Aerodynamic sizing of metered dose inhalers: An evaluation of the Andersen and next generation pharmaceutical impactors and their, USP methods

被引:29
作者
Kamiya, A [1 ]
Sakagami, M [1 ]
Hindle, M [1 ]
Byron, PR [1 ]
机构
[1] Virginia Commonwealth Univ, Sch Pharm, Dept Pharmaceut, Richmond, VA 23298 USA
关键词
aerodynamic diameter; aerosols; bioequivalence; cascade impactor; formulation; metered dose inhaler; particle size; regulatory science; silicone coating; USP;
D O I
10.1002/jps.20091
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The particle sizing performance of a Next Generation Pharmaceutical Impactor (NGI) was compared to that of an Andersen cascade impactor (ACI). A single lot of Vanceril(R) MDIs containing beclomethasone dipropionate (BDP) was used throughout. MDIs were sampled into NGI and ACI in accordance with USP recommendations, at 30.0 and 28.3 L/min, respectively, following 1, 2,6, and 30 actuations with or without a silicone cup or stage coating, to determine the apparent particle size distributions (PSD) of BDP. The mass balance and the statistical comparability of drug deposits were assured on a "per actuation basis" across all experiments, demonstrating "good cascade impactor practices."Interstage deposition or "wall losses" in NGI were found to be lower than those in ACI, although their determination was laborious in NGI. The PSD profiles for Vanceril(C), from a single actuation were distinguishable between NGI and ACI, when uncoated collection surfaces were used, most specifically for drug mass <4-mum aerodynamic diameter (p < 0.05). Silicone coating of collection surfaces and an increased number of actuations were shown to result in PSD profile shifts for both NGI and ACI. Such effects were most pronounced for NGI, although coating the collection surfaces and/or increasing the number of actuations improved. drug retention significantly on the upper stages of NGI, and thereby, minimized the effects of particle bounce of BDP from Vanceril(R) MDIs. PSD profiles from a single actuation could be determined reliably in either of these impactors, provided that coated collection surfaces were employed; also, cumulative % mass undersize profiles Were similar between instruments. However, small differences in PSD profiles still existed to support NGI's design claims for reduced "overlap" in its stage collection efficiency curves. (C) 2004 Wiley-Liss, Inc. and the American Pharmacists Association.
引用
收藏
页码:1828 / 1837
页数:10
相关论文
共 24 条
[1]  
Allen T, 1981, PARTICLE SIZE ANAL, V3rd
[2]  
[Anonymous], 2003, USP 26-NF21, P2105
[3]   OPTIMIZED INHALATION AEROSOLS .1. THE EFFECTS OF SPHERICAL BAFFLE SIZE AND POSITION UPON THE OUTPUT OF SEVERAL PRESSURIZED NONAQUEOUS SUSPENSION FORMULATIONS [J].
BYRON, PR ;
DALBY, RN ;
HICKEY, AJ .
PHARMACEUTICAL RESEARCH, 1989, 6 (03) :225-229
[4]  
BYRON PR, 2002, RESP DRUG DELIVERY, V8, P145
[5]   PARTICLE BOUNCE IN CASCADE IMPACTORS [J].
CHENG, YS ;
YEH, HC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1979, 13 (11) :1392-1396
[6]   Considerations for the development and practice of cascade impaction testing, including a mass balance failure investigation tree [J].
Christopher, D ;
Curry, P ;
Doub, B ;
Furnkranz, K ;
Lavery, M ;
Lin, K ;
Lyapustina, S ;
Mitchell, J ;
Rogers, B ;
Strickland, H ;
Tougas, T ;
Tsong, Y ;
Wyka, B .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2003, 16 (03) :235-247
[7]  
CLARK AR, 2000, RESP DRUG DELIVERY, V7, P145
[8]   CAPTURE OF AEROSOL PARTICLES BY SURFACES [J].
DAHNEKE, B .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1971, 37 (02) :342-&
[9]  
European Pharmacopeia, 2001, PEP INH AER ASS FIN, P113
[10]   Influence of single versus multiple actuations on the particle size distribution of beclometasone dipropionate metered-dose inhalers [J].
Feddah, MR ;
Davies, NM .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2003, 55 (08) :1055-1061