Optimizing patient radiation dose in intervention procedures

被引:18
作者
Chida, Koichi [1 ]
Kato, Mamoru [2 ]
Saito, Haruo
Ishibashi, Tadashi
Takahashi, Shoki [3 ]
Kohzuki, Masahiro [4 ]
Zuguchi, Masayuki
机构
[1] Tohoku Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol,Aoba Ku, Sendai, Miyagi 9808575, Japan
[2] Akita Med Ctr, Dept Radiol, Akita, Japan
[3] Tohoku Univ, Grad Sch Med, Dept Radiol, Sendai, Miyagi 9808575, Japan
[4] Tohoku Univ, Grad Sch Med, Dept Internal Med & Rehabil Sci, Sendai, Miyagi 9808575, Japan
关键词
Angioplasty; catheterization; coronary intervention; interventional; radiation exposure; radiation safety; FLUOROSCOPICALLY GUIDED PROCEDURES; REAL-TIME MEASUREMENT; INDUCED SKIN INJURY; CORONARY-ANGIOGRAPHY; CATHETER ABLATION; AREA PRODUCT; EXPOSURE; DOSIMETER; SAFETY;
D O I
10.3109/02841850903229141
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although numerous patients derive great benefit from interventional procedures, a serious disadvantage associated with interventional procedures is patient radiation dose. Therefore, interventionalists should be aware of how to reduce the radiation dose to their patients. Currently, no conclusive method for reducing radiation dose is available for interventional procedures; hence, it is necessary to combine various methods. In addition, in order to reduce the radiation injury risk in interventional procedures, evaluation of patient radiation dose is essential. Generally, the tradeoff for a decrease in radiation dose is a loss in image performance. Therefore, optimization of radiation dose and image performance is important in interventional procedures.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [31] Radiation Dose in Percutaneous Coronary Intervention OUCH ... Did That Hurt?
    Chambers, Charles E.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) : 344 - 346
  • [32] Interventional spine procedures under CT guidance: How to reduce patient radiation dose without compromising the successful outcome of the procedure?
    Greffier, Joel
    Pereira, Fabricio R.
    Viala, Pierre
    Macri, Francesco
    Beregi, Jean-Paul
    Larbi, Ahmed
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 35 : 88 - 96
  • [33] Radiation Dose Levels for Interventional CT Procedures
    Leng, Shuai
    Christner, Jodie A.
    Carlson, Stephanie K.
    Jacobsen, Megan
    Vrieze, Thomas J.
    Atwell, Thomas D.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (01) : W97 - W103
  • [34] Predictors of Increased Radiation Dose During Percutaneous Coronary Intervention
    Mercuri, Mathew
    Xie, Changchun
    Levy, Michael
    Valettas, Nicholas
    Natarajan, Madhu K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (09) : 1241 - 1244
  • [35] DIRECT DOSE MEASUREMENT ON PATIENT DURING PERCUTANEOUS CORONARY INTERVENTION PROCEDURES USING RADIOPHOTOLUMINESCENCE GLASS DOSIMETERS
    Kato, Mamoru
    Chida, Koichi
    Moritake, Takashi
    Sato, Tadaya
    Oosaka, Hajime
    Toyoshima, Hideto
    Zuguchi, Masayuki
    Abe, Yoshihisa
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (01) : 31 - 37
  • [36] Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention
    Nakamura, Shigeru
    Kobayashi, Tomoko
    Funatsu, Atsushi
    Okada, Tadahisa
    Mauti, Maria
    Waizumi, Yuki
    Yamada, Shinichi
    HEART AND VESSELS, 2016, 31 (05) : 655 - 663
  • [37] Evaluation of the Radiation Dose from the Diagnostic and Topometric Procedures in Radiation Therapy
    Sheina, I. V.
    Obrazkova, M. F.
    Trofymov, A. V.
    Vasilyev, L. L.
    2016 II INTERNATIONAL YOUNG SCIENTISTS FORUM ON APPLIED PHYSICS AND ENGINEERING (YSF), 2016, : 199 - 202
  • [38] Radiation Dose Reduction in the Invasive Cardiovascular Laboratory Implementing a Culture and Philosophy of Radiation Safety
    Fetterly, Kenneth A.
    Mathew, Verghese
    Lennon, Ryan
    Bell, Malcolm R.
    Holmes, David R., Jr.
    Rihal, Charanjit S.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (08) : 867 - 873
  • [39] A preliminary study on the radiation dose reduction during catheterization procedures using simple partial patient shielding
    Serati, Alireza
    Hashemi, Ashkan
    Sharifkashani, Babak
    Nourbakhsh, Sourmah
    Hashemi, Arash
    Emami, Sepideh
    Movahed, Mohammad Reza
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2021, 22 (03) : 891 - 894
  • [40] Radiation Dose Optimization for CT-Guided Interventional Procedures in the Abdomen and Pelvis
    Lamba, Ramit