14] Determination of halogens via molecules in the air-acetylene flame using high-resolution continuum source absorption spectrometry: Part I. Fluorine
    Huang, Mao Dong
    Becker-Ross, Helmut
    Florek, Stefan
    Heitmann, Uwe
    Kruss, Michael
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (05) : 572 - 578
  • [15] Use of laser analyser LEA S 500 for analyzing the chemical composition of materials
    Kopachevskii, V. D.
    Krivosheeva, M. A.
    [J]. REFRACTORIES AND INDUSTRIAL CERAMICS, 2007, 48 (04) : 255 - 258
  • [16] Spectroscopic analysis of fire suppressants and refrigerants by laser-induced breakdown spectroscopy
    Lancaster, ED
    McNesby, KL
    Daniel, RG
    Miziolek, AW
    [J]. APPLIED OPTICS, 1999, 38 (09) : 1476 - 1480
  • [17] Chemical state analysis of fluorine in various compounds using X-ray fluorescence spectra
    Nishibu, S
    Yonezawa, S
    Takashima, M
    [J]. JOURNAL OF FLUORINE CHEMISTRY, 2005, 126 (07) : 1048 - 1053
  • [18] Quantitative LIBS analysis of vanadium in samples of hexagonal mesoporous silica catalysts
    Pouzar, Miloslav
    Kratochvil, Tomas
    Capek, Libor
    Smolakova, Lucie
    Cernohorsky, Tomas
    Krejcova, Anna
    Hromadko, Ludek
    [J]. TALANTA, 2011, 83 (05) : 1659 - 1664
  • [19] Sandulescu R, 1996, J PHARMACEUT BIOMED, V14, P951
  • [20] Quantitative analysis of pharmaceutical products by laser-induced breakdown spectroscopy
    St-Onge, L
    Kwong, E
    Sabsabi, M
    Vadas, EB
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (07) : 1131 - 1140