Impact of orthophosphate addition on biofilm development in drinking water distribution systems

被引:37
作者
Gouider, Mbarka [1 ]
Bouzid, Jalel [1 ]
Sayadi, Sami [2 ]
Montiel, Antoine [3 ]
机构
[1] Ecole Natl Ingn Sfax, Sfax, Tunisia
[2] Ctr Biotechnol Sfax, Lab Bioprocedes, Sfax, Tunisia
[3] Eau Paris, F-75014 Paris, France
关键词
Biofilm; Distribution network; Drinking water; Orthophosphate treatment; LEAD IMMOBILIZATION; HYDROXYAPATITE; DISINFECTION; PIPES;
D O I
10.1016/j.jhazmat.2009.01.128
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The contamination of the water distribution network results from fixed bacteria multiplication (biofilm) on the water pipe walls, followed by their detachment and their transport in the circulating liquid. The presence of biofilms in distribution networks can result in numerous unwanted problems for the user such as microbial contamination of the distributed water and deterioration of the network (bio-corrosion). For old networks, lead-containing plumbings can be a serious cause of worry for the consumer owing to the release of lead ions in the circulating water. Among the solutions considered to reduce the presence of lead in drinking water, the addition of orthophosphates constitutes an interesting alternative. However, the added orthophosphate may cause - even at low doses - additional microbial growth. The main objective of this study was to evaluate the impact of the orthophosphate treatment on the biofilm, development in the water supplied by the Joinville-le-Pont water treatment plant (Eau de Paris, France). For this purpose, a laboratory pilot plant was devised and connected to the considered water network. Two quantification methods for monitoring the biofilm formation were used: the enumeration on R2A agar and the determination of proteins. For the biofilm detachment operation, an optimization of the rinsing step was firstly conducted in order to distinguish between free and fixed biomass. The data obtained showed that there was a linear relation between both quantification methods. They also showed that, for the tested water, the bacterial densities were not affected by orthophosphate addition at a treatment rate of 1 mg PO43-/L. (C) 2009 Published by Elsevier B.V.
引用
收藏
页码:1198 / 1202
页数:5
相关论文
共 24 条
  • [11] LIU D, 1994, B ENVIRON CONTAM TOX, V53, P913
  • [12] Chlorine demand of biofilms in water distribution systems
    Lu, W
    Kiéné, L
    Lévi, Y
    [J]. WATER RESEARCH, 1999, 33 (03) : 827 - 835
  • [13] MATTHIEU L, 1998, T S M, V3, P37
  • [14] MATTHIEU L, 1992, REV SCI EAU, V5, P91
  • [15] Characterization of phase evolution during lead immobilization by synthetic hydroxyapatite
    Mavropoulosa, E
    Rocha, NCC
    Moreira, JC
    Rossi, AM
    Soares, GA
    [J]. MATERIALS CHARACTERIZATION, 2004, 53 (01) : 71 - 78
  • [16] Nakache F., 1996, Revue des Sciences de l'Eau, V9, P499
  • [17] Survival of Mycobacterium avium in a model distribution system
    Norton, CD
    LeChevallier, MW
    Falkinham, JO
    [J]. WATER RESEARCH, 2004, 38 (06) : 1457 - 1466
  • [18] Paquin J. L., 1992, Revue des Sciences de l'Eau, V5, P399
  • [19] REASONER DJ, 1985, APPL ENVIRON MICROB, V49, P1
  • [20] Formation of natural biofilms during chlorine dioxide and u.v. disinfection in a public drinking water distribution system
    Schwartz, T
    Hoffmann, S
    Obst, U
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2003, 95 (03) : 591 - 601