Gender differences in the accuracy of dobutamine stress echocardiography for the diagnosis of coronary artery disease

被引:45
作者
Elhendy, A [1 ]
Geleijnse, ML [1 ]
vanDomburg, RT [1 ]
Nierop, PR [1 ]
Poldermans, D [1 ]
Bax, JJ [1 ]
TenCate, FJ [1 ]
Nosir, YFM [1 ]
Ibrahim, MM [1 ]
Roelandt, JRTC [1 ]
机构
[1] ERASMUS UNIV ROTTERDAM, UNIV HOSP DIJKZIGT, THORAXCTR, NL-3015 GD ROTTERDAM, NETHERLANDS
关键词
D O I
10.1016/S0002-9149(97)00707-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The accuracy of dobutamine stress echocardiography (DSE) for the diagnosis of coronary artery disease (CAD) has not been yet evaluated in women. We studied the effect of gender on the accuracy of DSE for the diagnosis of CAD in 306 consecutive patients (210 men and 96 women) with limited exercise capacity and suspected myocardial ischemia who underwent coronary angiography within 3 months of DSE. There were no serious complications during DSE. Men had a higher prevalence of nonsustained ventricular tachycardia (7% vs 0.03%, p <0.05) and supraventricular tachycardia (9% vs 0.03%, p <0.05) during the test compared with women. Peak stress rate-pressure product was not different in men and women (18,140 +/- 4,187 vs 18,543 +/- 4,223), Significant CAD (greater than or equal to 50% luminal diameter stenosis) was present in 171 men (81%) and in 62 women (65%, <0.005). The sensitivity, specificity, and accuracy of ischemic pattern at DSE for the diagnosis of significant CAD were 76% (confidence interval [CI] 67 to 84), 94% (CI 89 to 99), and 82% (CI 75 to 90) in women and 73% (CI 67 to 79), 77% (CI 71 to 83), and 74% (CI 68 to 80) in men, respectively. Overall specificity was higher in women than in men (p <0.05), Regional accuracy of DSE was significantly higher in women than in men in the 3 arterial regions (84% [CI 79 to 88] vs 75% [CI 72 to 79], p <0.005). It is concluded that DSE is a safe and Feasible method for the diagnosis of CAD in women. The overall specificity and the regional accuracy of DSE are higher in women than in men. Further studies are required to evaluate the functional significance of these findings and their reproducibility in different patient populations. (C) 1997 by Excerpta Medica, Inc.
引用
收藏
页码:1414 / 1418
页数:5
相关论文
共 23 条
  • [1] FALSE-POSITIVE DOBUTAMINE STRESS ECHOCARDIOGRAMS - CHARACTERIZATION OF CLINICAL, ECHOCARDIOGRAPHIC AND ANGIOGRAPHIC FINDINGS
    BACH, DS
    MULLER, DWM
    GROS, BJ
    ARMSTRONG, WF
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) : 928 - 933
  • [2] QUANTITATIVE CORONARY ANGIOGRAPHY IN THE ESTIMATION OF THE FUNCTIONAL-SIGNIFICANCE OF CORONARY STENOSIS - CORRELATIONS WITH DOBUTAMINE-ATROPINE STRESS TEST
    BAPTISTA, J
    ARNESE, M
    ROELANDT, JRTC
    FIORETTI, P
    KEANE, D
    ESCANED, J
    BOERSMA, E
    DIMARIO, C
    SERRUYS, PW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (06) : 1434 - 1439
  • [3] REPRODUCIBILITY OF THE DOBUTAMINE-ATROPINE ECHOCARDIOGRAPHY STRESS TEST
    BELLOTTI, P
    FIORETTI, PM
    FORSTER, T
    MCNEILL, AJ
    ELSAID, ESM
    SALUSTRI, A
    ROELANDT, JRTC
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1993, 10 (01): : 93 - 97
  • [4] Cardiovascular effects of dobutamine stress testing in women with suspected coronary artery disease
    Blomstrand, P
    Engvall, J
    Swahn, E
    Safstrom, K
    Thulesius, O
    Wranne, B
    [J]. HEART, 1996, 75 (05) : 463 - 468
  • [5] CERQUEIRA MD, 1995, AM J CARDIOL, V75, pD52
  • [6] Crouse L J, 1996, Am J Card Imaging, V10, P65
  • [7] ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE
    DIAMOND, GA
    FORRESTER, JS
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) : 1350 - 1358
  • [8] EVALUATION BY QUANTITATIVE 99M-TECHNETIUM MIBI SPECT AND ECHOCARDIOGRAPHY OF MYOCARDIAL PERFUSION AND WALL-MOTION ABNORMALITIES IN PATIENTS WITH DOBUTAMINE-INDUCED ST-SEGMENT ELEVATION
    ELHENDY, A
    GELEIJNSE, ML
    ROELANDT, JRTC
    VANDOMBURG, RT
    CORNELL, JH
    TENCATE, FJ
    POSTMATJOA, J
    REIJS, AEM
    ELSAID, GM
    FIORETTI, PM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (07) : 441 - 448
  • [9] Relation between contractile response of akinetic segments during dobutamine stress echocardiography and myocardial ischemia assessed by simultaneous thallium-2O1 single-photon emission computed tomography
    Elhendy, A
    Cornel, JH
    Roelandt, JRTC
    vanDomburg, RT
    Nierop, PR
    Geleynse, ML
    ElSaid, GM
    Fioretti, PM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (11) : 955 - 959
  • [10] Accuracy of dobutamine stress echocardiography for the diagnosis of coronary artery stenosis in patients with myocardial infarction: The impact of extent and severity of left ventricular dysfunction
    Elhendy, A
    vanDomburg, RT
    Roelandt, JRTC
    Geleijnse, ML
    Cornel, JH
    ElSaid, GM
    Fioretti, PM
    [J]. HEART, 1996, 76 (02) : 123 - 128