Magnetic resonance only workflow and validation of dose calculations for radiotherapy of prostate cancer

被引:24
|
作者
Christiansen, Rasmus L. [1 ]
Jensen, Henrik R. [1 ]
Brink, Carsten [1 ,2 ]
机构
[1] Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark
[2] Univ Southern Denmark, Inst Clin Sci, Odense, Denmark
关键词
RADIATION-THERAPY; MRI SEQUENCES; SYSTEM; CT;
D O I
10.1080/0284186X.2017.1290275
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Current state of the art radiotherapy planning of prostate cancer utilises magnetic resonance (MR) for soft tissue delineation and computed tomography (CT) to provide an electron density map for dose calculation. This dual scan workflow is prone to setup and registration error. This study evaluates the feasibility of an MR-only workflow and the validity of dose calculation from an MR derived pseudo CT.Material and methods: Thirty prostate cancer patients were CT and MR scanned. Clinical treatment plans were generated on CT using a single 18MV arc volumetric modulated arc therapy (VMAT) with a prescription of 78Gy/39 fractions. Dose was recalculated on pseudo CT and assuming uniform water density. Pseudo CT and uniform density based dose calculations were compared to CT dose calculations by gamma analysis. One patient was treated with a plan based solely on MR and pseudo CT including daily image guided radiotherapy (IGRT) performed by manual match of implanted gold markers.Results: A pseudo CT was generated for 29 of the 30 patients. Median gamma pass rates for 1%/1mm passing criteria for dose calculated on pseudo CT when compared to CT were 100% for most evaluated structures. Dose calculated on uniform density also yielded high median pass rates, but with a higher occurrence of pass rates below 95%. Cases of pass rate below 95% on pseudo CT proved to originate from the presence of rectal air on CT, not represented by the pseudo CT. Treatment based on MR alone was successfully delivered to one patient, including manually performed daily IGRT.Conclusions: Median gamma pass rates were high for pseudo CT and proved superior to uniform density. Local differences in dose calculations were concluded not to have clinical relevance. Feasibility of the MR-only workflow was demonstrated through successful delivery of a treatment course planned based on MR alone.
引用
收藏
页码:787 / 791
页数:5
相关论文
共 50 条
  • [21] MR-PROTECT: Clinical feasibility of a prostate MRI-only radiotherapy treatment workflow and investigation of acceptance criteria
    Persson, Emilia
    Gustafsson, Christian Gustafsson
    Ambolt, Petra
    Engelholm, Silke
    Ceberg, Sofie
    Back, Sven
    Olsson, Lars E.
    Gunnlaugsson, Adalsteinn
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [22] Clinical use of magnetic resonance imaging across the prostate brachytherapy workflow
    Blanchard, P.
    Ménard, C.
    Frank, S. J.
    BRACHYTHERAPY, 2017, 16 (04) : 734 - 742
  • [23] Magnetic resonance imaging for delineation of prostate in radiotherapy: Monocentric experience and review of literature
    Auberdiac, P.
    Chargari, C.
    Negrier, F.
    Boutinaud, C.
    Zioueche, A.
    Cartier, L.
    Leduc, B.
    Dumas, J. -P.
    Colombeau, P.
    de Laroche, G.
    Magne, N.
    PROGRES EN UROLOGIE, 2012, 22 (03): : 159 - 165
  • [24] Applying a commercial atlas-based synthetic Computed Tomography algorithm to patients with hip prostheses for prostate Magnetic Resonance-only radiotherapy
    Wyatt, Jonathan
    McCallum, Hazel
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : 100 - 105
  • [25] Postoperative high-dose pelvic radiotherapy for N plus prostate cancer: Toxicity and matched case comparison with postoperative prostate bed-only radiotherapy
    Van Praet, Charles
    Ost, Piet
    Lumen, Nicolaas
    De Meerleer, Gert
    Vandecasteele, Katrien
    Villeirs, Geert
    Decaestecker, Karel
    Fonteyne, Valerie
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (02) : 222 - 228
  • [26] Application of an automated dose accumulation workflow in high-risk prostate cancer - validation and dose-volume analysis between planned and delivered dose
    Ong, Ashley
    Knight, Kellie
    Panettieri, Vanessa
    Dimmock, Mathew
    Tuan, Jeffrey Kit Loong
    Tan, Hong Qi
    Master, Zubin
    Wright, Caroline
    MEDICAL DOSIMETRY, 2022, 47 (01) : 92 - 97
  • [27] Dosimetric evaluation of synthetic CT for magnetic resonance-only based radiotherapy planning of lung cancer
    Wang, Hesheng
    Chandarana, Hersh
    Block, Kai Tobias
    Vahle, Thomas
    Fenchel, Matthias
    Das, Indra J.
    RADIATION ONCOLOGY, 2017, 12
  • [28] Planning magnetic resonance imaging for prostate cancer intensity-modulated radiation therapy: Impact on target volumes, radiotherapy dose and androgen deprivation administration
    Horsley, Patrick J.
    Aherne, Noel J.
    Edwards, Grace V.
    Benjamin, Linus C.
    Wilcox, Shea W.
    McLachlan, Craig S.
    Assareh, Hassan
    Welshman, Richard
    McKay, Michael J.
    Shakespeare, Thomas P.
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2015, 11 (01) : 15 - 21
  • [29] Prostate cancer: opportunities for magnetic resonance imaging
    Alyaev, Yu. G.
    Ternovoy, S. K.
    Bezrukov, E. A.
    Morozov, S. P.
    JOURNAL OF MENS HEALTH, 2008, 5 (01) : 11 - 17
  • [30] Personalized auto-segmentation for magnetic resonance imaging-guided adaptive radiotherapy of prostate cancer
    Chen, Xinyuan
    Ma, Xiangyu
    Yan, Xuena
    Luo, Fei
    Yang, Siran
    Wang, Zekun
    Wu, Runye
    Wang, Jianyang
    Lu, Ningning
    Bi, Nan
    Yi, Junlin
    Wang, Shulian
    Li, Yexiong
    Dai, Jianrong
    Men, Kuo
    MEDICAL PHYSICS, 2022, 49 (08) : 4971 - 4979