Bedside ultrasound diagnosis of a malpositioned central venous catheter A case report

被引:2
作者
Song, Feier [1 ]
Huang, Daozheng [2 ]
Chen, Ying [2 ]
Xiao, Zhiyuan [3 ]
Su, Ke [4 ]
Wen, Jianyi [2 ]
Guo, Weixin [2 ]
Wang, Zhonghua [2 ]
Wu, Yan [2 ]
Wang, Shouhong [2 ]
Qin, Tiehe [2 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Gen Hosp, Guangdong Cardiovasc Inst, Dept Cardiol, Guangzhou, Guangdong, Peoples R China
[2] Guangdong Acad Med Sci, Guangdong Gen Hosp, Guangdong Geriatr Inst, Dept Crit Care Med, Guangzhou, Guangdong, Peoples R China
[3] Yunnan Canc Hosp, Dept Crit Care Med, Guangzhou, Guangdong, Peoples R China
[4] Zhongshan Dongsheng Hosp, Dept Crit Care Med, Guangzhou, Guangdong, Peoples R China
关键词
bedside ultrasound; central venous catheter; malposition; CRITICALLY-ILL PATIENTS; COMPLICATIONS; VEIN; PNEUMOTHORAX; METAANALYSIS; PREVENTION; PLACEMENT; GUIDANCE; LINE;
D O I
10.1097/MD.0000000000010501
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rationale: Central venous catheter (CVC) placement is commonly performed in intensive care unit. And CVC placement is associated with risks including CVC malposition, pneumothorax. Many of the previously reported cases are about catheter misplacement detected by bedside ultrasound, chest x-ray (CXR) and computed tomography. In this case, malposition was detected by bedside ultrasound incidentally particularly with no clinical manifestation. Patient concerns: An 88-year-old male with severe diabetic peripheral neuropathy secondary to type 2 diabetes mellitus was admitted for further treatment. Diagnoses: We cannulated a single-lumen CVC via the right subclavian vein, and the tip ended up in the internal jugular vein on the same side. With bedside ultrasound, we discovered the malposition though it was mistaken by aspiration of venous blood. Later, CXR revealed malposition of the tip once again. Interventions: Since the patient was asymptomatic and the catheter was functioning normally, the catheter was used for the following 20 days without complications. Ultimately, we carefully performed the catheter removal. Outcomes: After the inserted catheter was removed, we attempted a new CVC through the left internal jugular vein. After the procedure, bedside ultrasound and CXR confirmed the correct position of CVC. Following successful replacement of the central catheter, no further complications were observed. Lessons: Bedside ultrasound offers safety and effectiveness during insertion of CVC. It also exhibits promptness and accuracy compared to post-intervention radiological imaging.
引用
收藏
页数:5
相关论文
共 20 条
[1]   Diagnostic Accuracy of Central Venous Catheter Confirmation by Bedside Ultrasound Versus Chest Radiography in Critically III Patients: A Systematic Review and Meta-Analysis [J].
Ablordeppey, Enyo A. ;
Drewry, Anne M. ;
Beyer, Alexander B. ;
Theodoro, Daniel L. ;
Fowler, Susan A. ;
Fuller, Brian M. ;
Carpenter, Christopher R. .
CRITICAL CARE MEDICINE, 2017, 45 (04) :715-724
[2]   Comparison of routine chest radiograph versus clinician judgment to determine adequate central line placement in critically ill patients [J].
Abood, Gerard J. ;
Davis, Kimberly A. ;
Esposito, Thomas J. ;
Luchette, Fred A. ;
Gamelli, Richard L. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (01) :50-56
[3]   Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis [J].
Alrajab, Saadah ;
Youssef, Asser M. ;
Akkus, Nuri I. ;
Caldito, Gloria .
CRITICAL CARE, 2013, 17 (05)
[4]   Emergency Physician Perspectives on Central Venous Catheterization in the Emergency Department: A Survey-based Study [J].
Ballard, Dustin W. ;
Reed, Mary E. ;
Rauchwerger, Adina S. ;
Chettipally, Uli K. ;
Offerman, Steven R. ;
Mark, Dustin G. ;
Vinson, David R. .
ACADEMIC EMERGENCY MEDICINE, 2014, 21 (06) :623-630
[5]   Azygos arch cannulation by central venous catheters: Radiographic detection of malposition and subsequent complications [J].
Bankier, AA ;
Mallek, R ;
Wiesmayr, MN ;
Fleischmann, D ;
Kranz, A ;
Kontrus, M ;
Knapp, S ;
Winkelbauer, FW .
JOURNAL OF THORACIC IMAGING, 1997, 12 (01) :64-69
[6]   An unseen danger: Frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance [J].
Blaivas, Michael ;
Adhikari, Srikar .
CRITICAL CARE MEDICINE, 2009, 37 (08) :2345-2349
[7]   Value of high-resolution ultrasound in detecting a pneumothorax [J].
Chung, MJ ;
Goo, JM ;
Im, JG ;
Cho, JM ;
Cho, SB ;
Kim, SJ .
EUROPEAN RADIOLOGY, 2005, 15 (05) :930-935
[8]  
Ebrahimi Ali, 2014, Tanaffos, V13, P29
[9]   Ultrasound diagnosis of occult pneumothorax [J].
Lichtenstein, DA ;
Mezière, G ;
Lascols, N ;
Biderman, P ;
Courret, JP ;
Gepner, A ;
Goldstein, I ;
Tenoudji-Cohen, M .
CRITICAL CARE MEDICINE, 2005, 33 (06) :1231-1238
[10]   Lung ultrasound in the critically ill [J].
Lichtenstein, Daniel A. .
ANNALS OF INTENSIVE CARE, 2014, 4 :1-12