Magnetic resonance only workflow and validation of dose calculations for radiotherapy of prostate cancer

被引:24
|
作者
Christiansen, Rasmus L. [1 ]
Jensen, Henrik R. [1 ]
Brink, Carsten [1 ,2 ]
机构
[1] Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Odense, Denmark
[2] Univ Southern Denmark, Inst Clin Sci, Odense, Denmark
关键词
RADIATION-THERAPY; MRI SEQUENCES; SYSTEM; CT;
D O I
10.1080/0284186X.2017.1290275
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Current state of the art radiotherapy planning of prostate cancer utilises magnetic resonance (MR) for soft tissue delineation and computed tomography (CT) to provide an electron density map for dose calculation. This dual scan workflow is prone to setup and registration error. This study evaluates the feasibility of an MR-only workflow and the validity of dose calculation from an MR derived pseudo CT.Material and methods: Thirty prostate cancer patients were CT and MR scanned. Clinical treatment plans were generated on CT using a single 18MV arc volumetric modulated arc therapy (VMAT) with a prescription of 78Gy/39 fractions. Dose was recalculated on pseudo CT and assuming uniform water density. Pseudo CT and uniform density based dose calculations were compared to CT dose calculations by gamma analysis. One patient was treated with a plan based solely on MR and pseudo CT including daily image guided radiotherapy (IGRT) performed by manual match of implanted gold markers.Results: A pseudo CT was generated for 29 of the 30 patients. Median gamma pass rates for 1%/1mm passing criteria for dose calculated on pseudo CT when compared to CT were 100% for most evaluated structures. Dose calculated on uniform density also yielded high median pass rates, but with a higher occurrence of pass rates below 95%. Cases of pass rate below 95% on pseudo CT proved to originate from the presence of rectal air on CT, not represented by the pseudo CT. Treatment based on MR alone was successfully delivered to one patient, including manually performed daily IGRT.Conclusions: Median gamma pass rates were high for pseudo CT and proved superior to uniform density. Local differences in dose calculations were concluded not to have clinical relevance. Feasibility of the MR-only workflow was demonstrated through successful delivery of a treatment course planned based on MR alone.
引用
收藏
页码:787 / 791
页数:5
相关论文
共 50 条
  • [1] Synthetic computed tomography data allows for accurate absorbed dose calculations in a magnetic resonance imaging only workflow for head and neck radiotherapy
    Palmer, Emilia
    Karlsson, Anna
    Nordstrom, Fredrik
    Petruson, Karin
    Siversson, Carl
    Ljungberg, Maria
    Sohlin, Maja
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 17 : 36 - 42
  • [2] Geometric impact and dose estimation of on-patient placement of a lightweight receiver coil in a clinical magnetic resonance imaging-only radiotherapy workflow for prostate cancer
    Scherman, Jonas
    af Wetterstedt, Sacha
    Persson, Emilia
    Olsson, Lars E.
    Gustafsson, Christian Jamtheim
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26
  • [3] Magnetic resonance imaging for prostate cancer radiotherapy
    Dinh, Cuong V.
    Steenbergen, Peter
    Ghobadi, Ghazaleh
    Heijmink, Stijn W. T. J. P.
    Pos, Floris J.
    Haustermans, Karin
    van der Heide, Uulke A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (03): : 446 - 451
  • [4] Synthetic computed tomography based dose calculation in prostate cancer patients with hip prostheses for magnetic resonance imaging-only radiotherapy
    Koivula, Lauri
    Seppala, Tiina
    Collan, Juhani
    Visapaa, Harri
    Tenhunen, Mikko
    Korhonen, Arthur
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [5] Clinical experience and workflow challenges with magnetic resonance-only radiation therapy simulation and planning for prostate cancer
    Tyagi, Neelam
    Zelefsky, Michael J.
    Wibmer, Andreas
    Zakian, Kristen
    Burleson, Sarah
    Happersett, Laura
    Halkola, Aleksi
    Kadbi, Mo
    Hunt, Margie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 16 : 43 - 49
  • [6] Validation of the dosimetric and geometric accuracy of MR-only treatment planning solution for prostate cancer radiotherapy
    Posiewnik, Michal
    Piotrowski, Tomasz
    WSPOLCZESNA ONKOLOGIA-CONTEMPORARY ONCOLOGY, 2021, 25 (04): : 241 - 245
  • [7] Clinical implementation of magnetic resonance imaging guided adaptive radiotherapy for localized prostate cancer
    Tetar, Shyama U.
    Bruynzeel, Anna M. E.
    Lagerwaard, Frank J.
    Slotman, Ben J.
    Bohoudi, Omar
    Palacios, Miguel A.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 9 : 69 - 76
  • [8] Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis
    Edmund, Jens M.
    Andreasen, Daniel
    Van Leemput, Koen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 18 : 55 - 60
  • [9] Introducing magnetic resonance imaging into the lung cancer radiotherapy workflow - An assessment of patient experience
    Bellhouse, S.
    Brown, S.
    Dubec, M.
    Taylor, S.
    Hales, R.
    Whiteside, L.
    Yorke, J.
    Faivre-Finn, C.
    RADIOGRAPHY, 2021, 27 (01) : 14 - 23
  • [10] Findings on Diagnostic Magnetic Resonance Imaging Before Radiotherapy for Prostate Cancer
    Dahan, Johanna
    Delouya, Guila
    Lambert, Carole
    Olivie, Damien A. R.
    Billiard, Jean-Sebastien
    Taussky, Daniel
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2023, 74 (02): : 382 - 387