Use of Ultrathin Bronchoscope on a Need Basis Improves Diagnostic Yield of Difficult-to-Approach Pulmonary Lesions

被引:11
作者
Nishii, Yoichi [1 ]
Nakamura, Yuki [1 ]
Fujiwara, Kentaro [1 ]
Ito, Kentaro [1 ]
Sakaguchi, Tadashi [1 ]
Suzuki, Yuta [1 ]
Furuhashi, Kazuki [1 ]
Kobayashi, Tetsu [2 ]
Yasuma, Taro [3 ]
D'Alessandro-Gabazza, Corina N. [3 ]
Gabazza, Esteban C. [3 ]
Asano, Fumihiro [4 ]
Taguchi, Osamu [1 ]
Hataji, Osamu [1 ]
机构
[1] Matsusaka Municipal Hosp, Resp Ctr, Matsusaka, Japan
[2] Mie Univ, Dept Pulm & Crit Care Med, Fac & Grad Sch Med, Tsu, Mie, Japan
[3] Mie Univ, Dept Immunol, Fac & Grad Sch Med, Tsu, Mie, Japan
[4] Gifu Prefectural Gen Med Ctr, Gifu, Japan
关键词
ultrathin bronchoscope; peripheral pulmonary lesion; diagnostic bronchoscopy; endobronchial ultrasound; thin bronchoscope; ENDOBRONCHIAL ULTRASONOGRAPHY; GUIDE SHEATH; BIOPSY; ULTRASOUND;
D O I
10.3389/fmed.2020.588048
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There are cases of peripheral lung nodules that are difficult to approach despite using ancillary diagnostic devices during multimodal bronchoscopy. The use of ultrathin bronchoscopes has shown superiority over standard thin bronchoscopes. We retrospectively evaluated whether substitution of the thin-bronchoscope by the ultrathin device during multimodal bronchoscopy improves lesion ultrasound visualization and diagnostic yield in patients with difficult-to-approach pulmonary lesions. The study comprised 44 out of 338 patients that underwent multimodal bronchoscopy at Matsusaka Municipal Hospital. The thin-bronchoscope with an external diameter of 4 mm was substituted by the ultrathin-bronchoscope with an external diameter of 3 mm when the radial endobronchial ultrasound showed that the probe position was not within the target lesion. The median diameter of the pulmonary tumors was 17.5 mm (range: 6.0-5.2.0 mm). The endobronchial ultrasound showed the probe's position adjacent to the lesion in 12 cases and no visible lesion in 32 cases using a thin-bronchoscope. However, the endobronchial ultrasound views changed from adjacent to the lesion to within the lesion in nine cases, from no visible lesion to within the lesion in 17 cases, and from no visible lesion to adjacent to the lesion in nine cases after bronchoscope substitution. After substitution, the diagnostic yield was 80.8% in cases with the radial probe within the target lesion, 72.7% in cases with the probe adjacent to the target lesion, and 0% in cases with no visible lesion. The overall diagnostic yield was 65.9% after bronchoscope substitution. The substitution of the thin bronchoscope by the ultrathin device on a need basis improves the position of the radial endobronchial ultrasound probe and diagnostic yield of pulmonary lesions during multimodal diagnostic bronchoscopy.
引用
收藏
页数:7
相关论文
共 15 条
[1]   A virtual bronchoscopic navigation system for pulmonary peripheral lesions [J].
Asano, Fumihiro ;
Matsuno, Yoshihiko ;
Shinagawa, Naofumi ;
Yamazaki, Koichi ;
Suzuki, Toshitaka ;
Ishida, Takashi ;
Moriya, Hiroshi .
CHEST, 2006, 130 (02) :559-566
[2]   Virtual Bronchoscopic Navigation Combined with Ultrathin Bronchoscopy A Randomized Clinical Trial [J].
Asano, Fumihiro ;
Shinagawa, Naofumi ;
Ishida, Takashi ;
Shindoh, Joe ;
Anzai, Masaki ;
Tsuzuku, Akifumi ;
Oizumi, Satoshi ;
Morita, Satoshi .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 188 (03) :327-333
[3]   Virtual bronchoscopic navigation combined with endobronchial ultrasound to diagnose small peripheral pulmonary lesions: a randomised trial [J].
Ishida, Takashi ;
Asano, Fumihiro ;
Yamazaki, Koichi ;
Shinagawa, Naofumi ;
Oizumi, Satoshi ;
Moriya, Hiroshi ;
Munakata, Mitsuru ;
Nishimura, Masaharu .
THORAX, 2011, 66 (12) :1072-1077
[4]   Novel bronchofiberscopic catheter spray device allows effective anesthetic spray and sputum suctioning [J].
Kenzaki, K ;
Hirose, Y ;
Tamaki, M ;
Sakiyama, S ;
Kondo, K ;
Mutsuda, T ;
Monden, Y .
RESPIRATORY MEDICINE, 2004, 98 (07) :606-610
[5]   Diagnostic utility of additional conventional techniques after endobronchial ultrasonography guidance during transbronchial biopsy [J].
Kunimasa, Kei ;
Tachihara, Motoko ;
Tamura, Daisuke ;
Tokunaga, Shuntaro ;
Nakata, Kyosuke ;
Hazeki, Nobuko ;
Kamiryo, Hiroshi ;
Kobayashi, Kazuyuki ;
Sakai, Yasuhiro ;
Nishimura, Yoshihiro .
RESPIROLOGY, 2016, 21 (06) :1100-1105
[6]   Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically [J].
Kurimoto, N ;
Miyazawa, T ;
Okimasa, S ;
Maeda, A ;
Oiwa, H ;
Miyazu, Y ;
Murayama, M .
CHEST, 2004, 126 (03) :959-965
[7]   Factors leading to failure to diagnose pulmonary malignant tumors using endobronchial ultrasound with guide sheath within the target lesion [J].
Nishii, Yoichi ;
Yasuma, Taro ;
Ito, Kentaro ;
Suzuki, Yuta ;
Watanabe, Fumiaki ;
Kobayashi, Tetsu ;
Nishihama, Kota ;
D'Alessandro-Gabazza, Corina N. ;
Fujimoto, Hajime ;
Gabazza, Esteban C. ;
Asano, Fumihiro ;
Taguchi, Osamu ;
Hataji, Osamu .
RESPIRATORY RESEARCH, 2019, 20 (01)
[8]   Use of an Ultrathin vs Thin Bronchoscope for Peripheral Pulmonary Lesions A Randomized Trial [J].
Oki, Masahide ;
Saka, Hideo ;
Asano, Fumihiro ;
Kitagawa, Chiyoe ;
Kogure, Yoshihito ;
Tsuzuku, Akifumi ;
Ando, Masahiko .
CHEST, 2019, 156 (05) :954-964
[9]   Ultrathin Bronchoscopy with Multimodal Devices for Peripheral Pulmonary Lesions A Randomized Trial [J].
Oki, Masahide ;
Sakai, Hideo ;
Ando, Masahiko ;
Asano, Fumihiro ;
Kurimoto, Noriaki ;
Morita, Katsuhiko ;
Kitagawa, Chiyoe ;
Kogure, Yoshihito ;
Miyazawa, Teruomi .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 192 (04) :468-476
[10]   Establishing the Diagnosis of Lung Cancer Diagnosis and Management of Lung Cancer, 3rd ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines [J].
Rivera, M. Patricia ;
Mehta, Atul C. ;
Wahidi, Momen M. .
CHEST, 2013, 143 (05) :E142-E165