Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study

被引:31
作者
Oborn, B. M. [1 ,2 ]
Ge, Y. [3 ]
Hardcastle, N. [4 ]
Metcalfe, P. E. [2 ,5 ]
Keall, P. J. [3 ,5 ]
机构
[1] ICCC, Wollongong, NSW 2500, Australia
[2] Univ Wollongong, CMRP, Wollongong, NSW 2500, Australia
[3] Univ Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia
[4] Royal N Shore Hosp, Northern Sydney Canc Ctr, St Leonards, NSW 2065, Australia
[5] Ingham Inst Appl Med Res, Liverpool, NSW 2170, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
lung dose enhancement; MRI guided radiotherapy; magnetic field; Monte Carlo; ELECTRON-BEAM THERAPY; PHOTON BEAMS; SURFACE ORIENTATION; AIR CAVITIES; MRI SCANNER; TRANSVERSE; ACCELERATOR; IMPACT; IMRT; DOSIMETRY;
D O I
10.1118/1.4938580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: A total of eight clinical lung tumor cases were recalculated using Monte Carlo methods, and external magnetic fields of 0.5, 1.0, and 3 T were included to observe the impact on dose to the planning target volume (PTV) and gross tumor volume (GTV). Three plans were 6 MV 3D-CRT plans while 6 were 6 MV IMRT. The GTV's ranged from 0.8 to 16 cm(3), while the PTV's ranged from 1 to 59 cm(3). In addition, the dose changes in a 30 cm diameter cylindrical water phantom were investigated for small beams. The central 20 cm of this phantom contained either water or lung density insert. Results: For single beams, an inline magnetic field of 1 T has a small impact in lung dose distributions by reducing the lateral scatter of secondary electrons, resulting in a small dose increase along the beam. Superposition of multiple small beams leads to significant dose enhancements. Clinically, this process occurs in the lung tissue typically surrounding the GTV, resulting in increases to the D-98% (PTV). Two isolated tumors with very small PTVs (3 and 6 cm3) showed increases in D-98% of 23% and 22%. Larger PTVs of 13, 26, and 59 cm(3) had increases of 9%, 6%, and 4%, describing a natural fall-off in enhancement with increasing PTV size. However, three PTVs bounded to the lung wall showed no significant increase, due to lack of dose enhancement in the denser PTV volume. In general, at 0.5 T, the GTV mean dose enhancement is around 60% lower than that at 1 T, while at 3 T, it is 5%-60% higher than 1 T. Conclusions: Monte Carlo methods have described significant and predictable dose enhancement effects in small lung tumor plans for 6 MV radiotherapy when an external inline magnetic field is included. Results of this study indicate that future clinical inline MRI-guided radiotherapy systems will be able to deliver a dosimetrically superior treatment to small (PTV < 15 cm(3)), isolated lung tumors over non-MRI-Linac systems. This increased efficacy coincides with the reimbursement in the United States of lung CT screening and the likely rapid growth in the number of patients with small lung tumors to be treated with radiotherapy. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:368 / 377
页数:10
相关论文
共 51 条
[1]  
[Anonymous], 2010, Journal of the ICRU, V10, DOI 10.1093/jicru/ndq001
[2]   THE EFFECT OF STRONG LONGITUDINAL MAGNETIC-FIELDS ON DOSE DEPOSITION FROM ELECTRON AND PHOTON BEAMS [J].
BIELAJEW, AF .
MEDICAL PHYSICS, 1993, 20 (04) :1171-1179
[3]   Compensating for the impact of non-stationary spherical air cavities on IMRT dose delivery in transverse magnetic fields [J].
Bol, G. H. ;
Lagendijk, J. J. W. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) :755-768
[4]   Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator [J].
Bol, G. H. ;
Hissoiny, S. ;
Lagendijk, J. J. W. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05) :1375-1385
[5]   POSSIBLE TECHNIQUES IN DIRECT-ELECTRON-BEAM TUMOR THERAPY [J].
BOSTICK, WH .
PHYSICAL REVIEW, 1950, 77 (04) :564-565
[6]   Magnetic confinement of electron and photon radiotherapy dose: A Monte Carlo simulation with a nonuniform longitudinal magnetic field [J].
Chen, Y ;
Bielajew, AF ;
Litzenberg, DW ;
Moran, JM ;
Becchetti, FD .
MEDICAL PHYSICS, 2005, 32 (12) :3810-3818
[7]   Modulation of radiotherapy photon beam intensity using magnetic field [J].
Chu, JCH ;
Reiffel, L ;
Hsi, WC ;
Saxena, VA .
INTERNATIONAL JOURNAL OF CANCER, 2001, 96 :131-137
[8]  
Chu JCH, 2000, P ANN INT IEEE EMBS, V22, P2737, DOI 10.1109/IEMBS.2000.901426
[9]   Depth dose enhancement of electron beams subject to external uniform longitudinal magnetic fields: A Monte Carlo study [J].
Earl, MA ;
Ma, L .
MEDICAL PHYSICS, 2002, 29 (04) :484-491
[10]   Improvement of dose distribution in breast radiotherapy using a reversible transverse magnetic field Linac-MR unit [J].
Esmaeeli, A. D. ;
Mahdavi, S. R. ;
Pouladian, M. ;
Monfared, A. S. ;
Bagheri, S. .
MEDICAL PHYSICS, 2014, 41 (01)