Fluorescence-based temperature control for polymerase chain reaction

被引:3
作者
Sanford, Lindsay N. [1 ]
Wittwer, Carl T. [2 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84112 USA
关键词
Polymerase chain reaction (PCR); Fluorescence; Temperature monitoring; High-resolution melting; LASER-INDUCED FLUORESCENCE; REAL-TIME PCR; VELOCITY-MEASUREMENTS; MELTING ANALYSIS; VELOCIMETRY; RESOLUTION; SYSTEM;
D O I
10.1016/j.ab.2013.11.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The ability to accurately monitor solution temperature is important for the polymerase chain reaction (PCR). Robust amplification during PCR is contingent on the solution reaching denaturation and annealing temperatures. By correlating temperature to the fluorescence of a passive dye, noninvasive monitoring of solution temperatures is possible. The temperature sensitivity of 22 fluorescent dyes was assessed. Emission spectra were monitored and the change in fluorescence between 45 and 95 degrees C was quantified. Seven dyes decreased in intensity as the temperature increased, and 15 were variable depending on the excitation wavelength. Sulforhodamine B (monosodium salt) exhibited a fold change in fluorescence of 2.85. Faster PCR minimizes cycling times and improves turnaround time, throughput, and specificity. If temperature measurements are accurate, no holding period is required even at rapid speeds. A custom instrument using fluorescence-based temperature monitoring with dynamic feedback control for temperature cycling amplified a fragment surrounding rs917118 from genomic DNA in 3 min and 45 s using 35 cycles, allowing subsequent genotyping by high-resolution melting analysis. Gold-standard thermocouple readings and fluorescence-based temperature differences were 0.29 +/- 0.17 and 0.96 +/- 0.26 degrees C at annealing and denaturation, respectively. This new method for temperature cycling may allow faster speeds for PCR than currently considered possible. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [31] Polymerase chain reaction in microfluidic devices
    Ahrberg, Christian D.
    Manz, Andreas
    Chung, Bong Geun
    [J]. LAB ON A CHIP, 2016, 16 (20) : 3866 - 3884
  • [32] A Fluorescence-Based Array Screen for Transglutaminase Substrates
    Malesevic, Miroslav
    Migge, Andreas
    Hertel, Thomas C.
    Pietzsch, Markus
    [J]. CHEMBIOCHEM, 2015, 16 (08) : 1169 - 1174
  • [33] A continuous-flow polymerase chain reaction microchip with regional velocity control
    Li, SF
    Fozdar, DY
    Ali, MF
    Li, H
    Shao, DB
    Vykoukal, DM
    Vykoukal, J
    Floriano, PN
    Olsen, M
    McDevitt, JT
    Gascoyne, PRC
    Chen, SC
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (01) : 223 - 236
  • [34] Review on fluorescence-based planar waveguide biosensors
    Duveneck, GL
    [J]. ADVANCED MATERIALS AND OPTICAL SYSTEMS FOR CHEMICAL AND BIOLOGICAL DETECTION, 1999, 3858 : 59 - 71
  • [35] Printed Circuit Board-Based Polymerase Chain Reaction Chip
    Park, Chan-Young
    Kim, Jong-Dae
    Ku, Ja-Hun
    Kim, Yu-Seop
    Song, Hye-Jeong
    Kim, Jongwon
    [J]. SENSOR LETTERS, 2012, 10 (5-6) : 1197 - 1202
  • [36] Highly precisive digital polymerase chain reaction based on inkjet printer
    He, Xinning
    Weng, Beilu
    Benma, Lamu
    Zou, Yan
    Nakajima, Hizuru
    Zeng, Hulie
    [J]. MICROCHEMICAL JOURNAL, 2024, 204
  • [37] Polymerase Chain Reaction-Based Sex Identification in the Greater Roadrunner
    Santamaria, Carlos A.
    Kelley, Samuel
    Schulz, Gerral G.
    Ransom, Dean, Jr.
    Hurtado, Luis A.
    [J]. JOURNAL OF WILDLIFE MANAGEMENT, 2010, 74 (06) : 1395 - 1399
  • [38] Polymerase chain reaction-based assays for the diagnosis of human brucellosis
    Wang, Ying
    Wang, Zhanli
    Zhang, Yaxian
    Bai, Liyun
    Zhao, Yue
    Liu, Chunfang
    Ma, An
    Yu, Hui
    [J]. ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2014, 13
  • [39] Polymerase chain reaction-based serotyping of pathogenic bacteria in food
    Salazar, Joelle K.
    Wang, Yun
    Yu, Shuijing
    Wang, Hui
    Zhang, Wei
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 110 : 18 - 26
  • [40] Implantable fluorescence-based glucose sensor development
    Ibey, BL
    Yadavalli, VK
    Thomas, HR
    Rounds, RM
    Pishko, MV
    Coté, GL
    [J]. OPTICAL DIAGNOSTICS AND SENSING V, 2005, 5702 : 1 - 6