An efficient new method for the detection of QRS in electrocardiogram

被引:71
作者
Dohare, Ashok Kumar [1 ]
Kumar, Vinod [1 ]
Kumar, Ritesh [2 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Roorkee 247667, Uttrakhand, India
[2] Rajendra Inst Med Sci, Dept Cardiol, Ranchi 834001, Jharkhand, India
关键词
ALGORITHM; COMPLEXES;
D O I
10.1016/j.compeleceng.2013.11.004
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
A simple and efficient new method for QRS detection in Electrocardiogram (ECG) is proposed in this paper. Initially data is preprocessed using two stage median filter for removing baseline drift. The second stage enhances the peaks of ECG wave components by using sixth power of signal. The next stage identifies the QRS complex by taking a variable window size. The detection sensitivity (Se) and positive predictivity (+P) of CSE (Common Standards for Quantitative Electrocardiography) measurement database, MIT/BIH (Massachusetts Institute of Technology/Beth Israel Hospital) Arrhythmia database, European ST-T database and QT database are Se 99.51 & +P 99.69%, Se 99.21 & +P 99.34%, Se 99.53 & +P 99.72% and Se 99.87 & +P 99.95% respectively. These four standard databases used to perform QRS detection considered 368 cases, tested 1,006,168 beats and achieved overall average sensitivity 99.52% and positive predictivity 99.69%. The MIT/BIH Noise Stress Test Database also tested by proposed method. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1717 / 1730
页数:14
相关论文
共 25 条
[1]   Development of QRS detection algorithm designed for wearable cardiorespiratory system [J].
Adnane, Mourad ;
Jiang, Zhongwei ;
Choi, Samjin .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 93 (01) :20-31
[2]   Analysis of first-derivative based QRS detection algorithms [J].
Arzeno, Natalia M. ;
Deng, Zhi-De ;
Poon, Chi-Sang .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) :478-484
[3]   A new QRS detection algorithm based on the Hilbert transform [J].
Benitez, DS ;
Gaydecki, PA ;
Zaidi, A ;
Fitzpatrick, AP .
COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 :379-382
[4]   A real-time QRS detection method based on moving-averaging incorporating with wavelet denoising [J].
Chen, Szi-Wen ;
Chen, Hsiao-Chen ;
Chan, Hsiao-Lung .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 82 (03) :187-195
[5]   QRS complex detection based on multi wavelet packet decomposition [J].
Chouakri, S. A. ;
Bereksi-Reguig, F. ;
Taleb-Ahmed, A. .
APPLIED MATHEMATICS AND COMPUTATION, 2011, 217 (23) :9508-9525
[6]   Real time electrocardiogram QRS detection using combined adaptive threshold [J].
Christov, Ivaylo I. .
BIOMEDICAL ENGINEERING ONLINE, 2004, 3 (1)
[7]   A COMPARISON OF THE NOISE SENSITIVITY OF 9 QRS DETECTION ALGORITHMS [J].
FRIESEN, GM ;
JANNETT, TC ;
JADALLAH, MA ;
YATES, SL ;
QUINT, SR ;
NAGLE, HT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :85-98
[8]   A robust wavelet-based multi-lead electrocardiogram delineation algorithm [J].
Ghaffari, A. ;
Homaeinezhad, M. R. ;
Akraminia, M. ;
Atarod, M. ;
Daevaeiha, M. .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (10) :1219-1227
[9]   A new mathematical based QRS detector using continuous wavelet transform [J].
Ghaffarl, A. ;
Golbayani, H. ;
Ghasemi, M. .
COMPUTERS & ELECTRICAL ENGINEERING, 2008, 34 (02) :81-91
[10]   QUANTITATIVE INVESTIGATION OF QRS DETECTION RULES USING THE MIT/BIH ARRHYTHMIA DATABASE [J].
HAMILTON, PS ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) :1157-1165