Cerebral Hemodynamics and Brain Functional Activity During Lower Body Negative Pressure

被引:7
作者
Han, Wen-Qiang [1 ]
Hu, Wen-Dong [1 ]
Dong, Ming-Qing [1 ]
Fu, Zhao-Jun [1 ]
Wen, Zhi-Hong [1 ]
Cheng, Hong-Wei [1 ]
Ma, Jin [1 ]
Ma, Rui-Shan [1 ]
机构
[1] Fourth Mil Med Univ, Dept Aerosp Med Equipment, Xian 710032, Peoples R China
来源
AVIATION SPACE AND ENVIRONMENTAL MEDICINE | 2009年 / 80卷 / 08期
关键词
LBNP; cerebral blood flow; brain function; event related potentials; P300; reaction time; tracking error; BLOOD-FLOW VELOCITY; ORTHOSTATIC STRESS; TRANSCRANIAL DOPPLER; ACCELERATION; RESPONSES; AUTOREGULATION; CONSCIOUSNESS; HUMANS;
D O I
10.3357/ASEM.2267.2009
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
HAN W-Q, Hu W-D, DONG M-Q, Fu Z-J, WEN Z-H, CHENG H-W, MA J, MA R-S. Cerebral hemodynamics and brain functional activity during lower body negative pressure. Aviat Space Environ Med 2009; 80:698-702. Introduction: Exposure to high +G(z) acceleration forces on a centrifuge or in an aircraft can severely decrease cerebral blood perfusion and cause rapid G-induced loss of consciousness. However, milder acceleration may gradually reduce cerebral blood flow and affect cognitive function in subtler ways. This study used lower body negative pressure (LBNP) to mimic +G(z) circulatory effects in order to study cerebral hemodynamics and brain function. Methods: Subjects were 15 healthy men, 19-21 yr of age. They were exposed to LBNP at two levels for 5 min each separated by a 10-min recovery period. The conditions were low (LO), -4.00 kPa (-30 mmHg) and high (HI), -6.67 kPa (-50 mmHg). Variables measured before, during, and after LBNP included cerebral blood flow velocity (CBFV) in the middle cerebral artery, blood oxygen saturation (SaO2), heart rate (HR), blood pressure, P300 of event-related EEG potentials, reaction time, and tracking error. Results: LO significantly reduced CBFV at 4 and 5 min, increased HR and decreased the amplitude of P300, but none of the other variables changed from baseline. In contrast, HI produced significant changes in most variables: CBFV decreased at 2 min and then fell further at 4 and 5 min, HR increased, and SaO2 decreased. Significant neurocognitive changes included increased latency and reduced amplitude of P300, slower reaction time, and greater tracking error. Conclusion: The higher level of LBNP used here reduced cerebral perfusion sufficiently to impair neurocognitive function. This model may he useful for further studies of these and other variables under closely controlled conditions.
引用
收藏
页码:698 / 702
页数:5
相关论文
共 23 条
  • [1] Balldin UI, 1996, AVIAT SPACE ENVIR MD, V67, P19
  • [2] Assessment of cerebrovascular and cardiovascular responses to lower body negative pressure as a test of cerebral autoregulation
    Brown, CM
    Dütsch, M
    Hecht, MJ
    Neundörfer, B
    Hilz, MJ
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 2003, 208 (1-2) : 71 - 78
  • [3] Cheng H W, 1999, Space Med Med Eng (Beijing), V12, P23
  • [4] Convertino V A, 2001, J Gravit Physiol, V8, P1
  • [5] Identification of pollination-induced genes from the ovary of apple (Malus domestica)
    Dong, YH
    Kvarnheden, A
    Yao, JL
    Sutherland, PW
    Atkinson, RG
    Morris, BA
    Gardner, RC
    [J]. SEXUAL PLANT REPRODUCTION, 1998, 11 (05): : 277 - 283
  • [6] A new method for fixation of probes for transcranial Doppler ultrasound
    Giller, CA
    Giller, AM
    [J]. JOURNAL OF NEUROIMAGING, 1997, 7 (02) : 103 - 105
  • [7] GLAISTER DH, 1990, AVIAT SPACE ENVIR MD, V61, P99
  • [8] Cerebral autoregulation is preserved during orthostatic stress superimposed with systemic hypotension
    Guo, Hong
    Tierney, Nancy
    Schaller, Frederic
    Raven, Peter B.
    Smith, Scott A.
    Shi, Xiangrong
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (06) : 1785 - 1792
  • [9] Influence of task difficulty on the features of event-related potential during visual oddball task
    Kim, Kyung Hwan
    Kim, Ja Hyun
    Yoon, Jin
    Jung, Ki-Young
    [J]. NEUROSCIENCE LETTERS, 2008, 445 (02) : 179 - 183
  • [10] Kuriyama K, 2000, AVIAT SPACE ENVIR MD, V71, P1033