Superior Vena Cava Perforation Following the Placement of a Superior Vena Cava Filter in Males Less than 60 Years of Age

被引:8
作者
Usoh, Fred [1 ]
Hingorani, Anil [1 ]
Ascher, Enrico [1 ]
Shiferson, Alexander [1 ]
Tran, Victor [1 ]
Patel, Nirav [1 ]
Marks, Natalie [1 ]
机构
[1] Maimonides Hosp, Div Vasc Surg, Dept Surg, Brooklyn, NY 11219 USA
关键词
filter; perforation; superior vena cava; upper extremity deep venous thrombosis; DEEP VENOUS THROMBOSIS; UPPER-EXTREMITY; GREENFIELD FILTERS; CLINICAL-EXPERIENCE;
D O I
10.2310/6670.2008.00076
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Although the utility of the superior vena cava (SVC) filter remains controversial, the safety and efficacy of SVC filters in patients with upper extremity deep venous thrombosis in whom anticoagulation is contraindicated or ineffective have been well described. However, few complications have been reported. Herein we describe a series of three cases of SVC perforation in three young males following the placement of SVC filters. All three patients had deep venous thrombosis on upper extremity duplex ultrasonography and contraindication to anticoagulation (n = 1) or failure of anticoagulation (n = 2). Cardiac tamponade was demonstrated on transthoracic echocardiography in all three cases. The pericardial effusion was evacuated with either median sternotomy or pericardiocentesis in two cases. One of the patients died of cardiac arrest, and an autopsy showed aortic perforation in addition to the SVC perforation. This patient underwent chest compression following the cardiac arrest. One patient was lost to follow-up, and the other patient remained asymptomatic at the 1-year follow-up. This is the first case of SVC perforation that is associated with aortic perforation after the placement of an SVC filter. Owing to this occurrence, one has to be aware of these life-threatening complications when placing an SVC filter, especially in males less than 60 years of age.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 26 条
  • [1] ABURAHMA AF, 1991, AM SURGEON, V57, P101
  • [2] Superior vena caval Greenfield filters: Indications, techniques, and results
    Ascer, E
    Gennaro, M
    Lorensen, E
    Pollina, RM
    [J]. JOURNAL OF VASCULAR SURGERY, 1996, 23 (03) : 498 - 503
  • [3] Ascher E, 1999, J ENDOVASC SURG, V6, P365, DOI 10.1583/1074-6218(1999)006<0365:CEWSVC>2.0.CO
  • [4] 2
  • [5] Lessons learned from a 6-year clinical experience with superior vena cava Greenfield filters
    Ascher, E
    Hingorani, A
    Tsemekhin, B
    Yorkovich, W
    Gunduz, Y
    [J]. JOURNAL OF VASCULAR SURGERY, 2000, 32 (05) : 881 - 886
  • [6] EFFORT THROMBOSIS OF THE AXILLARY VEIN WITH PULMONARY EMBOLISM
    BARNETT, T
    LEVITT, LM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1951, 146 (15): : 1412 - 1413
  • [7] UPPER EXTREMITY DEEP VENOUS THROMBOSIS - UNDERDIAGNOSED AND POTENTIALLY LETHAL
    BLACK, MD
    FRENCH, GJ
    RASULI, P
    BOUCHARD, AC
    [J]. CHEST, 1993, 103 (06) : 1887 - 1890
  • [8] CUGELL DW, 1994, JAMA-J AM MED ASSOC, V270, P1867
  • [9] LATE COMPLICATION OF A GREENFIELD FIL TER ASSOCIATING CAUDAL MIGRATION AND PERFORATION OF THE ABDOMINAL-AORTA BY A RUPTURED STRUT
    DABBAGH, A
    CHAKFE, N
    KRETZ, JG
    DEMRI, B
    NICOLINI, P
    FUENTES, C
    METTAUER, B
    EPAILLY, E
    MUSTER, D
    EISENMANN, B
    [J]. JOURNAL OF VASCULAR SURGERY, 1995, 22 (02) : 182 - 187
  • [10] DALEN JE, 1975, PROG CARDIOVASC DIS, V17, P257