Metallurgical investigation on fatigue failure of stainless steel chain in a continuous casting machine

被引:6
作者
Pantazopoulos, G. [1 ]
Vazdirvanidis, A. [1 ]
机构
[1] ELKEME Hellen Res Ctr Met SA, Athens 17778, Greece
关键词
High temperature fatigue; Bending fatigue; Stainless steel; Ductile overload;
D O I
10.1016/j.engfailanal.2008.10.021
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Stainless steels strips (chains) are used for the connection of dam blocks in belt casting machines. Thermal cycling and repetitive stressing under complex loading conditions due to tension and bending are the most frequent function modes during production. Samples from fractured stainless steel strips used for the connection of dam blocks in a copper rod continuous casting line, were sent for failure investigation. Optical and scanning electron microscopy for structural and fractographic evaluation along with mechanical testing are used as the principal analytical techniques in the context of the present investigation. Failure analysis findings suggest strongly that the failure was caused by bending fatigue which assisted also by thermal cycling, initiated from the strip surface and followed by ductile final overload fracture. Final fracture occurred via ductile failure, when the remaining strip cross sectional area reaches a critical size, becoming unable to sustain the operating load. Review of the service history (operating conditions, e.g. process design, applied loads, thermal cycles), in combination to the examination of a potential substitution of the material to a more heat (and fatigue) resistant one are suggested as further fatigue damage preventive actions. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1623 / 1630
页数:8
相关论文
共 7 条
[1]  
*ASM INT, 1973, ASM HDB, V7
[2]  
*EUR COMM STAND CE, 2001, 100021 EN EUR COMM S
[3]  
*ISO, 2005, 65071 BS EN ISO
[4]   Creep failures of overheated boiler, superheater and reformer tubes [J].
Jones, DRH .
ENGINEERING FAILURE ANALYSIS, 2004, 11 (06) :873-893
[5]  
JONES DRH, 1993, ENG MAT, V3
[6]   Overheat induced failure of a steel tube in an electric arc furnace (EAF) cooling system [J].
Vazdrvanidis, A. ;
Pantazopoulos, G. ;
Louvaris, A. .
ENGINEERING FAILURE ANALYSIS, 2008, 15 (07) :931-937
[7]  
Wulpi D.J., 2000, Understanding How Components Fail, VSecond