摘要
The district heating and cooling (DHC) system of a seawater-source heat pump is large system engineering. The investments and the operational cost of DHC pipe network are higher than a tradition system. Traditional design methods only satisfy the needs of the technology but dissatisfy the needs of the economy, which not only waste a mass of money but also bring problems to the operation, the maintenance and the management. So we build a least-annualized-cost global optimal mathematic model that comprises all constrict conditions. Furthermore, this model considers the variety of heating load and cooling load, the operational adjustment in different periods of the year. Genetic algorithm (GA) is used to obtain the optimal combinations of discrete diameters. Some operators of GA are selected to reduce the calculation time and obtain good calculation accuracy. This optimal method is used to the design of the DHC network of Xinghai Bay commercial district which is a real engineering. The design optimization can avoid the matter of the hydraulic unbalance of the system, enhance the running efficiency and greatly reduce the annualized-cost comparing with the traditional design method. Crown Copyright (C) 2009 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:100 / 104
页数:5
相关论文
共 50 条
  • [21] Prospects and challenges of seawater source heat pump utilization in China: A systematic review
    Wang, Luhang
    Xu, Chunwen
    Wang, Chunli
    Zhang, Lancai
    Xu, Huanyong
    Su, Huan
    Zheng, Jianshi
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2025, 210
  • [22] Adjustable performance analysis of combined cooling heating and power system integrated with ground source heat pump
    Wang, Jiangjiang
    Chen, Yuzhu
    Dou, Chao
    Gao, Yuefen
    Zhao, Zheng
    ENERGY, 2018, 163 : 475 - 489
  • [23] Comparison and optimal design of multi-source complementary heating system based on air source heat pump in alpine canyon area of western Sichuan
    Liu Y.
    Zhou W.
    Luo X.
    Hu X.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (10): : 478 - 486
  • [24] Recent advances and development in optimal design and control of ground source heat pump systems
    Ma, Zhenjun
    Xia, Lei
    Gong, Xuemei
    Kokogiannakis, Georgios
    Wang, Shugang
    Zhou, Xinlei
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 131
  • [25] Optimal design of the separate type heat pipe heat exchanger
    俞自涛
    胡亚才
    岑可法
    Journal of Zhejiang University-Science A(Applied Physics & Engineering), 2005, (S1) : 23 - 28
  • [26] Optimal design of the separate type heat pipe heat exchanger
    Yu Z.-T.
    Hu Y.-C.
    Cen K.-F.
    Journal of Zhejiang University-SCIENCE A, 2005, 6 (Suppl 1): : 23 - 28
  • [27] Effect of seawater intake methods on the performance of seawater source heat pump systems in cold climate areas
    Xin, Jia
    Lin, Duanmu
    Shu Haiwen
    ENERGY AND BUILDINGS, 2017, 153 : 317 - 324
  • [28] Simulation Computation and Analysis of Dynamic Operation Energy of Seawater Source Heat Pump
    Wang Jun
    Liu Kai
    Wang Haixia
    Bi Wenfeng
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (9B): : 219 - 221
  • [29] Techno-economic evaluation of a seawater source heat pump system with auxiliary heat source in cold region of China
    Wang, Luhang
    Wang, Chunli
    Xu, Chunwen
    Zhang, Lancai
    Su, Huan
    Kong, Defeng
    ENERGY AND BUILDINGS, 2024, 311
  • [30] Diameter optimization of district heating and cooling piping network based on hourly load
    Zeng, Jing
    Han, Jie
    Zhang, Guoqiang
    APPLIED THERMAL ENGINEERING, 2016, 107 : 750 - 757