In vivo color flow mapping using synthetic aperture dual stage beamforming

被引:0
作者
Li, Ye [1 ]
Hansen, Peter Moller [1 ]
Hemmsen, Martin Christian [1 ]
Nielsen, Michael Bachmann
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
来源
2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2012年
关键词
ULTRASOUND; FILTERS; MOTION;
D O I
10.1109/ULTSYM.2012.0398
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An in vivo investigation of synthetic aperture flow imaging using a dual stage beamformer is presented in this paper. In the previous work, simulations and Doppler flow phantom experiments showed promising results, which indicated the methods capability of producing fast color flow mapping with a good quality. Due to the continuous data, both high velocity and low velocity can be estimated. Moreover, synthetic aperture flow imaging can be implemented on a commercial platform, because the number of calculations have been reduced. In this work, A commercial ultrasound scanner (Pro Focus equipped with a UA 2227 Research Interface, BK Medical, Herlev, Denmark) was used to transmit signals and record echoes. The data are processed off-line. The method is validated using a pulsatile flow phantom. Volume flow is calculated, and is compared with the volume flow set for the pump. The relative standard deviation is 14:3% and relative bias is 6:4% for the phantom measurements. The blood flow in a common carotid artery of a 35 -year-old healthy male is scanned by a medical doctor (PMH). The in vivo data is processed off-line. Fast synthetic aperture color flow mapping with frame rate of 85 Hz is produced and the volume flow is calculated.
引用
收藏
页码:1592 / 1595
页数:4
相关论文
共 12 条
[1]  
[Anonymous], 2008, INF MAN SEEK MARK CL
[2]   Clutter filter design for ultrasound color flow imaging [J].
Bjærum, S ;
Torp, H ;
Kirstoffersen, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (02) :204-216
[3]   Statistical evaluation of clutter filters in color flow imaging [J].
Bjærum, S ;
Torp, H .
ULTRASONICS, 2000, 38 (1-8) :376-380
[4]  
Hazard CR, 1999, ULTRASON, P1221, DOI 10.1109/ULTSYM.1999.849217
[5]   Implementation of a Versatile Research Data Acquisition System Using a Commercially Available Medical Ultrasound Scanner [J].
Hemmsen, Martin Christian ;
Nikolov, Svetoslav Ivanov ;
Pedersen, Mads Moller ;
Pihl, Michael Johannes ;
Enevoldsen, Marie Sand ;
Hansen, Jens Munk ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) :1487-1499
[6]   IN VIVO EVALUATION OF SYNTHETIC APERTURE SEQUENTIAL BEAMFORMING [J].
Hemmsen, Martin Christian ;
Hansen, Peter Moller ;
Lange, Theis ;
Hansen, Jens Munk ;
Hansen, Kristoffer Lindskov ;
Nielsen, Michael Bachmann ;
Jensen, Jorgen Arendt .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (04) :708-716
[7]   Synthetic Aperture Sequential Beamforming [J].
Kortbek, Jacob ;
Jensen, Jorgen Arendt ;
Gammelmark, Kim Lokke .
2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, :966-+
[8]  
Li Y, 2010, P IEEE ULTRASON S, P1924
[9]  
Li Y, 2011, IFMBE PROC, V34, P53
[10]   Validation of a new blood-mimicking fluid for use in Doppler flow test objects [J].
Ramnarine, KV ;
Nassiri, DK ;
Hoskins, PR ;
Lubbers, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03) :451-459