Reliability and Validity of Measurements of Knee Extension Strength Obtained from Nursing Home Residents with Dementia

被引:28
作者
Suzuki, Makoto [1 ]
Yamada, Sumio [2 ]
Inamura, Atsushi [3 ]
Omori, Yoshitsugu [4 ]
Kirimoto, Hikari [1 ]
Sugimura, Seiichiro [4 ]
Miyamoto, Masaaki [5 ]
机构
[1] Niigata Univ Hlth & Welf, Fac Med Technol, Niigata 9503198, Japan
[2] Nagoya Univ, Sch Hlth Sci, Nagoya, Aichi 4648601, Japan
[3] Setagaya Municipal Kitazawa En, Dept Hlth Support, Tokyo, Japan
[4] St Marianna Univ, Yokohama City Seibu Hosp, Dept Rehabil Med, Yokohama, Kanagawa, Japan
[5] Fuchinobe Gen Hosp, Dept Rehabil Med, Kanagawa, Japan
关键词
Dementia; Strength Assessment; Gait; Sit-to-stand; Rehabilitation; HAND-HELD DYNAMOMETER; PHYSICAL PERFORMANCE-MEASURES; MINI-MENTAL-STATE; ALZHEIMERS-DISEASE; OLDER-ADULTS; MUSCLE STRENGTH; SUBSTANTIA-NIGRA; STANDING BALANCE; MOTOR UNITS; EXERCISE;
D O I
10.1097/PHM.0b013e3181ae1003
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To describe the reliability of strength measurement by hand-held dynamometer and to identify the prediction of gait and stand-up ability by the strength measurement in people with dementia. Design: Correlational study in which 60 persons with Alzheimer disease were enrolled. The strength of knee extensor was measured twice separated by a 3-min interval using a hand-held dynamometer. The presence or absence of impaired gait and sit-to-stand was also determined. Results: Intraclass correlation coefficient was 0.97. Bland-Altman plots showed the distribution of test-retest differences in the subjects with Mini-Mental State Examination score of 10 points or fewer, increased with isometric knee extensor strength. Logistic regression analysis showed strength of the knee extensor muscles to be a significant predictor of gait performance (odds ratio, 443.0; 95% confidence interval, 9.20-21325.7) and sit-to-stand performance (odds ratio, 47.32; 95% confidence interval, 3.31-675.8). Conclusions: The strength measurement with a hand-held dynamometer was reliable in people with dementia. Furthermore, normalized knee extensor strength was indicated to be a significant predictor of gait and sit-to-stand performance. However, caution is needed when interpreting the result of strength measurement when it is carried out on subjects with a Mini-Mental State Examination score of 10 points or fewer and with a high strength level.
引用
收藏
页码:924 / 933
页数:10
相关论文
共 57 条
[1]  
Aasa U, 2003, J STRENGTH COND RES, V17, P664
[2]  
Akima H, 1997, J Gravit Physiol, V4, pS15
[3]   Normative values for isometric muscle force measurements obtained with hand-held dynamometers [J].
Andrews, AW ;
Thomas, MW ;
Bohannon, RW .
PHYSICAL THERAPY, 1996, 76 (03) :248-259
[4]  
[Anonymous], J AM GERIATR SOC
[5]   Elder rehab: A student-supervised exercise program for Alzheimer's patients [J].
Arkin, SM .
GERONTOLOGIST, 1999, 39 (06) :729-735
[6]   INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY [J].
BARTKO, JJ .
PSYCHOLOGICAL REPORTS, 1966, 19 (01) :3-&
[7]   VALIDITY AND RELIABILITY OF THE DEMENTIA BEHAVIOR DISTURBANCE SCALE [J].
BAUMGARTEN, M ;
BECKER, R ;
GAUTHIER, S .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1990, 38 (03) :221-226
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   STANDING BALANCE, LOWER-EXTREMITY MUSCLE STRENGTH, AND WALKING PERFORMANCE OF PATIENTS REFERRED FOR PHYSICAL THERAPY [J].
BOHANNON, RW .
PERCEPTUAL AND MOTOR SKILLS, 1995, 80 (02) :379-385
[10]   TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1986, 66 (02) :206-209