Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump

被引:28
作者
Al Hayek, Ayman A. [1 ]
Robert, Asirvatham A. [1 ]
Al Dawish, Mohamed A. [1 ]
机构
[1] Prince Sultan Mil Med City, Diabet Treatment Ctr, Dept Endocrinol & Diabet, POB 7897, Riyadh 11159, Saudi Arabia
关键词
Type; 1; diabetes; finger pricks; freestyle libre; satisfaction; glycemic control; hypoglycemia; self-testing; GLYCEMIC CONTROL; RISK-FACTORS; MULTICENTER; ADOLESCENTS; HYPOGLYCEMIA; FREQUENCY; CHILDREN; PEOPLE; LIFE; FEAR;
D O I
10.1177/1179551419861102
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To evaluate the different experience of freestyle libre and finger pricks on clinical characteristics and glucose monitoring satisfaction (GMS) in patients with type 1 diabetes (T1D) using insulin pump (IP). METHODS: A prospective study was carried out on 47 (aged 17-21 years) T1D. who used conventional finger-pricking method for self-testing the glucose. The experiments were conducted between March 2018 and September 2018. For carrying out the study, the flash glucose monitoring (FGM) sensors were placed on each participant. at the baseline visit. by a trained diabetes educator. Furthermore. to determine the total number of scans conducted during the study period, the respective ambulatory glucose profiles were generated by computing the data collected from the sensors. In addition, a trained interviewer handed over the GMS questionnaire to each patient. at the baseline and at 12 weeks of the study. RESULTS: In comparison to the baseline (finger pricks), various parameters such as: HbA1c (P= .042), hypoglycemia (P= .001), mean capillary glucose (P= .004), total daily insulin dose (P= .0001), percentage of bolus insulin (P= .0001), daily bolus frequency (P= .0001), and daily carbohydrates intake (P= .0001) showed a significant improvement at 12 weeks. Similarly, substantial augmentation was noticed. in the sub domains of GMS. that is, openness (P= .0001), emotional burden (P= .0001), behavioral burden (P= .0001). and trust (P= .0001) at 12 weeks as compared to baseline. Overall. total GMS score at baseline was 1.72 +/- 0.37, which increased up to 3.41 +/- 0.49 (P= .0001) in the time period of 12 weeks. The HbA1c (r(2) = 0.45), hypoglycemia (r(2)=0.58), and the mean number of FGM scans, exhibited a negative correlation, while GMS (r(2)= 0.52) and the mean number of FGM scans, exhibited a positive correlation. CONCLUSION: The frequency of hypoglycemia. HbA1c level. capillary glucose, daily carbohydrates intake decreased. while the total daily insulin dose, daily bolus insulin and total GMS score increased with the use of FGM scanning for 12 weeks.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Insulin Pump Combined with Flash Glucose Monitoring: A Therapeutic Option to Improve Glycemic Control in Severely Nonadherent Patients with Type 1 Diabetes
    Halbron, Marine
    Bourron, Olivier
    Andreelli, Fabrizio
    Ciangura, Cecile
    Jacqueminet, Sophie
    Popelier, Marc
    Bosquet, Frederic
    Rouanet, Stephanie
    Amouyal, Chloe
    Hartemann, Agnes
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (07) : 409 - 412
  • [22] Cutaneous adverse events in a randomized controlled trial of flash glucose monitoring among youth with type 1 diabetes mellitus
    Marsters, Brooke L.
    Boucher, Sara E.
    Galland, Barbara C.
    Wiltshire, Esko J.
    de Bock, Martin I.
    Tomlinson, Paul A.
    Rayns, Jenny
    MacKenzie, Karen E.
    Chan, Huan
    Wheeler, Benjamin J.
    PEDIATRIC DIABETES, 2020, 21 (08) : 1516 - 1524
  • [23] Budget Impact Analysis of the FreeStyle Libre Flash Continuous Glucose Monitoring -System® in Patients with Type 1 Diabetes Mellitus and Type 2 Diabetes Mellitus with Multiple Daily Insulin Injections in Argentina
    Palacios, Alfredo
    Rodriguez-Cairoli, Federico
    Balan, Dario
    Rojas-Roque, Carlos
    Moreno-Lopez, Carolina
    Braun, Barbara
    Augustovski, Federico
    Pichon-Riviere, Andres
    Bardach, Ariel
    APPLIED HEALTH ECONOMICS AND HEALTH POLICY, 2023, 21 (04) : 637 - 650
  • [24] Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes
    Vinals, Clara
    Quiros, Carmen
    Gimenez, Marga
    Conget, Ignacio
    DIABETES THERAPY, 2019, 10 (03) : 929 - 936
  • [25] Continuous glucose monitoring system during physical exercise in adolescents with type 1 diabetes
    Adolfsson, P.
    Nilsson, S.
    Lindblad, B.
    ACTA PAEDIATRICA, 2011, 100 (12) : 1603 - 1609
  • [26] Impact of flash glucose monitoring on glucose control and hospitalization in type 1 diabetes: A nationwide cohort study
    Tsur, Anat
    Cahn, Avivit
    Israel, Meirav
    Feldhamer, Ilan
    Hammerman, Ariel
    Pollack, Rena
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2021, 37 (01)
  • [27] Cost analysis of the flash monitoring system (FreeStyle Libre 2) in adults with type 1 diabetes mellitus
    Oyaguez, Itziar
    Merino-Torres, Juan Francisco
    Brito, Miguel
    Bellido, Virginia
    Cardona-Hernandez, Roque
    Gomez-Peralta, Fernando
    Morales-Perez, Francisco
    BMJ OPEN DIABETES RESEARCH & CARE, 2020, 8 (01)
  • [28] Cost-Effectiveness of the FreeStyle Libre(R) System Versus Blood Glucose Self-Monitoring in Individuals with Type 2 Diabetes on Insulin Treatment in Sweden
    Jendle, Johan
    Eeg-Olofsson, Katarina
    Svensson, Ann-Marie
    Franzen, Stefan
    Lamotte, Mark
    Levrat-Guillen, Fleur
    DIABETES THERAPY, 2021, 12 (12) : 3137 - 3152
  • [29] Clinical Utilities of Continuous Glucose Monitoring and Insulin Pumps in Pediatric Patients with Type 1 Diabetes
    Lee, Jieun
    Kim, Jae Hyun
    EWHA MEDICAL JOURNAL, 2021, 44 (03): : 55 - 62
  • [30] Flash Continuous Glucose Monitoring (FreeStyle Libre 14-Day System) for Self-Management of Diabetes Mellitus
    Choi, Hiu Ying Joanna
    AMERICAN FAMILY PHYSICIAN, 2021, 103 (11) : 688 - 690