Glenohumeral arthroscopy portals established using an outside-in technique: Neurovascular anatomy at risk

被引:50
作者
Lo, IKY
Lind, CC
Burkhart, SS
机构
[1] Univ Texas, Ctr Hlth Sci, San Antonio Orthopaed Grp, San Antonio, TX USA
[2] Univ Texas, Ctr Hlth Sci, Dept Orthopaed Surg, San Antonio, TX USA
关键词
shoulder arthroscopy; glenohumeral joint; neurovascular structures;
D O I
10.1016/j.arthro.2004.04.057
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to examine the neurovascular structures at risk during placement of glenohumeral arthroscopy portals using an outside-in technique. Type of Study: Anatomic cadaveric study. Methods: Five fresh-frozen cadaveric specimens were used in this study. Each shoulder was mounted on a custom-designed apparatus allowing shoulder arthroscopy in a lateral decubitus position. The following portals were established using an outside-in technique and marked using an 18-gauge spinal needle: posterior, posterolateral, anterior, 5-o'clock, anterosupero-lateral, and Port of Wilmington. Each specimen was carefully dissected after the procedure, and the distance from each portal site to the adjacent relevant neurovascular structures (axillary nerve, musculocutaneous nerve, lateral cord of the brachial plexus, cephalic vein, and axillary artery) was measured using a precision caliper. Results: Except for the cephalic vein, all of the neurovascular structures were more than 20 mm away from all the portals evaluated. When creating either an anterior portal or a 5-o'clock position portal, the mean distance from the portal to the cephalic vein was 18.8 mm and 9.8 mm, respectively. In one anterior portal, a direct injury to the cephalic vein occurred. Conclusions: Our study suggests that shoulder arthroscopy portals placed in an outside-in fashion are unlikely to produce neurologic injury. However, the cephalic vein is at risk during placement of an anterior or 5-o'clock position portal, although probably with minimal subsequent patient morbidity. Placing portals in an outside-in fashion guarantees the correct angle of approach, with minimal risk to adjacent neurologic structures. Clinical Relevance: This study shows the safety of standard and accessory glenohumeral arthroscopy portals.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 24 条
[1]  
Bigliani L U, 1991, Orthop Rev, V20, P743
[2]   Shoulder injuries in overhead athletes - The "dead arm" revisited [J].
Burkhart, SS ;
Morgan, CD ;
Kibler, WB .
CLINICS IN SPORTS MEDICINE, 2000, 19 (01) :125-+
[3]   Clinical and anatomic considerations in the use of a new anterior inferior subaxillary nerve arthroscopy portal [J].
Burkhart, SS ;
Nassar, J ;
Schenck, RC ;
Wirth, MA .
ARTHROSCOPY, 1996, 12 (05) :634-637
[4]   Slap lesions in the overhead athlete (Reprinted from Operative Techniques in Sports Medicine, July, 2000) [J].
Burkhart, SS ;
Morgan, C .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (03) :431-+
[5]  
BURKHART SS, 2001, OPERAT TECH ORTHOP, V11, P17
[6]  
BURKHART SS, 2001, TECH SHOULDER ELBOW, V2, P74
[7]  
Cameron S E, 1996, J Shoulder Elbow Surg, V5, P404, DOI 10.1016/S1058-2746(96)80073-5
[8]  
Curtis AS, 1992, ARTHROSCOPY, V8, P395
[9]   ANTERIOR-INFERIOR (5-OCLOCK) PORTAL FOR SHOULDER ARTHROSCOPY [J].
DAVIDSON, PA ;
TIBONE, JE .
ARTHROSCOPY, 1995, 11 (05) :519-525
[10]   COMPUTABLE ERROR-BOUNDS FOR THE GENERALIZED SYMMETRIC EIGENPROBLEM [J].
MATTHIES, HG .
COMMUNICATIONS IN APPLIED NUMERICAL METHODS, 1985, 1 (01) :33-38