Experimental investigation of heat transfer coefficient of mini-channel PCHE (printed circuit heat exchanger)

被引:45
作者
Kwon, Dohoon [1 ]
Jin, Lingxue [1 ]
Jung, WooSeok [1 ]
Jeong, Sangkwon [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Sch Mech Aerosp & Syst Engn, Div Mech Engn, Cryogen Engn Lab, 291 Daehak Ro, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
Printed circuit heat exchanger (PCHE); Heat transfer coefficient; N-2 film boiling; CO2; condensation; THERMAL-HYDRAULIC PERFORMANCE; PHASE FORCED-CONVECTION; FLOW; MICROCHANNELS; LOOP;
D O I
10.1016/j.cryogenics.2018.03.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer coefficient of a mini-channel printed circuit heat exchanger (PCHE) with counter-flow configuration is investigated. The PCHE used in the experiments is two layered (10 channels per layer) and has the hydraulic diameter of 1.83 mm. Experiments are conducted under various cryogenic heat transfer conditions: single-phase, boiling and condensation heat transfer. Heat transfer coefficients of each experiments are presented and compared with established correlations. In the case of the single-phase experiment, empiricial correlation of modified Dittus-Boelter correlation was proposed, which predicts the experimental results with 5% error at Reynolds number range from 8500 to 17,000. In the case of the boiling experiment, film boiling phenomenon occurred dominantly due to large temperature difference between the hot side and the cold side fluids. Empirical correlation is proposed which predicts experimental results with 20% error at Reynolds number range from 2100 to 2500. In the case of the condensation experiment, empirical correlation of modified Akers correlation was proposed, which predicts experimental results with 10% error at Reynolds number range from 3100 to 6200.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 19 条
[1]   An experimental investigation of single-phase forced convection in microchannels [J].
Adams, TM ;
Abdel-Khalik, SI ;
Jeter, SM ;
Qureshi, ZH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (6-7) :851-857
[2]   Applicability of traditional turbulent single-phase forced convection correlations to non-circular microchannels [J].
Adams, TM ;
Dowling, MF ;
Abdel-Khalik, SI ;
Jeter, SM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (23) :4411-4415
[3]  
Akers W.W., 1958, Chem Eng Progr, V54
[4]   Development of highly effective cryogenic printed circuit heat exchanger (PCHE) with low axial conduction [J].
Baek, Seungwhan ;
Kim, Jin-Hyuck ;
Jeong, Sangkwon ;
Jung, Jeheon .
CRYOGENICS, 2012, 52 (7-9) :366-374
[5]  
BIPM I IFCC I IUPAC I, 1995, OIML 1995 GUID EXPR, V3
[6]  
Bowdery T, 2006, AICHE SPRING M 6 TOP
[7]  
Frank P. I., 2013, PRINCIPLEHEAT MASS
[8]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[9]  
Groeneveld D.C., 1973, Post-Dryout Heat Transfer at Reactor Operating Conditions
[10]   Partial flow compensation by transverse bypass configuration in multi-channel cryogenic compact heat exchanger [J].
Jung, Jeheon ;
Hwang, Gyuwan ;
Baek, Seungwhan ;
Jeong, Sangkwon ;
Rowe, Andrew M. .
CRYOGENICS, 2012, 52 (01) :19-26