Magnetic resonance only workflow and validation of dose calculations for radiotherapy of prostate cancer

被引:24
|
作者
Christiansen, Rasmus L. [1 ]
Jensen, Henrik R. [1 ]
Brink, Carsten [1 ,2 ]
机构
[1] Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark
[2] Univ Southern Denmark, Inst Clin Sci, Odense, Denmark
关键词
RADIATION-THERAPY; MRI SEQUENCES; SYSTEM; CT;
D O I
10.1080/0284186X.2017.1290275
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Current state of the art radiotherapy planning of prostate cancer utilises magnetic resonance (MR) for soft tissue delineation and computed tomography (CT) to provide an electron density map for dose calculation. This dual scan workflow is prone to setup and registration error. This study evaluates the feasibility of an MR-only workflow and the validity of dose calculation from an MR derived pseudo CT.Material and methods: Thirty prostate cancer patients were CT and MR scanned. Clinical treatment plans were generated on CT using a single 18MV arc volumetric modulated arc therapy (VMAT) with a prescription of 78Gy/39 fractions. Dose was recalculated on pseudo CT and assuming uniform water density. Pseudo CT and uniform density based dose calculations were compared to CT dose calculations by gamma analysis. One patient was treated with a plan based solely on MR and pseudo CT including daily image guided radiotherapy (IGRT) performed by manual match of implanted gold markers.Results: A pseudo CT was generated for 29 of the 30 patients. Median gamma pass rates for 1%/1mm passing criteria for dose calculated on pseudo CT when compared to CT were 100% for most evaluated structures. Dose calculated on uniform density also yielded high median pass rates, but with a higher occurrence of pass rates below 95%. Cases of pass rate below 95% on pseudo CT proved to originate from the presence of rectal air on CT, not represented by the pseudo CT. Treatment based on MR alone was successfully delivered to one patient, including manually performed daily IGRT.Conclusions: Median gamma pass rates were high for pseudo CT and proved superior to uniform density. Local differences in dose calculations were concluded not to have clinical relevance. Feasibility of the MR-only workflow was demonstrated through successful delivery of a treatment course planned based on MR alone.
引用
收藏
页码:787 / 791
页数:5
相关论文
共 50 条
  • [31] Functional Magnetic Resonance Imaging in Prostate Cancer
    Seitz, Michael
    Shukla-Dave, Amita
    Bjartell, Anders
    Touijer, Karim
    Sciarra, Alessandro
    Bastian, Patrick J.
    Stief, Christian
    Hricak, Hedvig
    Graser, Anno
    EUROPEAN UROLOGY, 2009, 55 (04) : 801 - 814
  • [32] The effects of motion on the dose distribution of proton radiotherapy for prostate cancer
    Qamhiyeh, Sima
    Geismar, Dirk
    Poettgen, Christoph
    Stuschke, Martin
    Farr, Jonathan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (03): : 3 - 11
  • [33] DOSE VERIFICATION IN RADIOTHERAPY OF PROSTATE CANCER PATIENTS WITH HIP PROSTHESIS
    Kieltyka, B.
    Rawojc, K.
    Kopec, R.
    Stanek, J.
    Truszkiewicz, A.
    Kisielewicz, K.
    ACTA PHYSICA POLONICA B PROCEEDINGS SUPPLEMENT, 2020, 13 (04) : 869 - 876
  • [34] Magnetic resonance image-based tomotherapy planning for prostate cancer
    Jung, Sang Hoon
    Kim, Jinsung
    Chung, Yoonsun
    Keserci, Bilgin
    Pyo, Hongryull
    Park, Hee Chul
    Park, Won
    RADIATION ONCOLOGY JOURNAL, 2020, 38 (01): : 52 - 59
  • [35] Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy
    Kim, Joshua
    Garbarino, Kim
    Schultz, Lonni
    Levin, Kenneth
    Movsas, Benjamin
    Siddiqui, M. Salim
    Chetty, Indrin J.
    Glide-Hurst, Carri
    RADIATION ONCOLOGY, 2015, 10
  • [36] Ablative Radiotherapy in Prostate Cancer: Stereotactic Body Radiotherapy and High Dose Rate Brachytherapy
    Ma, Ting Martin
    Lilleby, Oscar
    Lilleby, Wolfgang A.
    Kishan, Amar U.
    CANCERS, 2020, 12 (12) : 1 - 20
  • [37] Reducing the Toxicity of Radiotherapy for Pancreatic Cancer With Magnetic Resonance-guided Radiotherapy
    Tchelebi, Leila T.
    Zaorsky, Nicholas G.
    Rosenberg, Jennifer C.
    Sharma, Navesh K.
    Tuanquin, Leonard C.
    Mackley, Heath B.
    Ellis, Rodney J.
    TOXICOLOGICAL SCIENCES, 2020, 175 (01) : 19 - 23
  • [38] Postoperative radiotherapy for prostate cancer Morbidity of local-only or local-plus-pelvic radiotherapy
    Waldstein, Cora
    Doerr, Wolfgang
    Poetter, Richard
    Widder, Joachim
    Goldner, Gregor
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (01) : 23 - 30
  • [39] Point: Principles of Magnetic Resonance Imaging Integration in a Computed Tomography-Based Radiotherapy Workflow
    Brock, Kristy K.
    Dawson, Laura A.
    SEMINARS IN RADIATION ONCOLOGY, 2014, 24 (03) : 169 - 174
  • [40] Prostate Volume Changes during Extreme and Moderately Hypofractionated Magnetic Resonance Image-guided Radiotherapy
    Alexander, S. E.
    McNair, H. A.
    Oelfke, U.
    Huddart, R.
    Murray, J.
    Pathmanathan, A.
    Patel, P.
    Sritharan, K.
    van As, N.
    Tree, A. C.
    CLINICAL ONCOLOGY, 2022, 34 (09) : E383 - E391