Improving the performance of hysteresis direct torque control of IPMSM using active filter topology

被引:7
作者
Gulez, Kayhan [1 ]
Adam, Ali Ahmed [1 ]
Pastaci, Halit [1 ]
机构
[1] Yildiz Tech Univ, Elect Elect Fac, Dept Elect Engn, TR-34349 Istanbul, Turkey
来源
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES | 2006年 / 31卷 / 3期
关键词
interior permanent magnet synchronous motor; direct torque control; stator flux linkage; active power filter; voltage harmonics; torque ripples;
D O I
10.1007/BF02703380
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes an active filter topology to improve the performance of hysteresis direct torque control (HDTC) of interior permanent magnet synchronous motor (IPMSM). The filter topology consists of an active filter and two RLC filters, and is connected to the main power circuit through a 1: 1 transformer. The active filter is characterized by detecting the harmonics in the motor phase voltages and injecting equivalent harmonic voltages to produce almost sinusoidal voltage waveform to the motor terminals. The active filter uses hysteresis voltage controller while the motor main circuit uses hysteresis direct torque control. The simulation results of this combined control structure show considerable torque ripple reduction in the steady state range and adequate dynamic torque performance as well as considerable harmonic voltage and EMI noise reduction.
引用
收藏
页码:245 / 258
页数:14
相关论文
共 14 条