Electrochemical determination of sulfur-containing amino acid on Screen-Printed Carbon Electrode modified with Graphene Oxide

被引:7
作者
Sasikumar, Ragu [1 ]
Ranganathan, Palraj [2 ]
Chen, Shen-Ming [1 ]
Kavitha, Thavuduraj [3 ]
Lee, Shih-Yi [4 ]
Chen, Tse-Wei [1 ]
Chang, Wen-Han [5 ,6 ,7 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, 1 Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[2] Natl Taipei Univ Technol, Inst Organ & Polymer Mat, 1 Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[3] Sri S Ramasamy Naidu Mem Coll, Dept Chem, Sattur, Tamil Nadu, India
[4] MacKay Mem Hosp, MacKay Med Nursing & Management Coll, Div Pulm & Crit Care Med, Taipei, Taiwan
[5] MacKay Mem Hosp, MacKay Mem Coll, Dept Cardiol, Taipei, Taiwan
[6] Natl Taipei Univ Technol, MacKay Mem Hosp, Inst Mechatron Engn, Dept Emergency Med, Taipei, Taiwan
[7] Taipei Med Univ, Grad Inst Injury Prevent & Control, Dept Med, Taipei, Taiwan
关键词
Graphene oxide; L-Met; lecithin; screen-printed carbon electrode; differential pulse voltammetry; ELECTROPOLYMERIZED FILM; METHIONINE; OXIDATION; INTERCALATION; CYSTEINE; METAL;
D O I
10.20964/2017.05.05
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The current study discussed with sensitive L-Methionine (L-Met) sensor relative on a graphene oxide (GO) modified screen. printed carbon electrode (SPCE) was developed. The fabricated GO/SPCE displayed an enhanced current (I-pa) response towards L-Met relative to that of a bare SPCE. Under optimum conditions, the GO/SPCE showed a wide linear range at L-Met concentrations of 2-96 mu M. The lower level of detection of 0.18 mu M, and sensitivity of about 6.75 mA mM(-1)cm(-2). The fabricated sensor displays good stability, reproducibility, and repeatability.
引用
收藏
页码:4077 / 4085
页数:9
相关论文
共 33 条
[1]  
[Anonymous], BIOCHEMISTRY
[2]   Intercalation of solid polymer electrolytes into graphite oxide [J].
Bissessur, Rabin ;
Scully, Stephen F. .
SOLID STATE IONICS, 2007, 178 (11-12) :877-882
[3]   Graphene-based materials in electrochemistry [J].
Chen, Da ;
Tang, Longhua ;
Li, Jinghong .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (08) :3157-3180
[4]  
DANIEL O, 1954, Br J Urol, V26, P153, DOI 10.1111/j.1464-410X.1954.tb06078.x
[5]  
Dean John., 1973, LANGES HDB CHEM, V11th
[6]   Boron doped diamond and glassy carbon electrodes comparative study of the oxidation behaviour of cysteine and methionine [J].
Enache, T. A. ;
Oliveira-Brett, A. M. .
BIOELECTROCHEMISTRY, 2011, 81 (01) :46-52
[7]   Graphene nanosheet: synthesis, molecular engineering, thin film, hybrids, and energy and analytical applications [J].
Guo, Shaojun ;
Dong, Shaojun .
CHEMICAL SOCIETY REVIEWS, 2011, 40 (05) :2644-2672
[8]   An Electrochemically Reduced Graphene Oxide-Based Electrochemical Immunosensing Platform for Ultrasensitive Antigen Detection [J].
Haque, Al-Monsur Jiaul ;
Park, Hyejin ;
Sung, Daekyung ;
Jon, Sangyong ;
Choi, Sung-Yool ;
Kim, Kyuwon .
ANALYTICAL CHEMISTRY, 2012, 84 (04) :1871-1878
[9]   Regulation of cell function by methionine oxidation and reduction [J].
Hoshi, T ;
Heinemann, SH .
JOURNAL OF PHYSIOLOGY-LONDON, 2001, 531 (01) :1-11
[10]   Electrochemical determination of L-methionine using the electropolymerized film of non-peripheral amine substituted Cu(II) phthalocyanine on glassy carbon electrode [J].
Jeevagan, A. John ;
John, S. Abraham .
BIOELECTROCHEMISTRY, 2012, 85 :50-55