Materials for medical applications form a huge market. in volume as well as in diversity. Depending on the specific application. different materials are used. For instance, in jaw and skull surgery the osseointegration behavior is the deciding factor, whereas for material in contact with blood, e.g. artificial heart valves the prevention of platelet adhesion and subsequent clotting is the main focus. Furthermore, mechanical properties like wear, hardness and elastic modulus can have an important influence on biocompatibility. In this review, the possibilities of plasma immersion ion implantation (Pill) for improving the biocompatibility of medical implants are shown. Specific examples for total hip replacements, titanium based osteosynthesis plates and carbon based heart valves are given. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:276 / 283
页数:8
相关论文
共 54 条
  • [1] ABABNEH M, 1998, P 1 TAG DVM ARB BIOW, P120
  • [2] Poor eight-year survival of cemented zirconia-polyethylene total hip replacements
    Allain, J
    Le Mouel, S
    Goutallier, D
    Voisin, MC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05): : 835 - 842
  • [3] Characterization of Ti-6Al-4V modified by nitrogen plasma immersion ion implantation
    Alonso, F
    Rinner, M
    Loinaz, A
    Onate, JI
    Ensinger, W
    Rauschenbach, B
    [J]. SURFACE & COATINGS TECHNOLOGY, 1997, 93 (2-3) : 305 - 308
  • [4] [Anonymous], 2000, Principles of Biochemistry
  • [5] Structure and composition of the titanium oxide layers formed by low-pressure oxidation of the Ni94Ti6(110) surface
    Atrei, A
    Bardi, U
    Rovida, G
    [J]. SURFACE SCIENCE, 1997, 391 (1-3) : 216 - 225
  • [6] BAURSCHMIDT P, 1977, J BIOENG, V1, P261
  • [7] HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS
    BERGMANN, G
    GRAICHEN, F
    ROHLMANN, A
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (08) : 969 - 990
  • [8] ARTIFICIAL-HEART VALVES - IMPROVED BLOOD COMPATIBILITY BY PECVD A-SIC-H COATING
    BOLZ, A
    SCHALDACH, M
    [J]. ARTIFICIAL ORGANS, 1990, 14 (04) : 260 - 269
  • [9] BREME J, 1998, TITAN TITANLEGIERUNG
  • [10] COMPARISON BETWEEN CONVENTIONAL AND PLASMA SOURCE ION-IMPLANTED FEMORAL KNEE COMPONENTS
    CHEN, A
    SCHEUER, JT
    RITTER, C
    ALEXANDER, RB
    CONRAD, JR
    [J]. JOURNAL OF APPLIED PHYSICS, 1991, 70 (11) : 6757 - 6760