Lymphoscintigraphy using technetium-99m human serum albumin in chylothorax

被引:10
作者
Stavngaard, T
Mortensen, J
Brenoe, J
Svendsen, LB
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Clin Physiol & Nucl Med, Copenhagen, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Dept Thorac Surg, Copenhagen, Denmark
[3] Copenhagen Univ Hosp, Rigshosp, Dept Gen Surg & Gastroenterol, Copenhagen, Denmark
关键词
lymphoscintigraphy; human serum albumin; chylothorax;
D O I
10.1055/s-2002-33099
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Chylous effusion is an infrequent complication of abdominothoracic surgery. When conservative therapy cannot cure the patient, surgical closure of the thoracic duct must be performed. If radiological lymphography is impossible to perform, lymphoscintigraphy with Tc-99m human serum albumin is a good alternative. Here, we present two patients who developed chylothorax after abdominothoracic surgery. Successful surgery was performed after lymphoscintigraphy had demonstrated the disruption of the thoracic duct.
引用
收藏
页码:250 / 252
页数:3
相关论文
共 4 条
[1]  
BAULIEU F, 1987, EUR J NUCL MED, V13, P264
[2]   Lymphoscintigraphy using Tc-99m human serum albumin in chylothorax [J].
Inoue, Y ;
Otake, T ;
Nishikawa, J ;
Sasaki, Y .
CLINICAL NUCLEAR MEDICINE, 1997, 22 (01) :60-60
[3]  
Kettner BI, 1998, J NUCL MED, V39, P2141
[4]   Preoperative and postoperative lymphoscintigraphy using Tc-99m sulfur colloid in the repair of a lymphatic leak in a patient with traumatic chylothorax [J].
Sun, SS ;
Tsai, SC ;
Hsu, NY ;
Shih, CS ;
Lee, JK ;
Kao, CH .
CLINICAL NUCLEAR MEDICINE, 2000, 25 (10) :840-841