Electrochemical determination of sulfur-containing amino acid on Screen-Printed Carbon Electrode modified with Graphene Oxide

被引:7
作者
Sasikumar, Ragu [1 ]
Ranganathan, Palraj [2 ]
Chen, Shen-Ming [1 ]
Kavitha, Thavuduraj [3 ]
Lee, Shih-Yi [4 ]
Chen, Tse-Wei [1 ]
Chang, Wen-Han [5 ,6 ,7 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, 1 Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[2] Natl Taipei Univ Technol, Inst Organ & Polymer Mat, 1 Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[3] Sri S Ramasamy Naidu Mem Coll, Dept Chem, Sattur, Tamil Nadu, India
[4] MacKay Mem Hosp, MacKay Med Nursing & Management Coll, Div Pulm & Crit Care Med, Taipei, Taiwan
[5] MacKay Mem Hosp, MacKay Mem Coll, Dept Cardiol, Taipei, Taiwan
[6] Natl Taipei Univ Technol, MacKay Mem Hosp, Inst Mechatron Engn, Dept Emergency Med, Taipei, Taiwan
[7] Taipei Med Univ, Grad Inst Injury Prevent & Control, Dept Med, Taipei, Taiwan
关键词
Graphene oxide; L-Met; lecithin; screen-printed carbon electrode; differential pulse voltammetry; ELECTROPOLYMERIZED FILM; METHIONINE; OXIDATION; INTERCALATION; CYSTEINE; METAL;
D O I
10.20964/2017.05.05
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The current study discussed with sensitive L-Methionine (L-Met) sensor relative on a graphene oxide (GO) modified screen. printed carbon electrode (SPCE) was developed. The fabricated GO/SPCE displayed an enhanced current (I-pa) response towards L-Met relative to that of a bare SPCE. Under optimum conditions, the GO/SPCE showed a wide linear range at L-Met concentrations of 2-96 mu M. The lower level of detection of 0.18 mu M, and sensitivity of about 6.75 mA mM(-1)cm(-2). The fabricated sensor displays good stability, reproducibility, and repeatability.
引用
收藏
页码:4077 / 4085
页数:9
相关论文
共 33 条
[31]   Solvothermal synthesis and characterization of sandwich-like graphene/ZnO nanocomposites [J].
Wu, Jili ;
Shen, Xiaoping ;
Jiang, Lei ;
Wang, Kun ;
Chen, Kangmin .
APPLIED SURFACE SCIENCE, 2010, 256 (09) :2826-2830
[32]   Simultaneous determination of total homocysteine, cysteine and methionine in hypothyroid patients' plasma by liquid chromatography using platinum/poly(methyl violet) modified electrode [J].
Xu, HH ;
Zhang, W ;
Zhu, W ;
Wang, D ;
Ye, J ;
Yamamoto, K ;
Jin, LT .
ANALYTICA CHIMICA ACTA, 2005, 545 (02) :182-188
[33]   A reduced graphene oxide/α-cyclodextrin hybrid for the detection of methionine: electrochemical, fluorometric and computational studies [J].
Zor, Erhan ;
Saglam, Muhammed Esad ;
Alpaydin, Sabri ;
Bingol, Haluk .
ANALYTICAL METHODS, 2014, 6 (16) :6522-6530