X-Ray Computed Tomography Through Scatter

被引:5
|
作者
Geva, Adam [1 ]
Schechner, Yoav Y. [1 ]
Chernyak, Yonatan [1 ]
Gupta, Rajiv [2 ]
机构
[1] Technion Israel Inst Technol, Viterbi Fac Elect Engn, Haifa, Israel
[2] Harvard Med Sch, Massachusetts Gen Hosp, Boston, MA 02115 USA
来源
关键词
CT; Xray; Inverse problem; Elastic/inelastic scattering; IMPLEMENTATION; DIFFRACTION; SIMULATION; MEDIA; TOOL; ART;
D O I
10.1007/978-3-030-01264-9_3
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In current Xray CT scanners, tomographic reconstruction relies only on directly transmitted photons. The models used for reconstruction have regarded photons scattered by the body as noise or disturbance to be disposed of, either by acquisition hardware (an anti-scatter grid) or by the reconstruction software. This increases the radiation dose delivered to the patient. Treating these scattered photons as a source of information, we solve an inverse problem based on a 3D radiative transfer model that includes both elastic (Rayleigh) and inelastic (Compton) scattering. We further present ways to make the solution numerically efficient. The resulting tomographic reconstruction is more accurate than traditional CT, while enabling significant dose reduction and chemical decomposition. Demonstrations include both simulations based on a standard medical phantom and a real scattering tomography experiment.
引用
收藏
页码:37 / 54
页数:18
相关论文
共 50 条
  • [1] THE EFFECTS OF SCATTER IN X-RAY COMPUTED-TOMOGRAPHY
    JOSEPH, PM
    SPITAL, RD
    MEDICAL PHYSICS, 1982, 9 (04) : 464 - 472
  • [2] Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography
    Vernekohl, Don
    Tzoumas, Stratis
    Zhao, Wei
    Xing, Lei
    MEDICAL PHYSICS, 2018, 45 (08) : 3741 - 3748
  • [3] Coherent scatter X-ray computed tomography in medical applications
    Schlomka, JP
    Harding, A
    Harding, G
    van Stevendaal, U
    Grass, A
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 900 - 901
  • [4] Incoherent scatter computed tomography with monochromatic synchrotron x-ray
    Yuasa, T
    Takeda, T
    Akiba, M
    Kazama, M
    Hoshino, A
    Watanabe, Y
    Hyodo, K
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 728 - 729
  • [5] X-ray scatter correction method for dedicated breast computed tomography
    Sechopoulos, Ioannis
    MEDICAL PHYSICS, 2012, 39 (05) : 2896 - 2903
  • [6] An X-Ray Scatter Correction Method for Dedicated Breast Computed Tomography
    Sechopoulos, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3914 - 3914
  • [7] Scatter Corrections in X-Ray Computed Tomography: A Physics-Based Analysis
    Levine, Zachary H.
    Blattner, Timothy J.
    Peskin, Adele P.
    Pintar, Adam L.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2019, 124
  • [8] Novel concept for coherent scatter X-ray computed tomography in medical applications
    Schlomka, JP
    Schneider, SM
    Harding, G
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 218 - 224
  • [9] X-ray scatter correction for multi- source interior computed tomography
    Gong, Hao
    Yan, Hao
    Jia, Xun
    Li, Bin
    Wang, Ge
    Cao, Guohua
    MEDICAL PHYSICS, 2017, 44 (01) : 71 - 83
  • [10] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41