Effect of hemoglobin extinction spectra on optical spectroscopic measurements of blood oxygen saturation

被引:26
作者
Amelink, Arjen [1 ]
Christiaanse, Theo [1 ]
Sterenborg, Henricus J. C. M. [1 ]
机构
[1] Erasmus MC, Ctr Opt Diagnost & Therapy, Dept Radiat Oncol, NL-3000 CA Rotterdam, Netherlands
关键词
STATE DIFFUSE-REFLECTANCE; IN-VIVO; TISSUE; MODEL;
D O I
10.1364/OL.34.001525
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fiber-optic reflectance measurements were performed on scattering phantoms containing red blood cells. The oxygen pressure in the phantom was decreased by nitrogen gas bubbling, while carefully controlling and monitoring the temperature (37 degrees C) and pH (7.4). The blood oxygen saturation (SO2) was extracted from the optical spectroscopic measurements by fitting the spectra over the wavelength range of 350-850 nm to a model that includes the effects of pigment packaging, The effect of using different oxy- and deoxyhemoglobin extinction spectra on the quality and accuracy of the fits is analyzed. The optically extracted SO2 is Compared with the standard oxygen dissociation Curve (ODC). Depending on the choice of hemoglobin extinction spectra the absolute deviation between the ODC and the optically extracted SO2 is less than 2.5% over the measured range of saturations (4%-99%). (C) 2009 Optical Society of America
引用
收藏
页码:1525 / 1527
页数:3
相关论文
共 16 条
[1]   Non-invasive measurement of the morphology and physiology of oral mucosa by use of optical spectroscopy [J].
Amelink, A. ;
Kaspers, O. P. ;
Sterenborg, H. J. C. M. ;
van der Wal, J. E. ;
Roodenburg, J. L. N. ;
Witjes, M. J. H. .
ORAL ONCOLOGY, 2008, 44 (01) :65-71
[2]   In vivo measurement of the local optical properties of tissue by use of differential path-length spectroscopy [J].
Amelink, A ;
Sterenborg, HJCM ;
Bard, MPL ;
Burgers, SA .
OPTICS LETTERS, 2004, 29 (10) :1087-1089
[3]   Measurement of the local optical properties of turbid media by differential path-length spectroscopy [J].
Amelink, A ;
Sterenborg, HJCM .
APPLIED OPTICS, 2004, 43 (15) :3048-3054
[4]   Confidence intervals on fit parameters derived from optical reflectance spectroscopy measurements [J].
Amelink, Arjen ;
Robinson, Dominic J. ;
Sterenborg, Henricus J. C. M. .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (05)
[5]   A DIFFUSION-THEORY MODEL OF SPATIALLY RESOLVED, STEADY-STATE DIFFUSE REFLECTANCE FOR THE NONINVASIVE DETERMINATION OF TISSUE OPTICAL-PROPERTIES INVIVO [J].
FARRELL, TJ ;
PATTERSON, MS ;
WILSON, B .
MEDICAL PHYSICS, 1992, 19 (04) :879-888
[6]   Hemoglobin oxygen saturations in phantoms and in vivo from measurements of steady-state diffuse reflectance at a single, short source-detector separation [J].
Finlay, JC ;
Foster, TH .
MEDICAL PHYSICS, 2004, 31 (07) :1949-1959
[7]   Determination of optical properties of human blood in the spectral range 250 to 1100 nm using Monte Carlo simulations with hematocrit-dependent effective scattering phase function [J].
Friebel, Moritz ;
Roggan, Andre ;
Mueller, Gerhard ;
Meinke, Martina .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (03)
[8]   Empirical model description of photon path length for differential path length spectroscopy: combined effect of scattering and absorption [J].
Kanick, Stephen C. ;
Sterenborg, Henricus J. C. M. ;
Amelink, Arjen .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
[9]   Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms [J].
Palmer, GM ;
Ramanujam, N .
APPLIED OPTICS, 2006, 45 (05) :1062-1071
[10]   Analytical model of light reflectance for extraction of the optical properties in small volumes of turbid media [J].
Reif, Roberto ;
A'Amar, Ousama ;
Bigio, Irving J. .