X-Ray Calc: A software for the simulation of X-ray reflectivity

被引:13
|
作者
Penkov, Oleksiy, V [1 ]
Kopylets, Igor A. [2 ]
Khadem, Mahdi [3 ]
Qin, Tianzuo [1 ]
机构
[1] Zhejiang Univ, ZJU UIUC Inst, Int Campus, Haining 314400, Peoples R China
[2] Natl Tech Univ KhPI, UA-61002 Kharkiv, Ukraine
[3] Yonsei Univ, Dept Mech Engn, Seoul 03722, South Korea
关键词
X-ray reflectivity; Grazing incidence X-ray reflectometry; Coatings; Simulation; Fitting; MULTILAYER MIRRORS; SCATTERING; COATINGS; FILMS;
D O I
10.1016/j.softx.2020.100528
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
X-Ray Calc is a fast and convenient tool for the simulation of X-ray reflectivity (XRR). The software was developed with the aim of simplification and acceleration of the XRR simulation through a user-friendly interface and optimized computation core. X-Ray Calc implements the recursive approach of calculation of XRR based on Fresnel equations and proposes special instruments for the modeling of periodical multilayer structures. X-Ray Calc computes XRR as a function of wavelength or grazing angle and can be used for the simulation of the performance of X-ray mirrors. Computer modeling and fitting to experimental grazing incidence X-ray reflectometry (GIXR) is a powerful tool. It could be used for a comprehensive analysis of the structure of single- and multi-component layered nanomaterials. This method allows for the obtaining of information about thickness, roughness, and density of individual layers in coatings by the fitting of the modeled GIXR to the experimental ones. (C) 2020 The Authors. Published by Elsevier B.V.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Kinematical limit in the theory of X-ray magnetic reflectivity
    Andreeva, M. A.
    Repchenko, Yu L.
    CRYSTALLOGRAPHY REPORTS, 2013, 58 (07) : 1037 - 1042
  • [22] Characterizing pattern structures using x-ray reflectivity
    Lee, Hae-Jeong
    Soles, Christopher L.
    Ro, Hyun Wook
    Kang, Shuhui
    Lin, Eric K.
    Karim, Alamgir
    Wu, Wen-Li
    Hines, D. R.
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXI, PTS 1-3, 2007, 6518
  • [23] A SOFTWARE SIMULATION TOOL DEDICATED TO THE DESIGN AND EVALUATION OF X-RAY BACKSCATTER SYSTEMS
    Rebuffel, V.
    Tabary, J.
    Rheinlaender, J.
    10TH EUROPEAN CONFERENCE ON NON-DESTRUCTIVE TESTING 2010 (ECNDT), VOLS 1-5, 2010, : 1218 - 1228
  • [24] Application of kinoform lens for X-ray reflectivity analysis
    Tiwari, M. K.
    Alianelli, L.
    Dolbnya, I. P.
    Sawhney, K. J. S.
    JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 : 237 - 242
  • [25] X-ray reflectivity study of hydrogen implanted silicon
    Dubcek, P.
    Pivac, B.
    Bernstorff, S.
    Corni, F.
    Tonini, R.
    Ottaviani, G.
    APPLIED SURFACE SCIENCE, 2006, 253 (01) : 283 - 286
  • [26] X-ray reflectivity from curved liquid interfaces
    Festersen, Sven
    Hrkac, Stjepan B.
    Koops, Christian T.
    Runge, Benjamin
    Dane, Thomas
    Murphy, Bridget M.
    Magnussen, Olaf M.
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 432 - 438
  • [27] Stability of thermoresponsive methylcellulose thin film: x-ray reflectivity study
    Innis-Samson, Vallerie Ann
    Sakurai, Kenji
    X-RAY SPECTROMETRY, 2009, 38 (05) : 376 - 381
  • [28] Surface and interface roughness estimations by X-ray reflectivity and RBS measurements
    Fujii, Y.
    Nakajima, K.
    Suzuki, M.
    Kimura, K.
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 (12-13) : 1208 - 1211
  • [29] X-ray system simulation software tools for radiology and radiography education
    Kengyelics, Stephen M.
    Treadgold, Laura A.
    Davies, Andrew G.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 93 : 175 - 183
  • [30] happyXTube: A software for the real-time X-ray tube simulation
    Chen, Yichu
    Yu, Wei
    Hu, Sanming
    Deng, Jing
    Chen, Xiao
    SOFTWAREX, 2025, 29