Biomechanics of Osteosynthesis in Periprosthetic Femoral Fractures Following Total Hip Arthroplasty

被引:0
作者
Skala-Rosenbaum, J. [1 ,2 ]
Dzupa, V [1 ,2 ]
Krbec, M. [1 ,2 ]
机构
[1] Univ Karlovy, Lekarske Fak, Ortopedickotraumatol Klin 3, Prague, Czech Republic
[2] Fak Nemocnice Kralovske Vinohrady, Prague, Czech Republic
关键词
hip joint; arthroplasty; periprosthetic fractures; biomechanics of osteosynthesis; FEMUR FRACTURES; PLATE FIXATION; SHAFT FRACTURES; EPIDEMIOLOGY; STABILITY; FAILURE; STEMS; SCREW;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Periprosthetic femoral fractures around the femoral stem of a hip prosthesis constitute a serious challenge. The number of these fractures, associated with a high failure rate and a high number of overall complications, including higher mortality, has been on an increase worldwide. Stable femoral stems are indicated for osteosynthesis, while in case of loosening the method of choice is the replacement by a revision implant. The aim of osteosynthesis of periprosthetic femoral fractures is a stable fixation with soft tissue preservation which results in faster union allowing the patient to return to pre-injury activities. Biomechanical studies on cadavers or on synthetic models and computer simulations make it possible to evaluate the fixation strength in various types of implants in dependence on fracture characteristics and bone quality, but cannot be substituted for clinical trials since there is no direct proportion between fixation rigidity and fracture union. Fundamental principles that shall be followed in osteosynthesis of periprosthetic fractures can be deduced from the available studies. Proximal fixation by screws or a combination of screws and cables are biomechanically more advantageous than the Ogden fixation by cerclage wires or cables. Bicortical fixation enabled by state-of-the-art implants of LAP-LCP or NCB type represents a significantly more stable construction compared to monocortical fixation and led to reduced use of structural allografts. Better stability can be achieved by "double plating" technique which is applied especially in revision surgeries, but also in osteoporotic periprosthetic fractures with a defect zone. In these cases, osteosynthesis with long plates is recommended, bridging the entire femur, i.e. distally with femoral condyles fixation since this prevents the risk of a fracture below the plate. In shorter plates, this risk created by stress concentration at the end screw is amplified when a distal bicortical locking screw is used. That is why it is beneficial to reduce this stress by a monocortical screw or with the use of a conventional screw. Adherence to the principles regarding the position, type and number of screws constitutes the key parameter of successful osteosynthesis of periprosthetic fractures.
引用
收藏
页码:309 / 317
页数:9
相关论文
共 41 条
[1]   Epidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties [J].
Abdel, M. P. ;
Houdek, M. T. ;
Watts, C. D. ;
Lewallen, D. G. ;
Berry, D. J. .
BONE & JOINT JOURNAL, 2016, 98B (04) :468-474
[2]   Biomechanical evaluation of periprosthetic refractures following distal femur locking plate fixation [J].
Alexander, Jamie ;
Morris, Randal P. ;
Kaimrajh, David ;
Milne, Edward ;
Latta, Loren ;
Flink, Adam ;
Lindsey, Ronald W. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (12) :2368-2373
[3]   A Nonlocking End Screw Can Decrease Fracture Risk Caused by Locked Plating in the Osteoporotic Diaphysis [J].
Bottlang, Michael ;
Doornink, Josef ;
Byrd, Gregory D. ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03) :620-627
[4]   Inflammatory Laboratory Markers in Periprosthetic Hip Fractures [J].
Chevillotte, Christophe J. ;
Ali, Mir H. ;
Trousdale, Robert T. ;
Larson, Dirk R. ;
Gullerud, Rachel E. ;
Berry, Daniel J. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (05) :722-727
[5]   A retrospective review of the Dall-Miles plate for periprosthetic femoral fractures: Twenty-seven cases and a review of the literature [J].
Dargan, Dallan ;
Jenkinson, Mark J. ;
Acton, Joseph D. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (12) :1958-1963
[6]  
Dehghan N, 2014, J ORTHOP TRAUMA, V28, P721, DOI 10.1097/BOT.0000000000000126
[7]   Fixation of periprosthetic femoral shaft fractures: A biomechanical comparison of two techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
Di Cesare, PE .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) :177-180
[8]   Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :523-528
[9]   The Unified Classification System (UCS): improving our understanding of periprosthetic fractures [J].
Duncan, C. P. ;
Haddad, F. S. .
BONE & JOINT JOURNAL, 2014, 96B (06) :713-716
[10]  
Duncan CP, 1995, AAOS INSTR COURS LEC, V44, P293